Fabrika Otomasyonu
Proses Otomasyonu

Base for read/write station, plug-in connection U-P3-R4-V15

U-P3-R4-V15
  • Degree of protection IP67
  • Simple bus system with up to 30 units
  • Serial interface RS 485, addressable

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Tam veri sayfasını PDF olarak indirin:


Veri sayfası alıntısı: Teknik veriler  U-P3-R4-V15

Ürün Açıklaması
Base with addressable serial Interface RS 485
Indicators/operating means
DIP switchSetting the station address
bus connection
ON = active  OFF = non-active
Electrical specifications
Rated operating voltage20 ... 30 V DC , ripple 10 %SS , PELV
Power consumptionmax. 4 W with read/write head IPT*-FP
Galvanic isolation
Operating voltage/interfacefunctional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff
Interface
Physical RS-485, addressable , up to 30 bases , address 1 ... 30
ProtocolASCII
Transfer rate1200; 2400; 4800; 9600; 19200; 38400 Bit/s
Cable length≤ 1200 m
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67 according to EN 60529 with IPT*-FP
Connection5-pin, M12 x 1 connector
Material
Housingdiecast aluminum
Dimensions
Height29 mm
Width80 mm
Length114 mm

Classifications

SystemClasscode
ECLASS 13.027280492
ECLASS 12.027280490
ECLASS 11.027280490
ECLASS 10.0.127280490
ECLASS 9.027280490
ECLASS 8.027280490
ECLASS 5.127279212
ETIM 9.0EC002997
ETIM 8.0EC002997
ETIM 7.0EC002997
ETIM 6.0EC002997
ETIM 5.0EC003015
UNSPSC 12.131162301

Details: U-P3-R4-V15

Function

The base is used in combination with an upper part, the IPT*-FP read/write station. An addressable RS 485 interface is available. It is thus possible to create a simple bus connection with up to 30 subscribers.

The address is set and the terminating resistor for the bus is connected via DIP switches.

The read/write station is connected to a higher-order control system via the serial interface and receives the commands for writing and/or reading code or data carriers via this interface.

Product Documentation: U-P3-R4-V15

Dil Seçeneği:
Brief InstructionsDilDosya TipiDosya Boyutu
Instruction leaflet / BeipackzettelALLPDF388 KB
Manuals
Manual IPTx-FP with U-Px-R4-V15ENGPDF1139 KB

Design / Simulation: U-P3-R4-V15

Dil Seçeneği:
CADDilDosya TipiDosya Boyutu
CAD 3-D / CAD 3-DALLSTP511 KB
CAD Portal / CAD PortalALLLINK---

Approvals: U-P3-R4-V15

Dil Seçeneği:
Declaration of ConformitySertifika No.DilDosya TipiDosya Boyutu
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-3498BALLPDF107 KB

İlişkili Ürünler: U-P3-R4-V15

Matching System Components
LF R/W system, fully assembled as configuration and test stationfa
RFID Hub'ı ziyaret edin

RFID için bir bilgi bankası niteliği taşıyan özel "RFID Hub" web sitemizi ziyaret edin. Sık sorulan sorulara yanıt alın ve tipik RFID uygulamaları hakkında bilgi edinin…