Fieldbus power supply, module for fieldbus power hub, Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk
Advanced diagnostic module, plug-in module for the fieldbus power hub, Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada
Barrera aislada de 1 canal, Alimentación de 24 V CC (carril de alimentación), Transmisores de 2 y tres hilos de entrada y fuentes de corriente de 2 hilos, Salida 0/4 mA ... 20 mA, 2 salidas de contacto de relé, Retardo ajustable con/sin tensión, Alarma máx./mín. programable, Función de linealización (máx. 20 puntos), Supervisión de fallos de conducción, Hasta SIL 2 según IEC/EN 61508 / IEC/EN 61511, Anchura de la carcasa: 40 mm, Cantidad de canales: 1 canal, Relés de valores límite
Interfaz para carril de alimentación, Se utiliza para configuración redundante, Corriente de alimentación ≤ 4 A, Fusible reemplazable, Salida de contacto de relé, reversible, Indicación de estado LED
Barrera aislada de 2 canales, Alimentación de 24 V CC (carril de alimentación), Salida de corriente hasta 650 Ω de carga, HART-IP y posicionador de válvula, Supervisión de fallos de conducción, Precisión 0,1 %, Hasta SIL 2 (SC 3) conforme a IEC/EN 61508, Anchura de la carcasa: 20 mm, Cantidad de canales: 2 canales, Dirección de la transmisión: al campo, Comunicación HART, Conectores hembra de prueba, Nivel de integridad de seguridad (SIL): SIL 2, Capacidad sistemática (SC): SC 3
Barrera aislada de 2 canales, Alimentación de 24 V CC (carril de alimentación), Entradas de contacto o NAMUR, 2 salidas de transistor pasivas, Dirección de la acción reversible, Supervisión de fallos de conducción, Hasta SIL 2 (SC 3) conforme a IEC/EN 61508, Anchura de la carcasa: 20 mm, Cantidad de canales: 2 canales, Nivel de integridad de seguridad (SIL): SIL 2, Capacidad sistemática (SC): SC 3, Tensión de medición: 19 ... 30 V CC, Dispositivo en campo: Sensor NAMUR
Barrera aislada de 2 canales, Alimentación de 24 V CC (carril de alimentación), Entrada para transmisores SMART de 2 hilos y 3 hilos y fuentes de corriente SMART de 2 hilos, Salida 4 mA ... 20 mA, disipador de corriente/fuente de corriente, Terminales con puntos de prueba, Hasta SIL 2 (SC 3) conforme a IEC/EN 61508, Anchura de la carcasa: 20 mm, Cantidad de canales: 2 canales, Comunicación HART, Conectores hembra de prueba, Nivel de integridad de seguridad (SIL): SIL 2, Capacidad sistemática (SC): SC 3
Barrera aislada de 1 canal, Alimentación de 24 V CC (carril de alimentación), Entrada para contactos secos o sensores NAMUR, Frecuencia de entrada 1 mHz ... 5 kHz, Salida de corriente de 0/4 mA ... 20 mA, Contacto de relé y salida de transistor, Puenteado de arranque, Supervisión de fallos de conducción, Hasta SIL 2 según IEC/EN 61508 / IEC/EN 61511, Anchura de la carcasa: 40 mm, Cantidad de canales: 1 canal, Relés de valores límite, Puenteado de arranque
Barrera aislada de 2 canales, Alimentación de 24 V CC (carril de alimentación), Entrada de tensión, potenciómetro, RTD o termopar, Se puede utilizar como divisor de señal (1 entrada y 2 salidas), Salida de corriente de 0/4 mA ... 20 mA, Modo disipador o fuente, Configurable mediante PACTware, Detección de fallo de línea (LDF) y daños en el sensor, Hasta SIL 2 según IEC/EN 61508 / IEC/EN 61511, Anchura de la carcasa: 20 mm, Cantidad de canales: 2 canales
Additional Management tool for VisuNet Remote Monitors and Box Thin Clients, User-friendly, centralized management tool, Remotely configure (e.g., IP address) Remote Monitors, Create and edit remote profiles (e.g. a RDP connection profile) on a Remote Monitor, Copy profiles from one Remote Monitor to another Remote Monitor, Monitor the operators screen and support them remotely via "session shadowing"
Thin Client Firmware for VisuNet Remote Monitors, Box Thin Clients and Tablet Thin Clients (mobile), Innovative firmware to support easy integration and management of remote monitors and thin clients, Supports installation of third-party applications, such as Citrix Receiver and Java Runtime, Based on Microsoft® Windows 10 IoT Enterprise LTSC 2019, Microsoft Universal Write Filter, firewall, USB lock-down, and virus scanner support for maximum system security, Auto connect to host systems after RM startup
Thin Client Firmware for VisuNet Remote Monitors, Box Thin Clients and Tablet Thin Clients (mobile), Innovative firmware to support easy integration and management of remote monitors and thin clients, Supports installation of third-party applications, like Citrix Receiver and Embedded Webbrowsers, Microsoft Unified Write Filter, firewall, USB lock-down, and virus scanner support for maximum system security, Based on Microsoft® Windows 11 IoT Enterprise LTSC 2024
VisuNet FLX Edge Workstation, Class I, Division 1 solution with integrated 6000 Series Type X Purge & Pressurization system, Class I, II, Division 2 and General Purpose solution without Purge & Pressurization system, Fully modular design using VisuNet FLX HMI and EXTA4 keyboard options support field maintainability, Available as Windows® PC or Thin Client with RM Shell, ThinManager Ready, or IGEL OS, Watershed housing allows for proper drainage in outdoor or washdown environments
Type Y & Z pressurization system for Class I and II areas
Type Y & Z pressurization system for Class II areas
Type Y & Z pressurization system for Class I areas
Type Z purge and pressurization system for Class I and Class II areas
Type Z purge and pressurization system for Class I areas
Environmental purge for nonhazardous dusty/dirty areas
Bebco EPS 5500 series Type Z & Ex pzc purge and pressurization control unit
The 5500-ACC-BKT provides easy installation of the 5500-01 external control unit to an enclosure, with or without 5500-MAN manifold. Mounting hardware is included; control unit and manifold are not included.
