Ex d certified, Aluminum alloy, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Thermo-resistant tempered glass windowpa
FO Splice Boxes in Stainless Steel with Return Flange
Safe protection of fiber optic cable splices in hazardous areas, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex op pr and Ex tb certified , Stainless Steel enclosure, Up to 8 splice trays, 12 fusion-type splices per tray, Wide range of cable glands and stopping plugs, Return Flange Sealing provides Drain Channel, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 65 mA at 9.8 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: 20 ... 35 V DC , loop powered, Type: field device supply, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarm, Current: ≤ 65 mA, Voltage: ≥ 9.8 Vpa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: logic input, Field device: 2 x Valve, Field device [2]: 2 x audible alarm, Field device [3]: 2 x visual alarm, Current: ≤ 45 mA, Voltage: ≥ 11.7 Vpa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (bus powered), Current output up to 650 Ω load, SMART I/P and valve positioners, Line fault detection (LFD), Accuracy 0.1%, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 18 mm, Number of channels: 2-channel, Transfer direction: to the field, HART communication, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC bus powered via Termination Board, Signal: 2 x 4 ... 20 mA, Line fault detection, Field device: 2 x I/P converterspa
Not available for purchase: 4-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 4 relay contact outputs, Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508, Housing width: 18 mm, Number of channels: 4-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20.4 ... 30 V DC bus powered via Termination Board, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 4 x relay (NO contact), Fault indication outputpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Housing width 12.5 mm, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: loop powered, Type: field device supply, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarm, Current: ≤ 45 mA, Voltage: ≥ 12 Vpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: loop powered, Type: field device supply, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarm, Current: ≤ 45 mA, Voltage: ≥ 12 Vpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters, Output for 4 mA ... 20 mA or 1 V ... 5 V, Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, HART communication, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: 2-wire transmitter, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mA (current source)pa
Not available for purchase: 1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 16 V DC ... 30 V DC, non-polarized, Fail-safe relay contact output, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: 0-signal: 0 ... 5 V DC , loop powered 1-signal: 16 ... 30 V DC , loop powered, Type: 1 x logic input, Type [2]: field device supply, Type: 3 x relay (NO contact)pa
Not available for purchase: 2-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/4 mA ... 20 mA, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508, Housing width: 20 mm, Number of channels: 2-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Field device: 2-wire transmitter, Signal: 0/4 ... 20 mA, Input signal: 0/4 ... 20 mA, Signal: 2 x 0/4 ... 20 mA (current source)pa
SMART Transmitter Power Supply, Output Current Sink
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink, Terminal blocks with test sockets, Up to SIL3 acc. to IEC 61508, Housing width: 20 mm, Number of channels: 1-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 3, Rated voltage: 20 ... 35 V DC, Field device: 2-wire transmitterpa
In autonomous transport, the direction of travel and the side areas of AGVs must be monitored in order to avoid any collision with people and objects. The USi-safety ultrasonic sensor systems reliably detect all obstacles in a defined safety area.Reliable Lateral Protection for Autonomous Transport of Large Tanks with USi-safety Unique Ultrasonic Sensor System Meets Requirements for PL d The Application In the chemical industry, tanks as long as 20 meters can be moved around the site with standard, category 3 PL d . The Solution USi-safety ultrasonic sensor system Several USi-safety ultrasonic sensors are distributed on each side of the vehicle. The very compact sensor unit can be mounted in places where other types of sensor would not fit