Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Descargue la hoja de datos completa en PDF:
General specifications | ||
---|---|---|
Signal type | Digital Input | |
Supply | ||
Connection | d14+, d16+, z14- | |
Rated voltage | 20 ... 30 V DC | |
Ripple | ≤ 10 % | |
Rated current | ≤ 150 mA | |
Input | ||
Connection | channel 1: d2+, z2- channel 2: d6+, z6- |
|
Open circuit voltage/short-circuit current | approx. 8.4 V DC / approx. 11.7 mA | |
Switching point | ||
Relay de-energized | I < 2.1 mA and I > 5.8 mA , output switched off | |
Relay energized | 2.8 mA < I < 4.9 mA , output switched on | |
Response delay | ≤ 1 ms | |
Output | ||
Output I and III | active voltage output, short-circuit proof | |
Connection | channel 1: d32+, z30- channel 2: d26+, z24 |
|
Rated voltage | 24 V DC (> 16 V DC) | |
Rated current | > 15 mA (current limited) | |
Output II and IV | fault signal; passive electronic output | |
Connection | channel 1: d20+, z20- channel 2: d18+, z18- |
|
Rated voltage | 10 ... 30 V DC | |
Rated current | 15 mA (current limited) | |
Voltage drop | approx. 2.5 V | |
Off-state current | ≤ 10 µA | |
Transfer characteristics | ||
Switching frequency | 50 Hz | |
Galvanic isolation | ||
Output/power supply | functional insulation acc. to EN 50178, rated insulation voltage 50 Veff | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | The device has been used for the same applications for several years. It therefore features an appropriate electromagnetic field immunity. The device must not be used in new plants. | |
Conformity | ||
Insulation coordination | EN 50178 | |
Degree of protection | IEC 60529 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | 32-pin plug connector acc. to DIN 41612 , series 2 , type F , z and d provided | |
Mass | approx. 190 g | |
Dimensions | 20 x 128 x 193 mm (0.8 x 5 x 7.6 inch) | |
Height | 128 mm | |
Width | 20 mm | |
Length | 193 mm | |
Construction type | Eurocard 100 x 160 mm (3.9 x 6.3 inch) acc. to DIN 41494, front panel 4TE, mountable in 19 inch rack | |
Coding | a1/c3 | |
Data for application in connection with hazardous areas | ||
EU-type examination certificate | PTB 00 ATEX 2209 , for additional certificates see www.pepperl-fuchs.com | |
Marking | II (1)GD [EEx ia] IIC | |
Input | EEx ia IIC | |
Voltage | 9.6 V | |
Current | 17 mA | |
Power | 41 mW (linear characteristic) | |
Supply | ||
Maximum safe voltage | 40 V (Attention! The rated voltage can be lower.) | |
Output | ||
Maximum safe voltage | 60 V (Attention! The rated voltage can be lower.) | |
Fault indication output | ||
Maximum safe voltage | 60 V (Attention! The rated voltage can be lower.) | |
Galvanic isolation | ||
Input/Output | safe galvanic isolation acc. to EN 50020, voltage peak value 375 V | |
Input/power supply | safe galvanic isolation acc. to EN 50020, voltage peak value 375 V | |
Directive conformity | ||
Directive 94/9/EC | EN 50014:1997, EN 50020:1994 | |
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27210121 |
ECLASS 12.0 | 27210121 |
ECLASS 11.0 | 27210121 |
ECLASS 10.0.1 | 27210121 |
ECLASS 9.0 | 27210121 |
ECLASS 8.0 | 27210121 |
ECLASS 5.1 | 27210121 |
ETIM 9.0 | EC001485 |
ETIM 8.0 | EC001485 |
ETIM 7.0 | EC001485 |
ETIM 6.0 | EC001485 |
ETIM 5.0 | EC001485 |
UNSPSC 12.1 | 32101514 |
Manuals | Idioma | Tipo de archivo | Tamaño |
---|---|---|---|
Brief Instructions - E-system | ENG | 320 KB |