Línea de servicio de Sensores Industriales
Atención al cliente para protección contra explosiones

RFID Transponder IQC21-50F-T10

IQC21-50F-T10
  • Operating frequency 13.56 MHz
  • With extended temperature range up to 220 °C (428 °F)
  • Conforms to ISO 15693
  • 896 bits memory available
  • Readable and writable from both sides
  • Degree of protection IP68
  • Mounting holes for simple installation

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Descargue la hoja de datos completa en PDF::


Extracto de la hoja de datos: Información técnica del  IQC21-50F-T10

Descripción del producto
Data carrier
General specifications
Operating frequency13.56 MHz
Transfer rate26 kBit/s
Memory
Chip TypeI-CODE SLI (NXP)
EEPROM896 Bit
UID64 Bit
Memory organization4 bytes/block
Read cyclesunlimited
Write cycles> 100000
Data retention period10 years at 55 °C (131 °F)
Directive conformity
Radio equipment
Directive 2014/53/EUEN 300330
RoHS
Directive 2011/65/EU (RoHS)EN 50581
Standard conformity
Degree of protectionEN 60529
RFIDISO/IEC 15693-1
ISO/IEC 15693-2
ISO/IEC 15693-3
ISO/IEC 18000-3
Ambient conditions
Ambient temperature-40 ... 85 °C (-40 ... 185 °F)
Storage temperature-40 ... 220 °C (-40 ... 428 °F)
220 °C (493 K) for 1000 hours or 1500 cycles of 30 min
Climatic conditions100 % non-condensing
Mechanical specifications
Degree of protectionIP68
Material
HousingPPS
Installation
In airyes
Mass25 g
Construction typeRectangular type

Approvals+Certificates: IQC21-50F-T10

Statements of complianceNúmero de CertificadoTipo de archivoTamaño
EU-Declaration of conformity / EU-KonformitätserklärungDOC-0392BPDF167 KB

Productos asociados: IQC21-50F-T10

Accessory of

HF read/write head, ISO 15693, for IDENTControlfa

HF read/write head, ISO 15693, for IDENTControlfa

HF read/write head, ISO 15693, for IDENTControlfa
HF R/W system, ISO 15693fa
HF read/write head, ISO 15693, for IDENTControlfa
HF read/write head, ISO 15693, for IDENTControlfa
HF read/write head, ISO 15693, for IDENTControlfa
HF R/W system, ISO 15693fa
HF R/W system, ISO 15693fa
HF R/W system, ISO 15693fa
HF read/write station with IO-Link in accordance with ISO 15693fa
HF read/write station with IO-Link in accordance with ISO 15693fa
HF read/write station with IO-Link in accordance with ISO 15693fa
HF read/write head, ISO 15693, for IDENTControl, hazardous areasfa
Accessories
Spacers for code/data carrierfa
Visite el Hub RFID