Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Last ned komplett datablad som PDF:
Datablad utdrag: Tekniske data for
NBN5-11K8-N-V8
General specifications |
Switching function | Normally closed (NC) |
Output type | NAMUR |
Rated operating distance | 5 mm |
Installation | non-flush |
Assured operating distance | 0 ... 4.05 mm |
Output type | 2-wire |
Nominal ratings |
Operating voltage | 5 ... 15 V |
Switching frequency | 0 ... 2000 Hz |
Hysteresis | 0.05 ... 0.75 |
Current consumption | |
| Measuring plate not detected | min. 2.7 mA |
| Measuring plate detected | ≤ 1.8 mA |
Functional safety related parameters |
MTTFd | 8162 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Approvals and certificates |
UL approval | cULus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Mechanical specifications |
Connection type | Solder connection |
Housing material | PA |
Degree of protection | IP67 |
Dimensions | |
| Length | 6.5 mm |
| Diameter | 10 mm |
Classifications
System | Classcode |
ECLASS 13.0 | 27274001 |
ECLASS 12.0 | 27274001 |
ECLASS 11.0 | 27270101 |
ECLASS 10.0.1 | 27270101 |
ECLASS 9.0 | 27270101 |
ECLASS 8.0 | 27270101 |
ECLASS 5.1 | 27270101 |
ETIM 9.0 | EC002714 |
ETIM 8.0 | EC002714 |
ETIM 7.0 | EC002714 |
ETIM 6.0 | EC002714 |
ETIM 5.0 | EC002714 |
UNSPSC 12.1 | 39121550 |
Details:
NBN5-11K8-N-V8
Design / Simulation:
NBN5-11K8-N-V8
Approvals:
NBN5-11K8-N-V8