Serviceline Industriële Sensoren
Serviceline Explosiebeveiliging

Distance sensor OMD10M-R200-UEP-IO-V1-L

OMD10M-R200-UEP-IO-V1-L
  • Medium design with versatile mounting options
  • Space-saving distance sensors in small standardized design
  • Measuring method PRT (Pulse Ranging Technology)
  • IO-Link interface for service and process data
  • Red laser light, laser class 1
  • Analog output 0 ... 10 V

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

De complete datasheet als PDF downloaden:


Technische gegevens  OMD10M-R200-UEP-IO-V1-L

Productbeschrijving
Universal distance sensor, measurement to object, IO-Link interface, measuring method PRT, measuring range up to 10 m, red laser light, laser class 1, push-pull output, analog output, M12 plug
General specifications
Measuring range0.03 ... 10 m
Reference targetstandard white 90 %, 100 mm x 100 mm
Light sourcelaser diode
Light typemodulated visible red light
Laser nominal ratings
NoteLASER LIGHT , DO NOT STARE INTO BEAM
Laser class1
Wave length660 nm
Beam divergence2 mrad
Pulse length4 ns
Repetition rate300 kHz
max. pulse energy< 1.3 nJ
Measuring methodPulse Ranging Technology (PRT)
Max. Motion velocity10 m/s
Diameter of the light spot< 20 mm at 10 m
Ambient light limit50000 Lux @ 2.5m standard white 90 %
10000 Lux @ 2.5m black 6 %
Resolution1 mm
Temperature influence< 0.25 mm/K
Functional safety related parameters
MTTFd> 300 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED green:
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
Function indicatorLED yellow:
constantly on - switch output active
constantly off - switch output inactive
Teach-in indicatorTeach-In : LED yellow/green; equiphase flashing; 2,5 Hz
Teach Error:LED green/yellow non equiphase flashing; 8.0 Hz
Control elementsTeach-In key
Control elements5-step rotary switch for operating modes selection
Electrical specifications
Operating voltage18 ... 30 V DC
Ripple10 % within the supply tolerance
No-load supply current< 25 mA at 24 V Operating voltage
Protection classIII
Time delay before availability< 900 ms
Interface
Interface typeIO-Link ( via C/Q = pin 4 )
IO-Link revision1.1
Device profileIdentification and Diagnosis - I&D
Smart Sensor - SSP 4.2.1
Process dataInput 6 Byte
- measurement value 4 Byte
- scaling factor 8 Bit
- signal quality 2 Bit
- switching signal 1 1 Bit
- switching signal 2 1 Bit
- diagnosis signals n Bit
- additional signals n Bit
Output 2 Bit
- sensor control function 1 Bit
- evaluation freeze 1 Bit
Vendor ID1 (0x0001)
Device ID1121027 (0x111B03)
Transfer rateCOM2 (38.4 kBit/s)
Min. cycle time4 ms
SIO mode supportyes
Output
Switching typeThe default setting is:
C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link
U—Pin2: analog output 0 ... 10 V
Signal output1 push-pull output , 1 analog output , reverse polarity protected , overvoltage protected
Switching voltagemax. 30 V DC
Switching currentmax. 100 mA , resistive load
Usage categoryDC-12 and DC-13
Voltage drop≤ 1.5 V DC
Response time3 ms
Analog output
Output type1 voltage output: 0 ... 10 V
Load resistor> 1 kΩ voltage output ; ≤ 470 Ω current output
Recovery time2 ms
Conformity
Communication interfaceIEC 61131-9 / IO-Link V1.1.3
Product standardEN 61000-6-2, EN 61000-6-3
Laser safetyEN 60825-1:2014
Measurement accuracy
Warm up time5 min
Measured value output1 ms
Average data age3 ms (default), 6 ms , 12 ms , 25 ms , 50 ms , 100 ms , adjustable
Absolute accuracytyp. ± 20 mm (including influence of temperature)
Repeat accuracy< 3 mm
Approvals and certificates
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
CCC approvalCCC approval / marking not required for products rated ≤36 V
FDA approvalIEC 60825-1:2014 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
Ambient conditions
Ambient temperature-30 ... 60 °C (-22 ... 140 °F)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Degree of protectionIP67 / IP69 / IP69K
Connection4-pin, M12 x 1 connector, 90° rotatable
Material
HousingPC (Polycarbonate)
Optical facePMMA
Massapprox. 37 g
Dimensions
Height50.6 mm
Width15 mm
Depth41.7 mm
Factory settings
Switching output 1Q1: switching signal high-active , Window mode 6000 ... 9000 mm
Switching output 2Q2: Window mode ( rising ramp ) 200 ... 5000 mm

