Selecione seu país
PMI14V-F112-2EPE2-IO-Y70104219 Inductive Position Measurement
Principais benefícios
- Parameterization and diagnosis via IO-Link
- 3 configurable switching frames
- Measuring range 0 ... 14 mm
- Shielded line 2 m









Nota
Todos os documentos relacionados ao produto, como certificados, declarações de conformidade etc., que foram emitidos antes da conversão sob o nome Pepperl+Fuchs GmbH ou Pepperl+Fuchs AG, também se aplicam à Pepperl+Fuchs SE.
EN
- EN
- DE
- ES
- FR
Dados técnicos de PMI14V-F112-2EPE2-IO-Y70104219
| Installation | flush | |
| Object distance | max. 2.5 mm | |
| Measuring range | 0 ... 14 mm |
| Operating voltage | UB | 10 ... 30 V |
| Reverse polarity protection | reverse polarity protected | |
| Linearity error | ± 0.3 mm | |
| Repeat accuracy | R | ± 0.05 mm |
| Resolution | 33 µm | |
| Temperature drift | ± 0.5 mm | |
| No-load supply current | I0 | ≤ 20 mA |
| Operating voltage indicator | LED green |
| MTTFd | 490 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % |
| Interface type | IO-Link | |
| Mode | COM2 (38.4 kBit/s) | |
| Value range | 0000h ... 7000h |
| Output type | 2 Push-pull (4 in 1) outputs , 1 switch output PNP , short-circuit protected , reverse polarity protected , overvoltage protected , programmable | |
| Operating current | IL | ≤ 100 mA / Output |
| Switching hysteresis | 3-step, adjustable 0.2 m ... 0.8 mm | |
| Voltage drop | ≤ 3 V | |
| Short-circuit protection | pulsing |
| Standard conformity | |||||
| |||||
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Connection type | 2 m PUR cable , screened | ||||||||||
| Housing material | PA 66 | ||||||||||
| Degree of protection | IP67 | ||||||||||
| Material | |||||||||||
| |||||||||||
| Dimensions | |||||||||||
| |||||||||||
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5 mm. | ||||||||||
| Airtightness | solid: min. 0.5 bar (over the entire operating temperature) during 1 min: min. 3 bar (at room temperature) |