Seleccione su país

Visite el sitio web global

NO DISPONIBLE PARA VENTA

CMCM Corrosion Monitoring CorrTran MV

Ventajas clave de un vistazo

  • Please see Metal Samples for purchase: http://www.alspi.com
  • On-line corrosion monitoring, multivariable
  • 2-wire, 4 mA ... 20 mA transmitter, HART interface
  • General corrosion, localized corrosion (pitting), and conductance monitoring via HART
  • Stern-Geary B value automatically updated for changes in the process

Mostrar más

Nota

Todos los documentos relacionados con los productos, como certificados, declaraciones de conformidad, etc., que se emitieron antes de la conversión con el nombre de Pepperl+Fuchs GmbH o Pepperl+Fuchs AG también se aplican a Pepperl+Fuchs SE.

EN
  • EN
  • DE

Datos técnicos de CMCM

Equipment architecture4 ... 20 mA output with HART protocol
Measured variableCorrosion update time:
- general, localized and conductance: 21 minutes
- general and conductance: 4 minutes
- local and conductance: 17 minutes
Output signal4 ... 20 mA with HART protocol
Electrical connection4 ... 20 mA with HART, 2-wire
Supply voltage2-wire HART (standard):
- current consumption 4 ... 22.5 mA
- min. terminal voltage 11 V (at 20 mA) without alarm / (at 22.5 mA) with alarm
- max. terminal voltage 30 V
Current consumption4 ... 22.5 mA
Maximum measured errorExcitation voltage < 0.05% of full span
Corrosion current measurement <0.2% of full span
ConfigurationThe adjustments and scaling can be done using a handheld terminal or the operating software.
General corrosion rate:
- range: max. 1000 mils/year, default 40 mils/year
- Zero/span adjustments available with HART
Localized corrosion (pitting) factor:
- default: 0.0 ... 1.0
- low pitting: 0.0 ... 0.3
- high pitting: 0.3 ... 1.0
Alarm configurationoutput signal when measurement is out of range:
- none
- high (22.5 mA), autoreset (default)
- high (22.5 mA), manual reset
Factory settingsB value (Stern Geary value): 25.6 mV
K value (corrosion constant): 11800 (2e- in reaction)
Response timedepends on configuration
- min. 4 min
- max. - 21 min
Installation conditionssee technical information (TI)
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Process conditions
Process temperaturestainless steel probe:
- direct mounting: max. 121 °C (250 °F)
- remote mounting: max. 260 °C (500 °F)
epoxy glass probe: max. 65 °C (149 °F)
Process pressure (static pressure)stainless steel probe max:
- adjustable/retractable: 102 bar (1500 psi)
- fixed: 206 bar (3000 psi)
- retrievable: 248 bar (3600 psi)
epoxy glass probe: max 7 bar
Flowmax. 6.1 m/s (20 fps)
Degree of protectionIP66, NEMA 4X
Dimensionssee section dimensions
Massapprox. 500 g , transmitter housing
Materialhousing: aluminum
process connections: stainless steel 1.4401/316L or Nylon
probes: stainless steel 1.4401/316L Hastelloy C or epoxy glass, fill material epoxy
end cap seal: glass or epoxy
electrode material: see section references to type code, table 1
o-ring: Viton (standard) or Kalrez (on request)
Explosion-hazardous areaLCIE 05 ATEX 6097X , for additional certificates see www.pepperl-fuchs.com
CSA approvalcCSAus certified for USA and Canada; Certificate no. 1563164
IS: Cl. I, II, III; Div. 1, 2; Groups A-G
EX: Cl. I; Div. 1, 2; Groups A-D
NI: Cl. I, II, III; Div. 2; Groups A-G
Type of protectionEx-Hexagon II 1G EEx ia IIC T4

Páginas relacionadas