Display Unit DPU1200-J2-19S*

DPU1200-J2-19S*
  • 10 point multi-touch sensor option allows design of modern user interfaces
  • Highly robust against cleaning agents and solvents due to seamless glass design
  • Optimized design for an easy cleanability
  • Low-power consumption and heat dissipation due to LED backlight technology

注: Pepperl+Fuchs GmbH(旧社名)で発行された証明書・適合宣言書などすべての製品関連文書は、Pepperl+Fuchs AG(新社名)にそのまま適用されます。

データシート(PDF):


技術データ  DPU1200-J2-19S*

型番
Display Unit
Supply
Power consumptionaverage: 22 W
at maximum brightness: max. 25 W
Indicators/operating means
Display
TypeLC display with LED backlight Optically bonded
Screen size48.26 cm (19 inch)
Resolution1280x1024 (SXGA) , Aspect ratio 5:4
Color depth16.7 Mio.
Contrast ratio1000:1 (typical)
Brightness450 cd/m2
Viewing angle170° horizontal , 160° vertical
Life spanback lamp life: 50.000 hrs typical half life , at 25 °C (77 °F)
Input devices
Touch screenoptional: projective capacitive, 10 finger multi-touch, glove-friendly
Interface
Interface typeinterface v1.0 from Pepperl+Fuchs for computing units from Pepperl+Fuchs
Bluetooth v4.0 , communication distance up to 30 m in open terrain (optional) , transmission power : +8 dBm
Transmitter frequency2.402 ... 2.48 GHz
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
non-Bluetooth products only
Radio and telecommunication terminal equipment
Directive 2014/53/EUEN 301 328 V2.1.1
EN 301 489-1 V2.1.1
EN 301 489-17 V3.1.1
Bluetooth products only
RoHS
Directive 2011/65/EU (RoHS)EN 50581:2012-09
Ambient conditions
Operating temperature-20 ... 50 °C (-4 ... 122 °F)
Storage temperature-20 ... 60 °C (-4 ... 140 °F)
Relative humidity93% at 40°C, non-condensating, according to EN 60068-2-78
Shock resistance18 shocks 15 g , 11 ms all axis, IEC 60068-2-27
Vibration resistance10 ... 150 Hz, ± 0.075 mm, 1 G, 10 cycles per axis according to EN60068-2-6
Mechanical specifications
Degree of protectionIP66 ( when mounted on the TCU or PCU from Pepperl+Fuchs )
Material
Surfacefront: glass (optional with stainless steel bezel)
Back side: powder coated aluminum
Massapprox. 11 kg
Dimensions524 mm x 453 mm x 35 mm
Data for application in connection with hazardous areas
EU-type examination certificateBVS 16 ATEX E 081 X
MarkingEx-Hexagon II 3G Ex ec IIC T4 Gc
Ex-Hexagon II 3D Ex tc IIIC T80 °C Dc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013, EN 60079-7:2015, EN 60079-31:2014
International approvals
IECEx approvalIECEx BVS 16.0061X
Approved forEx ec IIC T4 Gc
Ex tc IIIC T80 °C Dc
StandardsIEC 60079-0:2011, IEC 60079-7:2015, IEC 60079-31:2013

Classifications

SystemClasscode
ECLASS 13.027330201
ECLASS 12.027330201
ECLASS 11.027330201
ECLASS 10.0.127330201
ECLASS 9.027330201
ECLASS 8.027339090
ECLASS 5.127242402
ETIM 9.0EC001428
ETIM 8.0EC001428
ETIM 7.0EC001428
ETIM 6.0EC001428
ETIM 5.0EC001428
UNSPSC 12.139121106

Details: DPU1200-J2-19S*

Product Documentation: DPU1200-J2-19S*

Language Selection:
Safety and Security Documentation言語ファイルタイプファイルサイズ
Instruction ManualENGPDF174 KB
Manuals
Manual DPU1100-* / DPU1200-*ENGPDF5243 KB

Approvals: DPU1200-J2-19S*

Language Selection:
Certificates認証番号言語ファイルタイプファイルサイズ
China SITIIAS CCC Ex Certificate2020322309003367 (Singapore)ALLPDF2219 KB
EU DEKRA EXAM ATEX Category 3 D ATEX Category 3 GBVS 16 ATEX E 081 XALLPDF19457 KB
IECEx Certificate of ConformityIECEx BVS 16.0061XALLLINK---
Declaration of Conformity
EU Declaration of Conformity (Pepperl+Fuchs)DOC-3337DALLPDF231 KB
EU Declaration of Conformity (Pepperl+Fuchs)DOC-3096FALLPDF242 KB

関連製品: DPU1200-J2-19S*

Accessories
AC Power Supply, Certified for ATEX and IECEx Zone 2/22, Galvanic isolation between input and output, Provides an output power up to 80 W at 24 V DC, Fully IP66 ratedpa
DC Power Supply, Certified for ATEX and IECEx Zone 2/22, Galvanic isolation between input and output, Provides an output power up to 80 W at 24 V DC, Fully IP66 ratedpa