1 axis acceleration sensor, E1-Type approval, Analog output 4 mA ... 20 mA, Fixed evaluation limits , High shock resistance, Teachable zero point, Measuring range -2 g ... +2 g, Increased noise immunity 100 V/mfa
2 axis acceleration sensor, E1-Type approval, Analog output 4 mA ... 20 mA, Fixed evaluation limits , High shock resistance, Teachable zero point, Measuring range -2 g ... +2 g, Increased noise immunity 100 V/mfa
Ej tillgänglig för köp: For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Non-hazardous area: screw terminals, black, Number of modules: 8, Number of channels per module: 2 , 4, Signal type: Universal, Manufacturer: Universal, Control system type: Universalpa
Ej tillgänglig för köp: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Ej tillgänglig för köp: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Ej tillgänglig för köp: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Ej tillgänglig för köp: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Ej tillgänglig för köp: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Ej tillgänglig för köp: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Ej tillgänglig för köp: 2-channel isolated barrier, 24 V DC supply (loop powered), Output 45 mA at 15 V DC, Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 18 ... 30 V DC , loop powered, Type: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarm, Field device [3]: 2 x visual alarm, Voltage: ≥ 15 Vpa
Ej tillgänglig för köp: 2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 18 ... 30 V DC, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarmpa
Ej tillgänglig för köp: 2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 18 ... 30 V DC, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarmpa
Withtheirflexibilityandmodularity, theVOS2-DuniversalvisionsensorsoffertheperfectsolutionforyourvisionapplicationLearnmoreaboutthecomponentsandsoftwareoftheVOSsensorseries ... measures―with5megapixelsandatthesametimeUniversella2D-visionssensorer i VOS-serienVOS-enheternasomfattandeuppsättning med integreradevisualiseringsverktyg kan kombinerasflexibelt så att en mängd olika automationsuppgifter inom fältet för 2D ...
SmartRunner3-D är den senaste3D-visionssensorn som finns tillgänglig med time-of-flight- och stereovisionsteknikLäs mer om det ... fullresolution / upto1m/sInterfaceGigabitEthernetTCP/IPGigabitEthernetTCP/IPDimensions165x67x56mm (WxHxD) / appr. 800gr. 165x67x56mm (WxHxD) / appr. 800gr. Ambientlightsuppression >20klux >100kluxRawimagesize1300 (H) x ...
TheML100sensorcombinesallsophisticatedphotoelectricfunctionalprinciples in asimple, rectangularminiaturehousingdesigntosolveallkindsofdemandingautomationtasksDiscovertheversatilesensorseries ... detekteringML100-6-IRKontrastinställning för upptäckt av glas eller lågkontrastML100-55-GGenomstrålandesensorer För standardtillämpningarM100/MV100-RTUtökadräckvidd för tillämpningar med långräckviddML100/MV100-RT/35Infrarött (IR) ljus ...
IIoT (IndustrialInternetofThings) fungerar bäst med den mest omfattandesensorinformationen som är möjlig på fältnivåLärkännaPepperl+Fuchs som leverantör av heltäckandeIIoT-lösningar med sensorteknik och programvara ... och plattformar. Programvarubaseradetjänster som tillhandahålls av våra IT-partnerskaparmervärde för våra kunder. IIoT-programvaruleverantörer vi samarbetar med … AmazonWebServicesAVEVABoschConnectedIndustryGEDigitalNeoceptionPTCSAPProgramvaraAG ...
Från tillförlitligskivdetektering till exaktPCB-positionering – upptäck vår omfattandeproduktportfölj för elektronikindustrin ... och uppgradera er fabrik för Industri4.0 med intelligentsensorteknik från Pepperl+Fuchs! Solcellsproduktion1) TillförlitligskivdetekteringSkivtestningutförs under tillverkning av halvledarenheter för att förhindradefektakretsar. Den kapacitivasensornF46 ...
Det digitalaKanban-hanteringssystemet från Pepperl+Fuchs, BoschConnectedIndustry och Neoceptionmöjliggörsmartlagerhantering ... Kanbanmanagementsystemandhowyoucanbenefitfromthisuniquesolution. RapportHämta nu utan kostnad! Vill du få ytterligaredjupgåendeinformation om digitalisering av Kanban-system? TobiasKehl, DigitalizationEngineer på Neoception, har skrivit ...
TheUSi-safetyultrasonicsensorsystemisbreakingnewgroundforsafetyapplications—whether in challenging, dustyenvironmentsor in outdoorareasLearnmoreabouttheUSi-safetyultrasonicsensorsystem ... reliablyprotectedusingstate-of-the-artultrasonictechnologyandalloftheadvantagesthisbrings. IntelligentDesignforEverySituationAminiaturesensorunitdetachedfromthecontrolinterfaceallowstheUSi-safetytobeusedeven in confined ...
Universalbarriärengerfullständigflexibilitet och sätternyastandarder genom att automatisktanpassa sig till i stort sett alla typer av fältingångssignaler och DCS-/ESD-system I/O ... reservkomponenternabetydligt mindre plats eftersom en endamodul kan lagrasuniversellt, oavsettsignaltyp. Nynivå av flexibilitetPepperl+FuchsHiC2441universalbarriärtarhänsyn till skillnader i signalkrav, och de tidigare begränsningarna är ett minneblott ...
UC18GS-serien från Pepperl+Fuchs har bokstavligttalat allt i fråga om funktioner och kombinerar allt du kan förvänta dig av en toppmodernultraljudssensor ... individualisering av produktautomatiseradproduktion i batchstorlek1 är möjlig viaIO-Link. Läs mer Exempel på tillämpningarAnpassningsbarnivåmätning i trångautrymmenUltraljudsgivare i UC18GS-serienkännersäkert av fyllnadsnivån för vätskor och granulat ...
WCS är avsedd för tillämpningar med extremaomgivningsförhållanden eller särskiltlångaavstånd ... , sluttningar, avbrott eller omkopplare. FlexibelintegreringPositionsvärdet kan överförasdirekt från läshuvudet till styrenhetenvia ett antalintegreradegränssnitt, t.ex. RS-485, SSI, CANopen, PROFINET eller Ethernet. Det finns ett brettutbud ...
31-40/916Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.