Línea de servicio de Sensores Industriales
Atención al cliente para protección contra explosiones
No disponible para compra
No disponible para compra

Solenoid Valve FU6-PV32*-Ex

FU6-PV32*-Ex
  • Minimal purging gas consumption
  • High level of operating safety
  • Low flow noise
  • Defined overpressure during purging

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Descargue la hoja de datos completa en PDF:


Extracto de la hoja de datos: Información técnica del  FU6-PV32*-Ex

Descripción del producto
230 V AC
Supply
Rated voltage230 V AC
Operating conditions
Process conditions
Process pressure (static pressure)F**-PV321-Ex: 0 ... 7 bar
F**-PV322-Ex: 0 ... 3.5 bar
Mechanical specifications
Degree of protectionIP65
Connectioncable, 3 m length
Dimensions56 x 80 x 105 mm (2.2 x 3.1 x 4.1 inch)
Height80 mm
Width56 mm
Length105 mm
Data for application in connection with hazardous areas
EU-type examination certificatePTB 00 ATEX 2202 X (Bürkert)
MarkingEx-Hexagon II 2G EEx m II T4 or T6
Ex-Hexagon II 2G EEx em II T4 or T6
Directive conformity
Directive 94/9/ECEN 50014, EN 50019, EN 50028
General information
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027180591
ECLASS 12.027180591
ECLASS 11.027180591
ECLASS 10.0.127291390
ECLASS 9.027291390
ECLASS 8.027291390
ECLASS 5.140050501
ETIM 9.0EC000243
ETIM 8.0EC000243
ETIM 7.0EC000243
ETIM 6.0EC000243
ETIM 5.0EC000243
UNSPSC 12.139121303

Details: FU6-PV32*-Ex

Product Documentation: FU6-PV32*-Ex

Seleccionar idioma:
Safety and Security DocumentationIdiomaTipo de archivoTamaño
Instruction Manual PCU300AENGPDF159 KB
Manuals
Manual PCU300AENGPDF394 KB