Línea de servicio de Sensores Industriales
Atención al cliente para protección contra explosiones

RFID read/write device IQT1-18GM-IO-V1

IQT1-18GM-IO-V1
  • Operating frequency 13.56 MHz
  • IO-Link interface
  • Conforms to ISO 15693
  • Suitable for FRAM transponder
  • LEDs as function indicators
  • Read/write head with thread M18 x 1
  • Connection via V1 (M12 x 1) plug connection
  • Degree of protection IP67
  • For connection to IO-Link master

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Descargue la hoja de datos completa en PDF:


Extracto de la hoja de datos: Información técnica del  IQT1-18GM-IO-V1

Descripción del producto
HF RFID read/write device with IO-Link in accordance with ISO 15693
General specifications
Operating frequency13.56 MHz
Transfer rate26 kBit/s
Sensing range
Read distance0 ... 50 mm
Write distance0 ... 50 mm
Widthmax. 45 mm
UL File NumberE87056
MTBF140 a (Operation at +40 °C)
Indicators/operating means
LED red/greenGreen: power on
Flashing green: IO-Link communication
Flashing red/green: IO-Link communication interrupted
LED blue/yellowBlue: Write/read attempt performed
Yellow: Read/write tag detected
Electrical specifications
Rated operating voltage20 ... 30 V DC , ripple 10 %SS
No-load supply current≤ 70 mA (at 24 V DC)
Power consumption≤ 2 W
Interface
Interface typeIO-Link
IO-Link revision1.1
Process dataInput 32 Byte
Output 32 Byte
Vendor ID1 (0x0001)
Device ID4194561 (0x400101)
Data transfer rateCOM3 (230.4 kbits/s)
Min. cycle time4 ms
SIO mode supportno
Compatible master port typeClass A
Class B
Directive conformity
Radio equipment
Directive 2014/53/EUEN 301489-1
EN 301489-3
EN 300330
EN 62368-1
EN 50364
RoHS
Directive 2011/65/EU (RoHS)IEC/EN 63000
Standard conformity
Degree of protectionEN 60529
Communication interfaceIEC 61131-9 / IO-Link V1.1.2
RFIDISO/IEC 15693-2
ISO/IEC 15693-3
ISO/IEC 18000-3
Approvals and certificates
UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure
FCC approvalThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Caution:
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
IC approvalThis device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
MIC approvalapproval not required
Radio approvalUSA: FCC IREIQT118GMIO
Canada: IC 7037A-IQT118GMIO
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67
Connectionconnector M12 x 1
Material
HousingPBT/stainless steel
Encapsulation compoundCY 221/HY 2966
Installationnon-flush
Distance between two heads≥ 80 mm
Massapprox. 25 g
Dimensions
Length63.5 mm
Diameter18 mm

Classifications

SystemClasscode
ECLASS 13.027280401
ECLASS 12.027280401
ECLASS 11.027280401
ECLASS 10.0.127280401
ECLASS 9.027280401
ECLASS 8.027280401
ECLASS 5.127280401
ETIM 9.0EC002998
ETIM 8.0EC002998
ETIM 7.0EC002998
ETIM 6.0EC002998
ETIM 5.0EC002998
UNSPSC 12.143211710

Details: IQT1-18GM-IO-V1

Informative Literature: IQT1-18GM-IO-V1

Seleccionar idioma:
LiteratureIdiomaTipo de archivoTamaño
Application Report - RFID Systems in Industrial Metal StampingENGPDF1773 KB

Product Documentation: IQT1-18GM-IO-V1

Seleccionar idioma:
Product informationIdiomaTipo de archivoTamaño
Installation and user instructions for offline parameterization of IO-Link sensorsENGPDF1788 KB
Manuals
ManualENGPDF2227 KB

Design / Simulation: IQT1-18GM-IO-V1

Seleccionar idioma:
CADIdiomaTipo de archivoTamaño
CAD 3-D / CAD 3-DALLSTP69 KB
CAD Portal / CAD PortalALLLINK---

