General specifications | ||
---|---|---|
Signal type | Analog input | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Supply | ||
Connection | SL1: 1a(-), 1b(-); 2a(+), 2b(+) | |
Rated voltage | 20 ... 30 V DC bus powered via Termination Board | |
Ripple | within the supply tolerance | |
Power dissipation/power consumption | ≤ 0.98 W / 0.98 W | |
Input | ||
Connection side | field side | |
Connection | SL2: 5a(+), 1a(+), 1b(-), 5b(-) | |
RTD | type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995) type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94) type Cu10, Cu50, Cu100 (P50353-92) type Ni100 (DIN 43760) |
|
Measuring current | approx. 200 µA with RTD | |
Types of measuring | 2-, 3-, 4-wire connection | |
Lead resistance | max. 50 Ω per line | |
Measurement loop monitoring | sensor breakage, sensor short-circuit | |
Thermocouples | type B, E, J, K, N, R, S, T (IEC 584-1: 1995) type L (DIN 43710: 1985) type TXK, TXKH, TXA (P8.585-2001) |
|
Cold junction compensation | external and internal | |
Measurement loop monitoring | sensor breakage | |
Potentiometer | 0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection) | |
Types of measuring | 3-wire connection | |
Voltage | selectable within the range -100 ... 100 mV | |
Input resistance | ≥ 1 MΩ (-100 ... 100 mV) | |
Output | ||
Connection side | control side | |
Connection | SL1: 8a(+), 7a(-) | |
Output | Analog current output | |
Current range | 0 ... 20 mA or 4 ... 20 mA | |
Fault signal | downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43) | |
Source | load 0 ... 550 Ω open-circuit voltage ≤ 18 V |
|
Sink | Voltage across terminals 5 ... 30 V. If the current is supplied from a source > 25 V, series resistance of ≥ (V - 25)/0.0215 Ω is needed, where V is the source voltage. The maximum value of the resistance is (V - 5)/0.0215 Ω. |
|
Fault indication output | ||
Connection | SL1: 6b | |
Output type | open collector transistor (internal fault bus) | |
Transfer characteristics | ||
Reaction time | worst case value (sensor breakage and/or sensor short circuit detection enabled) mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s |
|
Indicators/settings | ||
Display elements | LEDs | |
Control elements | DIP-switch | |
Configuration | via DIP switches via PACTware |
|
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2011 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Mass | approx. 100 g | |
Dimensions | 12.5 x 128 x 106 mm (0.5 x 5.1 x 4.2 inch) | |
Mounting | on Termination Board | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | BASEEFA 14 ATEX 0129 X | |
Marking | ![]() ![]() ![]() |
|
Certificate | BASEEFA 14 ATEX 0130 X | |
Marking | ![]() |
|
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
UL approval | ||
Control drawing | 116-0391 (cULus) | |
IECEx approval | IECEx BAS 14.0071X IECEx BAS 16.0003X |
|
Approved for | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Ex nA IIC T4 Gc |
CAD | Tipo de archivo | Tamaño | |
---|---|---|---|
Dimension drawing 2-D (DXF) / Abmessungszeichnung 2-D (DXF) | ZIP | 16364 KB |
Statements of compliance | Número de Certificado | Tipo de archivo | Tamaño |
---|---|---|---|
EU-Declaration of conformity / EU-Konformitätserklärung | DOC-0748E | 147 KB | |
Certificates | |||
Baseefa IECEx Certificate of Conformity | IECEx BAS 14.0071X | LINK | --- |
Baseefa Type n Zone 2 IECEx Certificate of Conformity | IECEx BAS 16.0003X | LINK | --- |
Belarus Pattern Approval | Nr. 11708 | 8943 KB | |
Brasil TUV Rheinland Brazil | TÜV 16.0819 | 1292 KB | |
Canada FM | FM 17 CA 0057X | 303 KB | |
Canada UL cUL | E106378 cUL (QUZW8) | LINK | --- |
Canada UL cUL | E106378 cUL (QVAJ8) | LINK | --- |
China NEPSI | GYJ 18.1357X | 1950 KB | |
EAC NANIO "CCVE" EAC TP TC 012/2011 | TC RU C-DE.AA87.B.00210 | 1396 KB | |
Europe Baseefa ATEX Category (1) D ATEX Category (M1) ATEX Category (1) G | Baseefa 14 ATEX 0129X | 656 KB | |
Europe Baseefa ATEX Category 3 G | Baseefa 14 ATEX 0130X | 511 KB | |
India PESO (India) CCOE | A/P/HQ/KA/104/5619 (P431258) | 1019 KB | |
Korea KOSHA | 15-AV4BO-0593 | 609 KB | |
USA Canada UL Hazardous Location Certificate of Compliance cULus UL E106378 | CoC 20140403 - E106378 RepRef 20140331 | 427 KB | |
USA FM | FM 17 US 0111X | 142 KB | |
USA UL | E106378 UL (QVAJ2) | LINK | --- |
USA UL | E106378 UL (QUZW2) | LINK | --- |
Control drawings | |||
Control Drawing FM / Control Drawing FM | 88 KB | ||
Control Drawing UL / Control Drawing UL | 59 KB |
Device type managers | Liberar Info | Tipo de archivo | Tamaño |
---|---|---|---|
DTM Collection Interface Technology 2 / DTM Collection Interface Technology 2 | 1.4.110.71 | ZIP | 33316 KB |
Software Tools | |||
PACTware 4.1 SP5 / PACTware 4.1 SP5 | 4.1.0.52 | ZIP | 50675 KB |
PACTware 5.0 / PACTware 5.0 | 5.0.4.20 | ZIP | 50037 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|