Magnetic, non Contact, Clear function verification via two-color LEDs (red/green), Simple installation and adjustment using assistance functions reduce costs, Self-diagnostics including the magnetic wheel provide quality assurance, Internal intelligence provides easy setup and reliable operation , The elastomer coating of the magnetic wheel provides resistance to dirt as well as thermal and mechanical shock, Enclosure type: Rectangular type, Type of shaft: non-contactfa
1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for de-energized to safe function, Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC/EN 61508, Up to PL e acc. to EN/ISO 13849, Housing width: 20 mm, Number of channels: 1-channel, Diagnostics function, Line fault transparency, DTS function (de-energized to safe), Safety Integrity Level (SIL): SIL 3pa
1-channel signal conditioner, 24 V DC supply, Logic input 20.5 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for de-energized to safe function, Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC/EN 61508, Up to PL e acc. to EN/ISO 13849, Housing width: 20 mm, Number of channels: 1-channel, Diagnostics function, Line fault transparency, DTS function (de-energized to safe), Safety Integrity Level (SIL): SIL 3pa
1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Diagnostics function, Line fault transparency, ETS function (energized to safe), Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 26.4 V DCpa
1-channel signal conditioner, 24 V DC supply, Logic input 20.5 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Diagnostics function, Line fault transparency, ETS function (energized to safe), Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3pa
Software user interface for Advanced Diagnostic Modules, Simultaneous access to all ADMs of a plant, Embedded expert system gives pointed advice in clear text, Includes Commissioning Wizard, data historian, oscilloscope..., For FOUNDATION Fieldbus H1 and PROFIBUS PA, Automatic setup of diagnostic systempa
Fieldbus Power Hub, Motherboard for Gateway and Power Supply Modules
4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa
Indisponível para compra: Comprehensive diagnostics for the fieldbus physical layer, Mobile kit for the fieldbus professional, Precise measurements through passive circuits, For commissioning and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Europe, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk, Device coupler location [4]: Division 2 - high-power trunkpa
Indisponível para compra: Software user interface for Advanced Diagnostic Modules, Access to mobile ADM via USB-port, Embedded expert system gives pointed advice in clear text, Includes Commissioning Wizard, data historian, oscilloscope..., For FOUNDATION Fieldbus H1 and PROFIBUS PApa
Indisponível para compra: System integration kit for Advanced Diagnostics, PCS integration via Ethernet, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PApa
Indisponível para compra: Magnetic, Non Contact, Clear function verification via two-color LEDs (red/green), Simple installation and adjustment using assistance functions reduce costs, Self-diagnostics including the magnetic wheel provide quality assurance, Internal intelligence provides easy setup and reliable operation , The elastomer coating of the magnetic wheel provides resistance to dirt as well as thermal and mechanical shock, Output type: push-pull, incrementalfa
Indisponível para compra: Evaluation device for safety thru-beam sensors SLA12 and SLA29, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Operating reserve indication, Clearly visible LED functional display, 7-segment diagnostic display, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC, -15 %/+20 %fa
Indisponível para compra: Sensing range up to 20 m, 2, 3, and 4-beam design, Beam distance 300, 400 and 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Start/Restart disable , Degree of protection IP67, 7-segment diagnostic display, Operating reserve indication, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Indisponível para compra: Sensing range up to 20 m, 2, 3, and 4-beam design, Beam distance 300, 400 and 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Degree of protection IP67, 7-segment diagnostic display, Operating reserve indication, Connection via appliance socket M12 x b1, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Indisponível para compra: ATEX-approval for zone 2 and zone 22, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Safety outputs OSSD, external status displays OSSD, Start/Restart disable , 7-segment diagnostic display, Operating reserve indication, Degree of protection IP66, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Indisponível para compra: Sensing range up to 20 m, 2, 3, and 4-beam design, Beam distance 300, 400 and 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Start/Restart disable , Degree of protection IP67, 7-segment diagnostic display, Operating reserve indication, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Indisponível para compra: Sensing range up to 20 m, 2, 3, and 4-beam design, Beam distance 300, 400 and 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Start/Restart disable , Degree of protection IP67, 7-segment diagnostic display, Operating reserve indication, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 relay outputs, force-guided NO-contactfa
1-10/76Itens por Página:
Não encontrou nenhum resultado?
Dica: Digite o caractere * antes do termo a ser pesquisado, modifique sua pesquisa, verifique os termos ou entre em contato conosco.