Approvals: IQT1-18GM-IO-V1

Seleccionar idioma:
CertificatesNúmero de CertificadoIdiomaTipo de archivoTamaño
Canada Radio Approval7037A-IQT118GMIOALLPDF1829 KB
Canada, USA ULCoC UL-CA-L87056-31-61115002-0 / UL-US-L87056-11-61115002-0ALLPDF561 KB
IO-Link Manufacturer DeclarationCERT-4469ALLPDF160 KB
USA FCC ApprovalIREIQT118GMIOALLPDF127 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-3819BALLPDF110 KB
Simplified EU Declaration of Conformity / Vereinfachte EU-Konformitätserklärung   ALLPDF61 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-7036ALLPDF108 KB

Software: IQT1-18GM-IO-V1

Seleccionar idioma:
Device Description Files/DriversLiberar InfoTipo de archivoTamaño
IODD for IQT1 series / IODD für IQT1-Serie1.01.000 / 2018-02-22ZIP239 KB
Function block "IQT1_EasyMode" and "IO_Link_Device" for RFID head IQT1-...-IO-V1 with ICE3 IO-Link Master on Step 7 Classic / Funktionsbaustein "IQT1_EasyMode" und "IO_Link_Device" für RFID-Kopf IQT1-...-IO-V1 mit ICE3 IO-Link Master an Step 7 ClassicZIP8343 KB
Function block "IQT1_EasyMode" and "IO_Link_Device" for RFID head IQT1-...-IO-V1 with ICE3 IO-Link Master on TIA Portal / Funktionsbaustein "IQT1_EasyMode" und "IO_Link_Device" für RFID-Kopf IQT1-...-IO-V1 mit ICE3 IO-Link Master an TIA PortalZIP8675 KB
Function block "IQT1_EasyMode" and "IO_Link_Parameter" for RFID head IQT1-...-IO-V1 with EL6224 IO-Link Master on Beckhoff TwinCAT 3 / Funktionsbaustein "IQT1_EasyMode" und "IO_Link_Parameter" für den RFID-Kopf IQT1-...-IO-V1 mit EL6224 IO-Link Master an Beckhoff TwinCAT3ZIP21489 KB
Function blocks TIA Portal (S7-1200/1500) for the RFID device IQT1-xx-IO-V1 (IO-Link) when using the Expert Mode / Funktionsbausteine TIA Portal (S7-1200/1500) für das RFID-Gerät IQT1-xx-IO-V1 (IO-Link) bei der Verwendung des Expert ModesV2.0ZIP16117 KB
Software Tools
Add-On Instructions for RSLogix/Studio 5000. Reading and writing of Parameters to IQT1 RFID Heads and Easy and Expert mode(Function Blocks) Add-On Instructions to read and write RFID data to a tag. / Inbetriebnahmedatei_a5/2023ZIP31797 KB
IO-Link Offline Parameterization Tool / IO-Link Offline-ParametriertoolV1.00.006 / 2022-07-10ZIP96138 KB

Productos asociados: IQT1-18GM-IO-V1

Accessories

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Cordset M12 socket straight to M12 plug straight A-coded, 4-pin, PVC cable greyfa

Cordset M12 socket straight to M12 plug straight A-coded, 4-pin, PVC cable greyfa

EtherNet/IP IO-Link master with 8 inputs/outputsfa

PROFINET IO IO-Link master with 8 inputs/outputsfa
Ethernet IO-Link master with PROFINET S2 redundancyfa
Cordset M12 socket straight to M12 plug straight A-coded, 4-pin, PVC cable greyfa
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, push-in terminalsfa
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa
Ethernet IO-Link module with 8 inputs/outputsfa
Ethernet IO-Link module with 8 inputs/outputsfa
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, push-in connectorsfa
Dispositivo de lectura/escritura RFID IUT-F190-B40 con interfaz Ethernet industrial y API REST

Conozca el nuevo IUT-F190-B40, que está diseñado para rangos de detección medios y se puede integrar de forma rápida y sencilla en los sistemas TO y TI…

Visite el Hub RFID

Visite nuestro "Hub RFID: esta página web especial es una base de conocimientos sobre RFID. Obtenga respuestas a preguntas frecuentes y aprenda sobre las aplicaciones RFID más habituales...