Inductive sensor NJ10-22-N

NJ10-22-N
  • 10 mm non-flush
  • Usable up to SIL 2 acc. to IEC 61508


NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below:

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Technische gegevens  NJ10-22-N

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance10 mm
Installationnon-flush
Assured operating distance0 ... 8.1 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.3
Reduction factor r304 0.85
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 ... 2000 Hz
Hysteresis1 ... 9 typ. 5 %
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected≤ 1 mA
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
MTTFd4560 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level GbIECEx PTB 11.0037X
Equipment protection level DaIECEx PTB 11.0037X
Equipment protection level MbIECEx PTB 11.0037X
ATEX approval
Equipment protection level GbPTB 00 ATEX 2048 X
Equipment protection level DaPTB 00 ATEX 2048 X
UL approvalcULus Listed, General Purpose
CCC approval
Hazardous Location2020322315002255
NEPSI approval
NEPSI certificateGYJ16.1393X
CML approvalon request
ANZEx18.3018X
KCC approval
Hazardous Location19-AV4BO-0227
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Mechanical specifications
Connection typecable
Housing materialPBT
Sensing facePBT
Degree of protectionIP68
Cable
Cable diameter6 mm ± 0.2 mm
Bending radius> 10 x cable diameter
MaterialPVC
Core cross section0.75 mm2
Length2 m
Dimensions
Length35 mm
Diameter22 mm
General information
Use in the hazardous areasee instruction manuals

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: NJ10-22-N

Datasheet: NJ10-22-N

DatasheetBestandstypeBestandsgrootte
Datasheet NJ10-22-NPDF464 KB
Datasheet NJ10-22-NPDF461 KB
Fiche de données NJ10-22-NPDF461 KB
Datenblatt NJ10-22-NPDF461 KB
Scheda tecnica NJ10-22-NPDF460 KB
Datasheet NJ10-22-NPDF466 KB
Folha de dados NJ10-22-NPDF462 KB
Hoja de datos NJ10-22-NPDF461 KB
Datasheet NJ10-22-NPDF473 KB

Documents: NJ10-22-N

Instruction manualsBestandstypeBestandsgrootte
ИнструкцииPDF185 KB
Návod k poużitíPDF177 KB
Instruktions manualPDF176 KB
Instruction manualPDF177 KB
KasutusjuhendPDF171 KB
KäyttöohjePDF171 KB
Manuel d'instructionsPDF180 KB
BetriebsanleitungPDF178 KB
Οδηγίες χρήσηςPDF187 KB
HandleidingPDF177 KB
Instruction manual / BetriebsanleitungPDF175 KB
Használati útmutatóPDF180 KB
Manuale di istruzioniPDF178 KB
Lietošanas pamācībaPDF176 KB
Instrukciju vadovasPDF178 KB
Instrukcja obsługiPDF178 KB
Manual de instruçõesPDF180 KB
Manual de utilizarePDF180 KB
Návod na poużitiePDF178 KB
Navodila za uporaboPDF175 KB
Manual de instruccionesPDF180 KB
ManualPDF175 KB
Technical information
Installation conditionsPDF1054 KB
EinbaubedingungenPDF1060 KB

CAD+CAE: NJ10-22-N

CADBestandstypeBestandsgrootte
CAD 3-D / CAD 3-DSTP54 KB
CAD Portal / CAD PortalLINK---
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
EPLAN macro EDZ / EPLAN Makro EDZEDZ59 KB

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont met Active Shielding Technology

De inductieve VariKont-sensoren met Active Shielding Technology bieden grote schakelafstanden, ongeacht de montageomstandigheden of omgevingsinvloeden. Haal voordeel uit vereenvoudigd installatieontwerp en beperkte kosten!

Inductive Safety Sensors SIL 2 PL d

Gezien de SIL 2-/PL d-geclassificeerde inductieve veiligheidssensoren geen dode zone hebben, kan de gegevensoverdracht worden gewaarborgd zonder handhaving van een minimumafstand tussen sensor en doel. Ontdek onze geoptimaliseerde portfolio voor zware industriële omgevingen.