Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Ladda ned datablad som PDF::
Utdrag ur datablad: Tekniska data för
ML6-8-H-120-IR/59/65a/115/136
Product Description |
Triangulation sensor with background suppression for standard applications, miniature design, 120 mm adjustable detection range, light/dark on, infrared light, two push-pull outputs, fixed cable |
General specifications |
Detection range | 15 ... 120 mm |
Detection range min. | 10 ... 30 mm |
Detection range max. | 18 ... 120 mm |
Adjustment range | 30 ... 120 mm |
Reference target | standard white, 100 mm x 100 mm |
Light source | IRED |
Light type | modulated infrared light , 880 nm |
Black-white difference (6 %/90 %) | < 10 % |
Diameter of the light spot | approx. 5 mm at detection range 120 mm |
Ambient light limit | |
| Continuous light | 40000 Lux |
| Modulated light | 5000 Lux |
Functional safety related parameters |
MTTFd | 1940 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green, statically lit Power on , Undervoltage indicator: Green LED, pulsing (approx. 0.8 Hz) , short-circuit : LED green flashing (approx. 4 Hz) |
Function indicator | LED yellow: lights when object is detected |
Control elements | Sensing range adjuster |
Electrical specifications |
Operating voltage | 10 ... 30 V DC , class 2 |
Ripple | max. 10 % |
No-load supply current | < 25 mA |
Output |
Switching type | light/dark on, programmable |
Signal output | 2 push-pull (4 in 1) outputs, complementary, short-circuit proof, reverse polarity protected |
Switching voltage | max. 30 V DC |
Switching current | max. 100 mA |
Voltage drop | ≤ 2.5 V DC |
Switching frequency | 1000 Hz |
Response time | 500 µs |
Compliance with standards and directives |
Standard conformity | |
| Product standard | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
| Shock and impact resistance | IEC / EN 60068. half-sine, 40 g in each X, Y and Z directions |
| Vibration resistance | IEC / EN 60068-2-6. Sinus. 10 -150 Hz, 5 g in each X, Y and Z directions |
Approvals and certificates |
UL approval | cULus Listed |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Storage temperature | -40 ... 75 °C (-40 ... 167 °F) |
Mechanical specifications |
Degree of protection | IP67 / IP69K |
Connection | 2 m fixed cable |
Material | |
| Housing | ABS |
| Optical face | PMMA |
| Cable | PUR |
Mass | approx. 50 g |
Dimensions | |
| Height | 31.4 mm |
| Width | 13.9 mm |
| Depth | 18 mm |
Classifications
System | Classcode |
ECLASS 13.0 | 27270903 |
ECLASS 12.0 | 27270903 |
ECLASS 11.0 | 27270904 |
ECLASS 10.0.1 | 27270904 |
ECLASS 9.0 | 27270904 |
ECLASS 8.0 | 27270904 |
ECLASS 5.1 | 27270904 |
ETIM 9.0 | EC002719 |
ETIM 8.0 | EC002719 |
ETIM 7.0 | EC002719 |
ETIM 6.0 | EC002719 |
ETIM 5.0 | EC002719 |
UNSPSC 12.1 | 39121528 |
Details:
ML6-8-H-120-IR/59/65a/115/136
Product Documentation:
ML6-8-H-120-IR/59/65a/115/136
Design / Simulation:
ML6-8-H-120-IR/59/65a/115/136
Approvals:
ML6-8-H-120-IR/59/65a/115/136
Associated Products:
ML6-8-H-120-IR/59/65a/115/136
Accessories |
|
|
|
Mounting Clampfa |
|
|
|
|
Mounting bracket fa |
|
|
|
|
Mounting bracket fa |
|
|
|
|
Mounting bracket fa |
|