Seleziona il tuo paese

Vai al sito web globale

LFL2-BK-U-PUR10-EMS Float Switch

Panoramica dei principali vantaggi

  • Switch element: microswitch, mercury-free
  • Limit value detection for fluids
  • Ball design: high buoyancy
Product Compliance: Europe – CE
Approval symbol
Nota

Tutti i documenti relativi ai prodotti, come ad esempio certificati, dichiarazioni di conformità ecc., pubblicati prima della conversione con il nome Pepperl+Fuchs GmbH o Pepperl+Fuchs AG, si applicano anche a Pepperl+Fuchs SE.

EN
  • EN
  • DE

Dati tecnici di LFL2-BK-U-PUR10-EMS

SeriesLFL2-**-U
Construction typeball design
Contact loading250 V AC/3 A; 150 V DC/0.25 A resistive load; 60 V DC/1 A resistive load
Rated insulation voltage300 V
Pulse withstand voltage4 kV
Electrical life≥ 5 x 104 switching cycles
Low voltage
Directive 2014/35/EUEN 60947-5-1:2004 + Cor.:2005 + A1:2009
Degree of protectionIEC 60529:2001
Descriptionmicroswitch with switching ball, change-over contact
Equipment architectureThis device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.
CCC approvalCertified by China Compulsory Certification (CCC)
Installation conditions
Installation instructionsrange of application and minimum length between mounting and float:
≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluids
mounting:
The float switch is mounted by means of a counter weight or rods (e. g. float switch combination) from the top.
The pivot of the cable should always be horizontal.
Process conditions
Process pressure (static pressure)≤ 2 bar (29 psi) at 20 °C (68 °F)
Density≥ 0.6 g/cm3
Ambient temperature5 ... 70 °C (41 ... 158 °F)
Storage temperature-25 ... 70 °C (-13 ... 158 °F)
Altitude≤ 2000 m above MSL
Degree of protectionIP68
Cable
LengthL10 m
Materialfloat: PP (Polypropylene)
cable: PUR, highly flexible (3 x 0.50 mm2)
Switching pointswitch angle, measured against the horizontal:
- upper switch point 25° ±10°
- lower switch point 6° ±6°
Supplementary informationStatement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Note generali