Ikke tilgjengelig: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Ikke tilgjengelig: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Ikke tilgjengelig: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Ikke tilgjengelig: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Ikke tilgjengelig: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Ikke tilgjengelig: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Ikke tilgjengelig: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Ikke tilgjengelig: Diffuse sensor with measurement core technology, large housing design, background suppression and 3 more adjustable operating modes, IO-Link interface, 800 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable, Cost-optimized series for standard tasks, Sensing-by-ranging functionality, IO-Link interface for service and process data, PowerBeam transmitter LED, Large adjustment range can be precisely definedfa
Fitting ABB’s 800xA control system with physical layer diagnostics is easy with the free ADM package from Pepperl+Fuchs ... are eliminated and the required time for segment commissioning is reduced by up to 80 %. Expert system for fast troubleshooting For fieldbus experts: The embedded oscilloscope provides detailed insights Using the FieldConnex® Advanced Diagnostic ...
Se oversikt: Pepperl+Fuchs offers a wide range of photoelectric sensors designed for the convenient and safe operation of industrial doors, gates, escalators, elevators and lifts ... of people or vehicles to overhead industrial doors , or sensing between elevator doors is the topic, we have the products. Using various sensor technologies, we offer both manufacturers and users the broadest line of these powerful sensors. More ...
Se oversikt: Pepperl+Fuchs offers a comprehensive range of RFID systems, barcode and data matrix code products for object identification in automated manufacturing processes ... painting lines. The OIT high-temperature IDENT system uses metal code plates with a hole pattern that are evaluated using industrial imaging technology. ...
Se oversikt: Pepperl+Fuchs' Compact Power Hub feeds eight (8) FOUNDATION Fieldbus H1 segments with redundancy of power supplies ... service life . The motherboard is designed for DIN rail installation and vertical installation of cable channels for efficient wiring . All modules snap onto the motherboard without using any tools. In redundant configuration, the power supply modules can ...
Se oversikt: Com units for PROFIBUS and MODBUS RTU - Connect Remote I/O to Control System/ PLC/ PC ... for measured and setpoint values, the gateways transmit auxiliary variables, configuration and diagnostic data from HART-compatible field devices using the integrated HART-IP interface. Com units are available for different industrial communication protocols ...
A low Safety Integrity Level, or SIL requirement (SIL 1) means that only a comparably low risk reduction is necessary ... quantified using risk analysis methods that deliver results in the form of a SIL requirement . A low SIL requirement (SIL 1) means that only a comparably low risk reduction is necessary, whereas a higher SIL (for example SIL 3) requires a greater degree of ...
Se oversikt: Radio Frequency Identification Systems (RFID) from Pepperl+Fuchs are the preferred way to solve automatic identification tasks in demanding industrial environments ... identify RFID tags independently of stationary readers. This leads to a wide range of potential applications. Use our RFID handhelds to manually control quality or to verify maintenance work . Using a sophisticated mechanism, RFID read/write heads ...
Pepperl+Fuchs leverer et bredt utvalg produkter innen bransjen Print and Paper ... reduces operator workload and downtime Safe detection even on reflective surfaces Innovative image processing technology ensures reading of very large barcodes Reliable double sheet and splice detection Double sheet and splice detection using ultrasonic ...
Se oversikt: Pepperl+Fuchs offers vibration limit switches for liquid level measurement ... fluctuations in the physical properties of the medium. Operation mode The two paddles of a vibrating fork are actuated using a piezoelectric source. In air the vibrating fork vibrates at its resonance frequency. When it is immersed in rising liquid, the ...
Se oversikt: Accessories for AS-Interface include handheld programming tools, network evaluation software, flat cable, mounting bases, adapters & splitter boxes ... modules or even individual networks is particularly easy because the handheld is operated using one hand. AS-Interface diagnosis and parameterization tools AS-Interface analyzer The AS-Interface analyzer allows online monitoring of communication in the ...