Panoramica dei principali vantaggi
- Raw data for vibration acceleration a-Raw by means of BLOB transfer
- Frequency range up to 12 kHz with sampling rate up to 64 kHz
- Bearing status parameter according to DIN ISO 13373
- Vibration velocity in mm/s (rms) acc. to DIN ISO 10816/20816
- Vibration acceleration in g (rms) acc. to DIN ISO 10816/20816
- Additional temperature value output
- IO-Link Interface for process data, parameterization and diagnosis
- Rugged stainless steel housing
Mostra di più









Nota
Tutti i documenti relativi ai prodotti, come ad esempio certificati, dichiarazioni di conformità ecc., pubblicati prima della conversione con il nome Pepperl+Fuchs GmbH o Pepperl+Fuchs AG, si applicano anche a Pepperl+Fuchs SE.
EN
- EN
- DE
- ES
- FR
Dati tecnici di VIM32PP-E7DC8-0RE-IO-1V1401
| Type | Vibration sensor | ||||||||||||||||||||||
| Measuring technology | MEMS capacitive | ||||||||||||||||||||||
| Series | Performance Plus Line | ||||||||||||||||||||||
| Measured variable | Vibration velocity Vibration acceleration Bearing status parameter Crest factor Temperature | ||||||||||||||||||||||
| Measuring range | |||||||||||||||||||||||
| |||||||||||||||||||||||
| Measurement accuracy | Vibration velocity: ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s Vibration acceleration: ± 0.01 g (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 | ||||||||||||||||||||||
| Cross-sensitivity | < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis | ||||||||||||||||||||||
| Resolution | Vibration velocity: 0.01 mm/s Vibration acceleration: 0.01 g Bearing status parameter: 0.01 | ||||||||||||||||||||||
| Frequency range | Vibration acceleration a-raw: 0 ... 12000 Hz , by means of BLOB transfer Vibration velocity rms: 10 ... 1000 Hz , acc. to DIN ISO 10816/20816 , programmable Vibration acceleration rms: 10 ... 1000 Hz , acc. to DIN ISO 10816/20816 , programmable Vibration acceleration a-peak: 10 ... 10000 Hz Crest factor: 10 ... 10000 Hz Bearing status parameter: 10 ... 10000 Hz , acc. to DIN ISO 13373-3 | ||||||||||||||||||||||
| Averaging time | for v-rms: 2 s for a-rms: 2 s | ||||||||||||||||||||||
| Sampling rate | Vibration acceleration a-raw: 64 kHz , programmable Vibration velocity rms: 8 kHz Vibration acceleration rms: 8 kHz Vibration acceleration a-peak: 32 kHz Crest factor: 32 kHz Bearing status parameter: 32 kHz | ||||||||||||||||||||||
| MTTFd | 329 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % |
| Fusing | external fuse is required: 1 A , fast acting , 30 V DC | |
| Operating voltage | UB | 18 ... 30 V DC |
| Current consumption | max. 320 mA | |
| Power consumption | P0 | max. 10 W |
| Time delay before availability | tv | ≤ 3.6 s |
| Surge protection | up to 2 kV |
| Interface type | IO-Link (via C/Q = Pin 4) | |
| IO-Link revision | 1.1 | |
| Device profile | Identification and Diagnosis - I&D , BLOB transfer | |
| Process data | Input 24 Byte measurement channels: -rms value velocity - peak value acceleration - rms value acceleration - temperature - crest factor - bearing status parameter per measurement channel: - measurement value 2 Byte - scaling 8 Bit - switching signals 2 Bit status data | |
| Vendor ID | 1 (0x0001) | |
| Device ID | 5308673 (0x510101) | |
| Transfer rate | COM3 (230.4 kbits/s) | |
| Min. cycle time | 3.8 ms | |
| SIO mode support | yes | |
| Compatible master port type | Class A Class B (use 3-pole adapter or 3-wire cable) | |
| BLOB size | 1.28 MByte , programmable | |
| BLOB segments | 200 Byte per request and BLOB segment respectively |
| Output type | C/Q - Pin 4 in SIO mode (switching signal of the measured variable is programmable) | |
| Switching function | Normally open/closed (NO/NC) | |
| Operating current | ≤ 100 mA | |
| Short-circuit protection | yes |
| Output type | I/Q - pin 2 (parameterizable as analog current output or switching signal) - I: analog output for the measured variable, current 4 ... 20 mA - Q: switching signal of the measured variable is parameterizable, PNP normally open | |
| Switching function | Normally open/closed (NO/NC) | |
| Operating current | ≤ 120 mA for switching signal | |
| Voltage drop | < 2 V | |
| Output current | 4 ... 20 mA at analog output | |
| Load resistor | ≤ 500 Ω at analog output | |
| Short-circuit protection | yes |
| Degree of protection | DIN EN 60529, IP66, IP67 | |
| Shock resistance | DIN EN 60068-2-27, 60 g, 6 ms | |
| Vibration resistance | DIN EN 60068-2-6, 16.5 g, 10 ... 12000 Hz | |
| Vibration evaluation | DIN ISO 10816/20816 , DIN ISO 13373-3 |
| UL approval | ||||||||
| ||||||||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Connection type | plug | |||||||
| Housing material | Stainless steel 1.4305 / AISI 303 | |||||||
| Degree of protection | IP66 / IP67 only in connected state | |||||||
| Connector | ||||||||
| ||||||||
| Mass | approx. 100 g | |||||||
| Dimensions | ||||||||
| ||||||||