选择您所在的国家/地区

转至全球网站

停售

CMCA* Corrosion Monitoring CorrTran AQUA

主要优势一览

  • Please see Metal Samples for purchase: http://www.alspi.com
  • Corrosion can now be a multivariable process control signal
  • No more reactive "coupon" corrosion monitoring
  • Install in an existing coupon rack
  • 2-wire, 4 mA ... 20 mA transmitter, HART interface
  • General corrosion, localized corrosion (pitting), and conductance monitoring via HART
  • Optional local LCD

显示详情

注意

在转换前以倍加福有限公司或倍加福股份公司名义发布的所有产品文档(如证书、符合性声明等)也适用于倍加福欧洲公司。

EN
  • EN
  • DE

CMCA* 技术数据

Measured variablecorrosion (general and localized) and conductance
Electrical connection4 ... 20 mA with HART, 2-wire
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F) (with display: -10 °C ... 50 °C [14 °F... 122 °F])
Process conditions
Process temperaturestainless steel probe: max 260 °C (500 °F)
epoxy glass probe: max. 65 °C (149 °F)
Process pressure (static pressure)stainless steel probe max:
- adjustable: 102 bar (1500 psi)
- fixed: 206 bar (3000 psi)
epoxy glass probe:
- max: 7 bar (100 psi)
Flowmax. 6.1 m/s (20 fps) (finger electrodes)
Degree of protectionIP66, NEMA 4X
Massapprox. 500 g, transmitter housing
(approx. 600 g with display)
Materialhousing: ABS
probes: stainless steel 1.4401/316L or epoxy glass, fill material epoxy
end cap seal: glass or epoxy
electrode material: see references to Electrode material guide
o-ring: Viton (standard) or Kalrez (on request)
一般说明

相关页面

您是否正在寻找更多信息?请随时通过相关页面了解详情。