Línea de servicio de Sensores Industriales
Atención al cliente para protección contra explosiones
No disponible para compra
No disponible para compra

ControlNet gateway, baseline KSD2-GW-CN.B

KSD2-GW-CN.B
  • Connects the Remote Process Interface to the control system/PLC/PC via ControlNet
  • Couples the internal CAN bus to the external ControlNet
  • Device installation in Zone 2
  • For the connection of max. 16 RPI devices
  • Master function for the internal CAN bus
  • External bus: ControlNet
  • External baud rate 5 MBd
  • Separate RS 232 connection on front side for system configuration, also directed to terminals for creating a subordinate monitoring system
  • 24 V DC nominal supply voltage
  • External bus is always media-redundant
  • Redundancy of the gateways and external buses not possible
  • EMC acc. to NAMUR NE 21

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Descargue la hoja de datos completa en PDF:


Extracto de la hoja de datos: Información técnica del  KSD2-GW-CN.B

Supply
ConnectionPower Rail
Rated voltage20 ... 30 V DC
Ripple< 10 %
Power consumption3.6 W
Internal bus
ConnectionPower Rail
InterfaceCAN protocol via Power Rail bus
Cycle time1 device 25 ms
16 devices with discrete input 29 ms
16 devices with discrete output 33 ms
16 devices with analog input 31 ms
16 devices with analog output 35 ms
External bus
ConnectionBNC A, B; NAP
InterfaceControlNet
Service interface
Connectionterminals 22, 23, 24 and jack bush
InterfaceRS 232
Galvanic isolation
Internal/external busbasic insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff AC
Internal bus/power supplynot available
External bus/power supplybasic insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff AC
Service interface/internal busbasic insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff AC
Service interface/external busbasic insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff AC
Service interface/supplybasic insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff AC
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Massapprox. 520 g
Data for application in connection with hazardous areas
Statement of conformityTÜV 00 ATEX 1617 X (observe statement of conformity)
Group, category, type of protection, temperature classEx-Hexagon II 3G EEx nA II T4

Classifications

SystemClasscode
ECLASS 13.027210990
ECLASS 12.027210990
ECLASS 11.027210990
ECLASS 10.0.127210990
ECLASS 9.027210990
ECLASS 8.027210990
ECLASS 5.127210107
ETIM 9.0EC001485
ETIM 8.0EC001485
ETIM 7.0EC001485
ETIM 6.0EC001485
ETIM 5.0EC001598
UNSPSC 12.132101514

Details: KSD2-GW-CN.B

Product Documentation: KSD2-GW-CN.B

Seleccionar idioma:
Safety and Security DocumentationIdiomaTipo de archivoTamaño
Operating instructions RPI-SystemENGPDF1459 KB
Manuals
ManualENGPDF8037 KB

Productos asociados: KSD2-GW-CN.B

Accessories
Device DTM, For Remote I/O systems, Function only with PACTware 2.4 (contained in DTM Collection)pa