Switch Amplifier ED2-SR-Ex8

ED2-SR-Ex8
  • 8-channel isolated barrier
  • 24 V DC supply
  • Dry contact or NAMUR inputs
  • Relay output
  • Fault indication output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Configurable via PC

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Extracto de la hoja de datos: Información técnica del  ED2-SR-Ex8

General specifications
Signal typeDigital Input
Supply
Connectiond14+, z14-
Rated voltage20 ... 30 V DC
Ripple≤ 10 %
Power consumptionapprox. 4 W
Input
Connectionchannel 1: d2-, b2+
channel 2: d4-, b2+
channel 3: d6-, b4+
channel 4: d8-, b4+
channel 5: z2-, b6+
channel 6: z4-, b6+
channel 7: z6-, b8+
channel 8: z8-, b8+
Rated valuesacc. to EN 60947-5-6 (NAMUR), see manual for electrical data
Open circuit voltage/short-circuit currentapprox. 7.5 V DC / approx. 7.5 mA
Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detectionbreakage I ≤ 0.15 mA , short-circuit I > 6 mA
Pulse length/pulse interval≥ 1 ms / ≥ 1 ms
Output
Connectionchannel 1: d22, d24
channel 2: d26, d28
channel 3: d30, d32
channel 4: b22, b24
channel 5: b26, b28
channel 6: b30, b32
channel 7: z22, z24
channel 8: z26, z28
Outputsignal ; relay
Contact loading60 V AC/1 A/60 VA; 60 V DC/1 A resistive load/24 W
Energized/De-energized delay5 ms / 5 ms
Mechanical life2 x 107 switching cycles
Fault indication output
Connectionz30, z32
Outputfault signal ; relay
Contact loading60 V AC/1 A/60 VA; 60 V DC/1 A resistive load/24 W
Energized/De-energized delay5 ms / 5 ms
Mechanical life2 x 107 switching cycles
Transfer characteristics
Switching frequency< 10 Hz
Galvanic isolation
Output/power supplybasic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff
Output/Outputbasic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECThe device has been used for the same applications for several years. It therefore features an appropriate electromagnetic field immunity. The device must not be used in new plants.
Low voltage
Directive 2006/95/ECEN 50178:1997
Conformity
Insulation coordinationEN 50178
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Connection48-pin plug connector acc. to DIN 41612 , series 2 , type F , z, b and d provided
Massapprox. 175 g
Dimensions20 x 128 x 193 mm (0.8 x 5 x 7.6 inch)
Height128 mm
Width20 mm
Length193 mm
Construction typeEurocard 100 x 160 mm (3.9 x 6.3 inch) acc. to DIN 41494, front panel 4TE, mountable in 19 inch rack
Codinga1/a7
Data for application in connection with hazardous areas
EU-type examination certificatePTB 00 ATEX 2207 , for additional certificates see www.pepperl-fuchs.com
MarkingEx-Hexagon II (1)GD [EEx ia] IIC
InputEEx ia IIC
Voltage11.8 V
Current14.6 mA
Power43 mW (linear characteristic)
Supply
Maximum safe voltage40 V (Attention! The rated voltage can be lower.)
Output
Maximum safe voltage253 V (Attention! The rated voltage can be lower.)
Interface
Maximum safe voltage60 V (Attention! The rated voltage can be lower.)
Galvanic isolation
Input/Outputsafe galvanic isolation acc. to EN 50020, voltage peak value 375 V
Input/power supplysafe galvanic isolation acc. to EN 50020, voltage peak value 375 V
Directive conformity
Directive 94/9/ECEN 50014:1997, EN 50020:1994
General information
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Accessories
Designation- adapter with RS 232 interface
- SOSA configuration software

Classifications

SystemClasscode
ECLASS 13.027210121
ECLASS 12.027210121
ECLASS 11.027210121
ECLASS 10.0.127210121
ECLASS 9.027210121
ECLASS 8.027210121
ECLASS 5.127210121
ETIM 9.0EC001485
ETIM 8.0EC001485
ETIM 7.0EC001485
ETIM 6.0EC001485
ETIM 5.0EC001485
UNSPSC 12.132101514

Details: ED2-SR-Ex8

Datasheet: ED2-SR-Ex8

DatasheetTipo de archivoTamaño
Datasheet ED2-SR-Ex8PDF236 KB
Datenblatt ED2-SR-Ex8PDF239 KB

Documents: ED2-SR-Ex8

ManualsTipo de archivoTamaño
Brief Instructions - E-systemPDF320 KB
Kurzanleitung - E-SystemPDF565 KB