Niet beschikbaar voor verkoop: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Niet beschikbaar voor verkoop: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Niet beschikbaar voor verkoop: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Niet beschikbaar voor verkoop: Diffuse sensor with measurement core technology, large housing design, background suppression and 3 more adjustable operating modes, IO-Link interface, 800 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable, Cost-optimized series for standard tasks, Sensing-by-ranging functionality, IO-Link interface for service and process data, PowerBeam transmitter LED, Large adjustment range can be precisely definedfa
Naar overzicht: Pepperl+Fuchs offers a comprehensive range of RFID systems, barcode and data matrix code products for object identification in automated manufacturing processes ... painting lines. The OIT high-temperature IDENT system uses metal code plates with a hole pattern that are evaluated using industrial imaging technology. ...
Naar overzicht: Pepperl+Fuchs offers a wide range of photoelectric sensors designed for the convenient and safe operation of industrial doors, gates, escalators, elevators and lifts ... of people or vehicles to overhead industrial doors , or sensing between elevator doors is the topic, we have the products. Using various sensor technologies, we offer both manufacturers and users the broadest line of these powerful sensors. Meer Informatie ...
Naar overzicht: Kleurensensoren en contrastsensoren van Pepperl+Fuchs zijn ideaal voor gebruik als signaalomzetter, voor gebruik in de printindustrie, de verpakkingsindustrie, de voedings- en drankeni ... times, and insensitivity to fluctuations in height and angle on the material web. Color Sensors Unlike contrast sensors, which operate using a similar principle, color sensors operate on multicolored backgrounds with an exceptional degree of reliability ...
Naar overzicht: De ultrasone sensoren met diffuse en retroreflecterende werkingsprincipes van Pepperl+Fuchs hebben een zender en ontvanger in dezelfde behuizing ... protected using state-of-the-art ultrasonic technology and all of the advantages this brings. ...
Pepperl+Fuchs biedt een breed scala aan sensoren en sensorsystemen voor toepassingen in de grafische en papierindustrie ... using ultrasonic sensors has proven itself in the printing, paper, and packaging industry. Printing machine downtime and high repair costs due to double sheet events can now be eliminated due to the ultrasonic series UDC-18GM . Additionally, the UGB ...
Fieldbus: Commissioning with Advanced Diagnostic Tools The Advanced Diagnostic Module from Pepperl+Fuchs monitors the fieldbus physical layer during operation Measurements are accessible in the cont ... of accuracy. Only one translation from an analog to a binary value is performed – and the transmission of this binary value is ensured using checksums and other mechanisms common to any digital transmission. This leads to control loops acting with higher ...
The process industry is picking up on digital data transfer via fieldbus The advantages are clear: much less wiring saves costs and time during planning, installation and commissioning ... the shielding – The shielding has been neatly attached and insulated at each field device Switch on the fieldbus power supply and activate the control technology to actuate all field devices Carry out all measurements and store and document them using ...
41-47/47Artikelen per pagina:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.