Classifications

SystemClasscode
ECLASS 13.027270916
ECLASS 12.027270916
ECLASS 11.027270801
ECLASS 10.0.127270801
ECLASS 9.027270801
ECLASS 8.027270801
ECLASS 5.127270801
ETIM 9.0EC001825
ETIM 8.0EC001825
ETIM 7.0EC001825
ETIM 6.0EC001825
ETIM 5.0EC001825
UNSPSC 12.141111613

Details: OMD10M-R200-UEP-IO-V1-L

Informative Literature: OMD10M-R200-UEP-IO-V1-L

Taalkeuze:
LiteratureTaalBestandstypeBestandsgrootte
Product information R10x and R20x Series Standard Housings - All Sensing ModesENGPDF2583 KB
Application Report - Compact Design and Precise Distance Measurement up to 60 mENGPDF332 KB

Product Documentation: OMD10M-R200-UEP-IO-V1-L

Taalkeuze:
Product informationTaalBestandstypeBestandsgrootte
Installation and user instructions for offline parameterization of IO-Link sensorsENGPDF1788 KB
Parameter Information
IO-Link parameter documentation OMD10M-R200-UEP-IO* seriesENGPDF437 KB

Design / Simulation: OMD10M-R200-UEP-IO-V1-L

Taalkeuze:
CADTaalBestandstypeBestandsgrootte
CAD 3-D / CAD 3-DALLSTP1499 KB

Approvals: OMD10M-R200-UEP-IO-V1-L

Taalkeuze:
CertificatesCertificaatnummerTaalBestandstypeBestandsgrootte
Canada USA UL Ordinary LocationUL-US-L87056-11-41301991-3 / UL-CA-L87056-31-41301991-3ALLPDF1806 KB
Declaration of Conformity
EU Declaration of Conformity (P+F)TDOC-7485_HOLHOLPDF219 KB
UK Declaration of Conformity (P+F)TDOC-7486_ENGENGPDF195 KB

Software: OMD10M-R200-UEP-IO-V1-L

Taalkeuze:
Device Description Files/DriversVrijgave-informatieBestandstypeBestandsgrootte
IODD for OMD10M-R200-UEP-L series / IODD für OMD10M-R200-UEP-L SerieV1.00.001 / 2023-10-30ZIP274 KB
DTM / DTMZIP16922 KB
Software Tools
IO-Link Offline Parameterization Tool / IO-Link Offline-ParametriertoolV1.00.006 / 2022-07-10ZIP96138 KB

Aanverwante producten: OMD10M-R200-UEP-IO-V1-L

Accessories

Female connector M12 straight A-coded 4-pin, for cable diameter 6 - 8 mm, field-attachablefa

Female connector M12 angled A-coded 4-pin, for cable diameter 6 - 8 mm, field-attachablefa

Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable greyfa

Female cordset single-ended M12 angled A-coded, 4-pin, PUR cable greyfa
M12 protective cap set (connector + socket) for series LS610 / LS611fa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Download from Pepperl+Fuchs websitepa
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa

Ontdek de SmartRunner-laserprofielsensoren met een unieke combinatie van lichtsectietechnologie en een 2D-vision sensor met ingebouwde LED’s …

De R2000 biedt betrouwbare en uiterst nauwkeurige meetresultaten, met een aaneensluitend 360° zicht rondom...

Meten in 3D of op hoge snelheid: De R2300-serie biedt de geschikte LiDAR-sensor voor elke uitdaging. Meer informatie over de voordelen, de technologie en de toepassingsmogelijkheden...

De optische sensoren van de R10x- en R20x-series

Voor het eerst is er een consistente reeks sensoroplossingen beschikbaar die optische functieprincipes en innovatieve technologieën in identieke behuizingen verenigt. Gebruikers genieten van een uniform bedieningsconcept voor het volledige portfolio. Ontdek de R100-, R101-, R103-, R200- en R201-series...

De afstandssensoren met geavanceerde technologieën bieden de hoogste mate van nauwkeurigheid en betrouwbaarheid ...