Up to 50,000 ppr, Extended temperature range, Industrial standard housing ∅58 mm, Servo or clamping flange, 10 V ... 30 V with RS 422 interface, Output type: RS 422, incrementalfa
Industrial standard housing ∅58 mm, ATEX approval, Up to 5000 ppr, Servo or clamping flange, 10 V ... 30 V with short-circuit proof push-pull output, Enclosure type: 58 mm, Type of shaft: Solid shaft, Interface: push-pull, incremental, Application: Ex protection, Detection type: photoelectric sampling, Output type: push-pull, incrementalfa
Industrial standard housing ∅58 mm, ATEX approval, Up to 5000 ppr, Servo or clamping flange, 5 V with RS-422 interface, Enclosure type: 58 mm, Type of shaft: Solid shaft, Interface: RS-422, Application: Ex protection, Detection type: photoelectric sampling, Output type: RS 422, incrementalfa
Industrial standard housing ∅58 mm, ATEX approval, Up to 5000 ppr, Servo or clamping flange, 10 V ... 30 V with RS 422 interface, Enclosure type: 58 mm, Type of shaft: Solid shaft, Interface: RS-422, Application: Ex protection, Detection type: photoelectric sampling, Output type: RS 422, incrementalfa
Industrial standard housing ∅58 mm, 1024 or 2048 signal periods, Servo or clamping flange, Temperature compensated, interpolateable voltage signals, Output type: sine / cosinefa
Various enclosure materials available, Ex d, Ex e and Ex tD certified, Safe protection for various instruments, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66 / IP67pa
Power supply for IDM-Z1-* handheld readers and base station, AC and DC power supplies for IDM-Z1-* handheld readers and base station, Enable operation in Zone 1/21, Sturdy aluminum housingpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Niet beschikbaar voor verkoop: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Niet beschikbaar voor verkoop: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Niet beschikbaar voor verkoop: Diffuse sensor with measurement core technology, large housing design, background suppression and 3 more adjustable operating modes, IO-Link interface, 800 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable, Cost-optimized series for standard tasks, Sensing-by-ranging functionality, IO-Link interface for service and process data, PowerBeam transmitter LED, Large adjustment range can be precisely definedfa
Het ultrasone USi-veiligheidssysteem verricht pionierswerk op het gebied van veiligheidstoepassingen—zowel in stoffige, industriële fabrieksomgevingen als buiten Leer meer over het ultrasoon USi-veiligheidssysteem ... . Het Ultrasone USi®-Safety-Sensorsysteem Conform Cat. 3/ PL d Ultrasone technologie voor veiligheid in alle omgevingen Het ultrasone USi-veiligheidssysteem verricht pionierswerk op het gebied van veiligheidstoepassingen—zowel in stoffige, industriële ...
Bij autonoom transport moeten de zones vóór en naast de AGV worden gemonitord om botsingen met werknemers en obstakels te voorkomen De ultrasone USi-sensorsystemen detecteren op betrouwbare wijze alle obstakels in de vooraf ingestelde veilige zones ... weersomstandigheden en moet betrouwbaar blijven functioneren bij vuil, vocht, mist of andere storingen. De bescherming moet voldoen aan de ISO 13849-1-norm, categorie 3/ PL d . De Oplossing USi-safety, het ultrasoon veiligheidssysteem Verschillende USi ...
The German company Wohlenberg Buchbindesysteme (Wohlenberg Bookbinding Systems) is using vision sensors from Pepperl+Fuchs in collating machines and adhesive binders for the detection of incorrect sheets ... . Put into practice The German company Wohlenberg Buchbindesysteme (Wohlenberg Bookbinding Systems) is using Pepperl+Fuchs’ vision sensors in collating machines and adhesive binders to detect incorrect sheets . The sensor’s camera, lighting and ...
100% product traceability in the production process is a requirement Marking small products can be difficult Data Matrix Barcodes are an ideal solution Using the Data Matrix ECC 200 codes ensures reliable product tracing and quality assurance ... by using the Data Matrix ECC 200 . This 2D-code is used to encode characters in a very small space. The limits are only set by the respective printing technology employed. The label is a tried and trusted means of identification. Modern methods ...
The Tab-Ex 04 Pro from Pepperl+Fuchs is the world's first 5G Android™ tablet with a 10-inch display Learn more about the next-generation mobility device for use in Zone 2/22 and Division 2 hazardous ... . This provides the necessary computing power to fully benefit from the higher data transmission speed. In addition to the 128 GB internal memory, the storage capacity can be expanded from 512 GB to 1 TB using an external microSD card. The device has been ...
1-5/46Artikelen per pagina:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.