EIP/MOD Fieldbus module ICE2-8IOL-K45S-RJ45

ICE2-8IOL-K45S-RJ45
  • Web-based configuration of module and IO-Link devices
  • Integrated IODD storage for more than 100 IODDs
  • Downloadable module configuration
  • Screw terminal power connector
  • EtherNet/IP, Modbus/TCP and OPC UA support

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Descargue la hoja de datos completa en PDF:


Extracto de la hoja de datos: Información técnica del  ICE2-8IOL-K45S-RJ45

Descripción del producto
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, screw terminal
General specifications
UL File NumberE360395
Indicators/operating means
LED indicationsee manual
Electrical specifications
Rated operating voltage18 ... 30 V DC
Nominal voltage24 V DC
Nominal current3.7 A
Current consumptiontyp. 155 mA
Current loading capacityTotal current 3.2 A per module
Interface 1
Interface typeIndustrial Ethernet
Physical RJ45
ProtocolEtherNet/IP + Modbus TCP + OPC UA
Transfer rate10/100 Mbps
Inputs/Outputs
Number/Type8 x IO-Link Class A (X1 – X8) Configurable as: Max. 8 IO-Link and 8 digital inputs Max. 16 digital inputs Max. 8 digital inputs and 8 digital outputs
short-circuit protected
Sensor supplymax. 200 mA Per port Via L+ (pin 1)
Output rated operating currentmax. 200 mA Per port Via C/Q (pin 4)
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61000-6-2 , EN 61000-6-4
Standard conformity
Degree of protectionEN 60529
Fieldbus standardType 1 according to IEC 61131-2, EN 61131-9
Electrical safetyCSA C22.2 No. 61010-1-12 / CSA C22.2 No. 61010-1-201
UL 61010-1 / UL 61010-1-201
Emitted interferenceEN 61000-6-4, FCC Part 15 Subpart B, ICES-001, AS/NZS CISPR 11
Noise immunityEN 61000-6-2 , EN 61131-2 , EN 61131-9
Shock resistanceEN 60068-2-27
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humiditymax. 95 %
Altitude0 ... 2000 m
Shock and impact resistance15g, 11ms, half-sine
Vibration resistance5-8Hz, 3.5mm displacement, 8.4-150Hz, 1.0g acceleration
Mechanical specifications
Degree of protectionIP20
ConnectionPower Supply screw terminal
Fieldbus RJ45
Inputs/Outputs screw terminal
Material
HousingPolyamide, UL94V-0
Mass272 g
Construction typeCabinet module
MountingDIN mounting rail

Documents: ICE2-8IOL-K45S-RJ45

ManualsIdiomaTipo de archivoTamaño
ManualENGPDF27177 KB
HandbuchGERPDF19017 KB

CAD+CAE: ICE2-8IOL-K45S-RJ45

CADTipo de archivoTamaño
3-D model in IGS format / 3-D-Modell im IGS-FormatIGS51365 KB
3-D model in STP format / 3-D-Modell im STP-FormatSTP17535 KB

Approvals+Certificates: ICE2-8IOL-K45S-RJ45

Statements of complianceNúmero de CertificadoTipo de archivoTamaño
EU-Declaration of conformity / EU-KonformitätserklärungDOC-4275BPDF258 KB
Certificates
Canada, USA UL ULE360395LINK---
KoreaR-R-PF1-C0106PDF318 KB
Worldwide IO-Link Manufacturer DeclarationCERT-5231APDF56 KB

Commissioning: ICE2-8IOL-K45S-RJ45

Commissioning filesIdiomaTipo de archivoTamaño
AOI (Add On Instruction) files for RSLogix 5000 / AOI (Add On Instruction) Dateien für RSLogix 5000ALLZIP2070 KB

Software: ICE2-8IOL-K45S-RJ45

Software ToolsLiberar InfoTipo de archivoTamaño
EtherNet/IP EDS files ICE2 modules / EtherNet/IP EDS-Dateien ICE2 Module11/2020ZIP33 KB
PortVision DX v5.02 / PortVision DX v5.022020-03ZIP26026 KB

Productos asociados: ICE2-8IOL-K45S-RJ45

Accessory of
Absolut rotary encoder of the innovative Pure Line, Recessed hollow shaft, IO-Link Interface for process data, parameterization and diagnosis, Suitable for condition monitoring, Measuring range, direction of rotation and switching signals programmablefa
Absolut rotary encoder of the innovative Pure Line, Solid shaft, IO-Link Interface for process data, parameterization and diagnosis, Suitable for condition monitoring, Measuring range, direction of rotation and switching signals programmablefa
Absolut rotary encoder of the innovative Pure Line, Recessed hollow shaft, IO-Link Interface for process data, parameterization and diagnosis, Suitable for condition monitoring, Measuring range, direction of rotation and switching signals programmablefa
Absolut rotary encoder of the innovative Pure Line, Solid shaft, IO-Link Interface for process data, parameterization and diagnosis, Suitable for condition monitoring, Measuring range, direction of rotation and switching signals programmablefa
Matching System Components
HF read/write station with IO-Link in accordance with ISO 15693fa
Accessories

Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable greyfa

Female cordset single-ended M12 straight A-coded, 4-pin, PVC cable greyfa

Female cordset single-ended M12 angled A-coded, 4-pin, PUR cable greyfa

Female cordset, M12, 4-pin, PVC cablefa

Female cordset, M8, 4-pin, PUR cablefa

Female cordset, M8, 4-pin, PUR cablefa

Female cordset single-ended M8 straight A-coded, 3-pin, PVC cable greyfa

Female cordset single-ended M8 angled A-coded, 3-pin, PVC cable greyfa
Network cable RJ-45, Category 5fa