Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 120 mm, Parameterisable measuring range, Analog current or voltage output, programmable, Switching element function: Analog current or voltage output, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: current output 4-20 mA voltage output 0 - 5 V DC 0 ... 10 V DC , programmablefa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 120 mm, Parameterisable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable 2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)fa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 120 mm, Parameterisable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable 2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)fa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 14 mm, Analog output 0 ... 10 V, Output polarity: DC, Type of voltage: DC, Interface type: IO-Link, Output type: Push-pull (4 in 1) output , short-circuit protected, Output type: voltage output 0 ... 10 V, UL approval: cULus Listed, General Purpose, Class 2 Power Source, Connection type: M8 connector, 4-pin, Housing material: PA 6, Degree of protection: IP67fa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 14 mm, Analog output 0 V ... 5 V, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link, Output type: voltage output 0 ... 5 V, UL approval: cULus Listed, General Purpose, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector, 4-pin, Housing material: PA 66, Degree of protection: IP67fa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 40 mm, Parameterisable measuring range, Analog current or voltage output, programmable, Switching element function: Analog current or voltage output, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: current output 4-20 mA voltage output 0 - 5 V DC 0 ... 10 V DC , programmablefa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 40 mm, Parameterisable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable 2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)fa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 40 mm, Parameterisable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable 2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)fa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 80 mm, Parameterisable measuring range, Analog current or voltage output, programmable, Switching element function: Analog current or voltage output, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: current output 4-20 mA voltage output 0 - 5 V DC 0 ... 10 V DC , programmablefa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 80 mm, Parameterisable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable 2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)fa
Pepperl+Fuchs joined with partners to develop solutions that make valuable additional data from field devices centrally available—whether in the control room, in cloud-based systems, or even on mobile+Fuchs subsidiary Neoception develops innovative software solutions and industrial IoT services that are specially tailored to our customers' individual business processes and requirements. Neoception solutions allow field devices to be smoothly