6000 Series Type X and Ex pxb purge and pressurization system control unit
6500 series Ex pxb and Ex pyb purge and pressurization system
You must purchase an EPV-7500-* vent with the control unit.
The 7500-ACC-BKT bracket provides easy installation of the 7500-01 control unit to an enclosure, with or without 5500-MAN manifold (not included).
7500 series type Z & Ex pzc purge and pressurization controller for panel and external mounting
You must purchase an EPV-7500-* vent with this control unit.
FieldConnex®, Ethernet-APL rail field switch with 8, 16, 24 intrinsically safe Ex ia spur ports and screw/spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, Installation in Zone 2, IECEx approval, International, Europe
FieldConnex®, Ethernet-APL rail field switch with 8, 16, 24 intrinsically safe Ex ic spur ports and screw/spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, IECEx approval
Multivuelta hasta 30 bits, Certificado ATEX, Certificación IECEx, Resistente a la presión encapsulado, Tapa de conexión extraíble, Tipo de carcasa: 78 mm, Versión de eje: Eje macizo, Interfaz: SSI, Aplicación: Protección Ex, Modo de detección: Exploración fotoeléctrico, Tipo de Interfaz: SSI, Modo de entrada: Selección del sentido de contaje (A/D)
Hasta 16 bits, monovuelta, Certificado ATEX, Certificación IECEx, Resistente a la presión encapsulado, Tapa de conexión extraíble, Tipo de carcasa: 78 mm, Versión de eje: Eje macizo, Interfaz: SSI, Aplicación: Protección Ex, Modo de detección: Exploración fotoeléctrico, Tipo de Interfaz: SSI, Modo de entrada: Selección del sentido de contaje (A/D)
Industrial Box PC, 7th generation Intel Celeron and i5 embedded processor generation, Supports high performance M.2 NVMe storage, Robust, fanless industrial design with -20 … +55 °C, Installation flexibility: stand-alone PC, Panel PC, system with enclosure, Integrated intrinsically safe USB ports for keyboard connections
Función de conmutación: Normalmente abierto (NA), Tipo de salida: NAMUR, Instalación: enrasado, Tipo de salida: 2-hilos, Molde de rosca: M30, Tipo: Cilíndrico, rosca, Serie: cilíndrico, otros, Tipo de tensión: CC, Nivel de protección del equipo Ga: BVS 13 ATEX E 074 X, Nivel de protección del equipo Da: BVS 13 ATEX E 074 X, Tipo de conexión: Cable, Material de la carcasa: Acero inoxidable 1.4305 / AISI 303, Grado de protección: IP67
Función de conmutación: Normalmente abierto (NA), Tipo de salida: NAMUR, Instalación: enrasado, Tipo de salida: 2-hilos, Molde de rosca: M30, Tipo: Cilíndrico, rosca, Serie: cilíndrico, otros, Tipo de tensión: CC, Nivel de protección del equipo Ga: BVS 13 ATEX E 074 X, Nivel de protección del equipo Da: BVS 13 ATEX E 074 X, Tipo de conexión: Conector macho, Material de la carcasa: Acero inoxidable 1.4305 / AISI 303, Grado de protección: IP67, Rosca: M12 x 1
Tightening tool for CFP locknut spanners, Polyamide, Function: Locknut spanner, operator
SS316L shroud, padlockable, Ex e certified, Stainless Steel, Component for appropriately certified Ex e enclosures, Function: Emergency stop padlockable shroud, cover-mounted
Función de conmutación: Normalmente abierto (NA), Tipo de salida: NAMUR, Instalación: no enrasado, Tipo de salida: 2-hilos, Molde de rosca: M12, Tipo: Cilíndrico, rosca, Serie: cilíndrico, otros, Tipo de tensión: CC, Nivel de protección del equipo Ga: IECEx TUN 20.0014X, Nivel de protección del equipo Gb: IECEx TUN 20.0014X, Nivel de protección del equipo Da: IECEx TUN 20.0014X, Nivel de protección del equipo Ga: TÜV 03 ATEX 2003 X, Nivel de protección del equipo Gb: TÜV 03 ATEX 2003 X
Función de conmutación: Normalmente abierto (NA), Tipo de salida: NAMUR, Instalación: no enrasado, Tipo de salida: 2-hilos, Molde de rosca: M18, Tipo: Cilíndrico, rosca, Serie: cilíndrico, otros, Tipo de tensión: CC, Nivel de protección del equipo Ga: IECEx TUN 20.0014X, Nivel de protección del equipo Gb: IECEx TUN 20.0014X, Nivel de protección del equipo Da: IECEx TUN 20.0014X, Nivel de protección del equipo Ga: TÜV 03 ATEX 2003 X, Nivel de protección del equipo Gb: TÜV 03 ATEX 2003 X