6100-MP-LPP-* Pressure Sensor

Pressure sensor for 6100 series purge and pressurization system

Principaux avantages en un coup d'œil

  • Universal mounting in any orientation
  • Measures internal pressures from 0 to 25 mbar
  • 1 1/2 inch NPT process connection
  • Intrinsically safe when connected to 6100 control unit
Product Compliance: Europe – CE
Approval symbol
Product Compliance: United Kingdom – UKCA
Remarque

Tous les documents relatifs aux produits, tels que les certificats, les déclarations de conformité, etc., qui ont été émis avant la conversion sous le nom de Pepperl+Fuchs GmbH ou Pepperl+Fuchs AG, s'appliquent également à Pepperl+Fuchs SE.

EN
  • EN
  • DE
  • PT

Données techniques relatives à 6100-MP-LPP-*

Series6100 Series
SystemEx pxb Purge
Hazardous environmentgas
Connection
PowerIntrinsically safe connection to the 6100 control unit
SignalBus connection to 6100 control unit
ConnectionM12 connector, 4-pin, max length 30 m
LED indicationpower: green
Maximum pressure0 ... 25 mbar (0 ... 10 in wc) pressure range
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
RoHS
Directive 2011/65/EU (RoHS)EN IEC 63000:2018
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-30 ... 80 °C (-22 ... 176 °F)
Relative humidity5 ... 95 %, non-condensing
Vibration resistance10 ... 100 Hz , 1 g, all axes
Impact resistance30 g, 11 ms, all axes
Material5052 anodized aluminum, 6061T6 anodized aluminum
Installation- any orientation to enclosure
- not gravity dependent
Massapprox. 0.5 kg (1.1 lb)
Dimensions57.2 mm x 81.1 mm x 82.6 mm (2.3" x 3.2" x 3.3")
Height146 mm
Width127.5 mm
Depth82.5 mm
Mounting1 1/2" NPT knockout (50.8 mm (2") hole)
with sealing washer and nut
CertificateCML 19 ATEX 1425X
MarkingEx-Hexagon II 2 G Ex ib [pxb Gb] IIC T4 Gb
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018
EN 60079-2:2014
EN 60079-11:2012
IECEx approvalIECEx CML 19.0156X
Ex ib [pxb Gb] IIC T4 Gb
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Supplemental Standards : EN 61010-1:2010
Notes générales