1-channel, Field mount module, ½ NPT thread, Stainless steel housing, Max. surge current (8/20 µs) 20 kA, 500 V isolation from earth, Suitable for hazardous area, Up to SIL 3 acc. to IEC/EN 61508pa
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 relay contact outputs, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC bus powered via Termination Board, Field device: NAMUR sensor, Field device [2]: volt-free contactpa
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 relay contact outputs, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC bus powered via Termination Board, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (NO contact), Fault indication outputpa
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contactpa
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detectionpa
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connectionpa
2-channel isolated barrier, 24 V DC supply (loop powered), Logic input 15 V DC ... 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: 15 ... 30 V DC , loop powered, Type: 2 x logic input, Type: 2 x relay (change-over contact)pa
1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DCpa
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connectionpa
1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART-IP and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Signal: 2 x 4 ... 20 mA, Line fault detectionpa
Not available for purchase: 21.5 inch (54.6 cm) remote monitor, Thin Client solution (with VisuNet RM Shell firmware), 21.5" (54.6 cm); 1920 x 1080 Full HD, 16:9 aspect ratio widescreen formatting to match engineering stations, Full HD Resolution, Stainless steel housing with a surface finish of ≤ 0.8 µm, Easy-to-clean design that complies with GMP guidelines, IP65 rating of the entire systempa
Not available for purchase: 22 inch (55.9 cm) remote monitor, Thin Client solution (with VisuNet RM Shell firmware), 22 inch monitor (55.9 cm), Stainless steel housing with a surface finish of ≤ 0.8 µm, Easy-to-clean design that complies with GMP guidelines, IP65 rating of the entire systempa
Not available for purchase: WCS Bus terminal, Compact terminal housing, For the conntion of a reading head via spur line, Optimal connection of data wires and shieldfa
Not available for purchase: 1-channel, Installation in Zone 1, Zone 21, and Class I Div. 1, WirelessHART Adapter, Cast aluminum housing, Battery operated, Also supplies field device, Input 2-wire HART transmitters and 2-wire HART current sources, Output WirelessHART wireless interface, Direct mounting on HART or 4 mA ... 20 mA field device, Rotatable antennapa
Not available for purchase: Cast aluminum housing, Loop powered, Direct mounting on HART or 4 mA ... 20 mA field device, Encapsulated antenna, Up to 8 field devices in multidroppa
Not available for purchase: Installation in Zone 0, 20, Installation in Class I, II, Division 1, Installation in Class III, Installation in Class I, Division 2, Ex i circuits for Ex i field devices, Cast aluminum housing, Loop powered, Direct mounting on HART or 4 mA ... 20 mA field device, Encapsulated antenna, Up to 8 field devices in multidroppa
Not available for purchase: Installation in Zone 1, 21, Installation in Class I, II, Division 1, Installation in Class III, Ex d housing for Ex d field devices, Cast aluminum housing, Loop powered, Direct mounting on HART or 4 mA ... 20 mA field device, Encapsulated antenna, Up to 8 field devices in multidroppa
In autonomous transport, the direction of travel and the side areas of AGVs must be monitored in order to avoid any collision with people and objects. The USi-safety ultrasonic sensor systems reliably detect all obstacles in a defined safety area.Reliable Lateral Protection for Autonomous Transport of Large Tanks with USi-safety Unique Ultrasonic Sensor System Meets Requirements for PL d The Application In the chemical industry, tanks as long as 20 meters can be moved around the site with standard, category 3 PL d . The Solution USi-safety ultrasonic sensor system Several USi-safety ultrasonic sensors are distributed on each side of the vehicle. The very compact sensor unit can be mounted in places where other types of sensor would not fit