选择您所在的国家/地区
FB6305* Relay output
主要优势一览
- 4-channel
- Outputs wired to Ex e terminals
- Installation in suitable enclosures in Zone 1 or Zone 21
- Positive or negative logic selectable
- Simulation mode for service operations (forcing)
- Permanently self-monitoring
- Output with watchdog
- Module can be exchanged under voltage (hot swap)
显示详情






注意
在转换前以倍加福有限公司或倍加福股份公司名义发布的所有产品文档(如证书、符合性声明等)也适用于倍加福欧洲公司。
EN
- EN
- DE
FB6305* 技术数据
| Connection | backplane bus | |
| Rated voltage | Ur | 12 V DC , only in connection with the power supplies FB92** |
| Power consumption | 1.2 W |
| Connection | backplane bus | |
| Interface | manufacturer-specific bus to standard com unit |
| Number of channels | 4 | |||||||||||||
| Connection | wire ends 1/9 (white), 2/10 (brown), 3/11 (green), 4/12 (yellow), 5/13 (grey), 6/14 (pink), 7/15 (blue), 8/16 (red) | |||||||||||||
| Minimum load | 1 V , 1 mA | |||||||||||||
| Relay | ||||||||||||||
| ||||||||||||||
| Response time | 20 ms (depending on bus cycle time) | |||||||||||||
| Contact Material | AgPd gold plated | |||||||||||||
| Watchdog | within 0.5 s the device goes in safe state, e.g. after loss of communication | |||||||||||||
| LED indicator | LED green: supply LED red: communication fault |
| Electromagnetic compatibility | |||||
| |||||
| Low voltage | |||||
| |||||
| Electromagnetic compatibility | NE 21 | |
| Degree of protection | IEC 60529 |
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Relative humidity | 95 % non-condensing | |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 50 m/s2, number of shock directions 6, number of shocks per direction 100 | |
| Vibration resistance | frequency range 5 ... 500 Hz, amplitude 5 ... 13.2 Hz ± 1.5 mm, 13.2 ... 100 Hz 1g, sweep rate 1 octave/min, duration 10 sweeps 5 Hz - 100 Hz - 5 Hz | |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
| Degree of protection | IP20 (module) , a separate housing is required acc. to the system description | |
| Connection | wire ends or shielded cable tail wiring connection: separately covered Ex e terminals required | |
| Mass | approx. 750 g | |
| Dimensions | 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch) |
| EC-Type Examination Certificate | PTB 97 ATEX 1074 U | ||||
| |||||
| Galvanic isolation | |||||
| |||||
| Directive conformity | |||||
| |||||
| ATEX approval | BVS 11 ATEX E 093X | |||||||||||||
| EAC approval | Russia: RU C-IT.MIII06.B.00129 | |||||||||||||
| Marine approval | ||||||||||||||
| ||||||||||||||
相关页面