Selecteer uw land
RLK28-55/31/116 Retroreflective Sensor
Retroreflective sensor with polarization filter
Belangrijkste voordelen in één oogopslag
- Universal series with highly versatile fields of use
- Resistant against noise: reliable operation under all conditions
- Version with red light
- Version with relay output
Voorkeurstype











Opmerking
Alle productgerelateerde documenten, zoals certificaten, conformiteitsverklaringen, enzovoort, die vóór de omzetting onder de naam Pepperl+Fuchs GmbH of Pepperl+Fuchs AG zijn afgegeven, zijn ook van toepassing op Pepperl+Fuchs SE.
EN
- EN
- DE
- ES
- FR
- IT
- ZH
Technische gegevens van RLK28-55/31/116
| Effective detection range | 0 ... 17 m | |
| Reflector distance | 0.05 ... 17 m | |
| Threshold detection range | 21 m | |
| Reference target | H85-2 reflector | |
| Light source | LED | |
| Light type | modulated visible red light | |
| Polarization filter | yes | |
| Diameter of the light spot | approx. 290 mm at a distance of 17 m | |
| Opening angle | emitter 1.2° receiver 2° | |
| Ambient light limit | 80000 Lux |
| MTTFd | 600 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % |
| Operation indicator | LED green | |
| Function indicator | 2 LEDs yellow, light up when light beam is free, flash when falling short of the operating reserve, are off when light beam is interrupted | |
| Control elements | sensitivity adjustment (Adjustment to < 25% of the effective operating range) , Light-on/dark-on changeover switch |
| Operating voltage | UB | 12 ... 240 V AC/DC |
| Power consumption | P0 | ≤ 3.5 VA |
| Switching type | light/dark on switchable | |
| Signal output | Relay, 1 alternator | |
| Switching voltage | max. 250 V AC/DC | |
| Switching current | max. 2 A | |
| Switching power | DC: max. 50 W AC: max. 500 VA | |
| Switching frequency | f | 25 Hz |
| Response time | 20 ms |
| Product standard | EN 60947-5-2 |
| Protection class | II, rated insulation voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Output circuit insulated from control circuit in accordance with IEC 61140. Caution! The protection class 2 is only valid when the terminal compartment is closed. | |
| UL approval | E87056 , cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508. | |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
| Storage temperature | -40 ... 60 °C (-40 ... 140 °F) |
| Degree of protection | IP64 | ||||||||||
| Connection | terminal compartment with 8 spring-loaded terminals for wire cross section 0.5 ... 1.5 mm2 , Insulation stripping 7.5 ... 8.5 mm , M16 x 1.5 cable gland | ||||||||||
| Material | |||||||||||
| |||||||||||
| Mass | 112 g | ||||||||||
| Dimensions | |||||||||||
| |||||||||||
Gerelateerde pagina's
Bent u op zoek naar meer informatie? U kunt meer informatie vinden op onze gerelateerde pagina's.