FB8222B.1.EL 技术数据
| Connection | backplane bus | |
| Nominal voltage | 12 V DC , only in connection with the power supplies FB92** | |
| Power dissipation | 4.24 W | |
| Power consumption | 4.24 W |
| Fieldbus type | PROFINET |
| Connection type | M12 , via front connector | |
| Transfer rate | 10BASE-T, 100BASE-TX 100 MBit/s | |
| Station connection | directly to PCS or PLC or via hubs or switches | |
| Cable type | SFTP in accordance with ISO/IEC 11801 for Cat 5e or better | |
| Bus length | max. 100 m per link | |
| Addressing | DHCP or fixed IP address | |
| Ethernet address | IP V4 address (factory standard setting: 0.0.0.0, auto IP, DHCP) | |
| Supported I/O modules | FB1x01*…FB1x03*, FB1x08*, FB1x09*, FB2x01*...FB2x17*, FB3x01*…FB3x06*, FB4x01*, FB4x02*, FB4x04*…FB4x06*, FB5x01*, FB5x02*, FB5x04*…FB5x06*, FB6x01*, FB6x05*, FB6x06*, FB6x08*, FB6x10*…FB6x17*, FB7x04 | |
| PROFINET conformance class | CC B |
| Connection | backplane bus |
| Ethernet/other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 32 V DC (SELV/PELV) | |
| RS 485 interface/other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V DC | |
| Insulation voltage | 1500 V AC acc. to IEEE 802.3u |
| Power supply, internal bus/other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 30 V DC |
| LED indication | See below in the front view |
| Electromagnetic compatibility | |||||
| |||||
| Electromagnetic compatibility | NE 21 | |
| Degree of protection | IEC 60529 | |
| Environmental test | EN 60068-2-14 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Damaging gas | EN 60068-2-42 | |
| Relative humidity | EN 60068-2-78 |
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Relative humidity | 95 % non-condensing | |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance | |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
| Degree of protection | IP20 (module) , a separate housing is required acc. to the system description | ||||||||||
| Connection | via backplane | ||||||||||
| Mass | approx. 965 g | ||||||||||
| Dimensions | |||||||||||
| |||||||||||
| EU-type examination certificate | PTB 19 ATEX 2007 U | ||||
| |||||
| Directive conformity | |||||
| |||||
| ATEX approval | PTB 19 ATEX 2007 U | |||||||
| IECEx approval | ||||||||
| ||||||||
| System information | The module may be installed only in the associated backplanes FB9262BP*.2 in Zone 1, Zone 2, or outside the hazardous area. Observe the corresponding EC-type examination certificate. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |