Print mark contrast sensor, 11 mm detection range, RGB light parallel with the longitudinal direction of the housing, light/dark ON, external Teach-In, 2 push-pull outputs, M12 plug, Diffuse mode sensor for recording any print mark, Teach-in, static and dynamic, 50 µs response time, suitable for extremely rapid scanning processes, 3 emitter colors: green, red and bluefa
Photoelectric slot sensor, zinc pressure diecast housing, 30 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
Photoelectric slot sensor, zinc pressure diecast housing, 80 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa
Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa
Indisponível para compra: 2-channel, DC version, positive polarity, Working voltage 26.5 V/6.5 V at 10 µA, Series resistance max. 250 Ω/64 Ω, Fuse rating 80 mA, DIN rail mounting, High power version, Asymmetrical version, Internal measuring resistor, Type: DC version, positive polaritypa
Indisponível para compra: 1-channel, DC version, negative polarity, Working voltage 0.9 V at 1 µA, Series resistance max. 18.18 Ω, Fuse rating 250 mA, DIN rail mounting, Type: DC version, negative polaritypa
Indisponível para compra: 1-channel, DC version, negative polarity, Working voltage 13 V at 10 µA, Series resistance max. 107 Ω, Fuse rating 100 mA, DIN rail mounting, Type: DC version, negative polaritypa
Indisponível para compra: 1-channel, DC version, negative polarity, Working voltage 13 V at 10 µA, Series resistance max. 1025 Ω, Fuse rating 100 mA, DIN rail mounting, Increased nominal resistance 1 kΩ, Type: DC version, negative polaritypa
Indisponível para compra: 1-channel, DC version, negative polarity, Working voltage 13 V at 10 µA, Series resistance max. 121 Ω, Fuse rating 63 mA, DIN rail mounting, Replaceable back-up fuse, Type: DC version, negative polaritypa
Indisponível para compra: 1-channel, DC version, negative polarity, Working voltage 26.5 V at 10 µA, Series resistance max. 342 Ω + 2 V, Fuse rating 50 mA, DIN rail mounting, Current limiting, Type: DC version, negative polaritypa
Indisponível para compra: 1-channel, DC version, negative polarity, Working voltage 26.5 V at 10 µA, Series resistance max. 341 Ω, Fuse rating 50 mA, DIN rail mounting, Replaceable back-up fuse, Type: DC version, negative polaritypa
Indisponível para compra: 2-channel, DC version, negative polarity, Working voltage 0.9 V at 1 µA, Series resistance max. 18.18 Ω, Fuse rating 250 mA, DIN rail mounting, Type: DC version, negative polaritypa
Indisponível para compra: 2-channel, DC version, negative polarity, Working voltage 26.5 V at 10 µA, Series resistance max. 327 Ω, Fuse rating 50 mA, DIN rail mounting, Type: DC version, negative polaritypa
O sensorultrassônicoWILSENPepperl+Fuchsbaseado em LoRaWAN é uma soluçãorobusta para monitoramento de nível de enchimento e medição de distância ... sensata e adequada à aplicação e, por outro, a alcançar a maiorduraçãopossível da bateria. RSSInfoServiceStayinformedatanytimewhen a newfirmwareupdate for theWILSENsensorsisreleased: WithourRSSfeed , youwillreceiveanemail ...
A Pepperl+Fuchsoferece uma solução de sistemaIO-Link de ponta a ponta, que inclui uma variedade de sensoresIO-Link e infraestrutura ... ) As sériesmestreIO-LinkICE2 (EtherNet/IP) e ICE3 (PROFINET) com interfaceOPCUApermitem uma troca de informaçõesindependente de plataforma entre fornecedores em sistemashíbridos e baseados em nuvem. MestresIO-Link para aplicaçõesbaseadas em PLC (ICE1 ...
Visite o "Hub de segurançafuncional" da Pepperl+Fuchs, onde você encontrarádispositivosavaliadosquanto à segurança para aplicações de automação de fábricas e também poderá acessarferramentas e folhetosúteis ... de leitura2-D e fita de códigoDataMatrixmulticolorida . O firmwareintegradoverifica a plausibilidade dos valores de posiçãoXusandoLEDsvermelhos e azuis e, em seguida, os retransmite para o PLC de segurança. Módulo de interface AS CB10 ...
Acesse a visãogeral do amploportfólio de sistemas de HMI da Pepperl+Fuchs para indústrias de processamento ... de 4K a 60Hz. BPC3200 O BoxPCSeries3200oferece aos usuáriosgrandeflexibilidade. Os PCsBoxindustriaisvêm com processadorIntelCeleron e i5incorporado (KabyLake) de sétimageração. Eles também aceitam a mais recentetecnologia de armazenamento ...
Os sensores de radarFMCWindustriais da Pepperl+Fuchsapresentam um altoalcance de leitura e são ideais para integração em máquinasmóveis ... Dependingontheapplication, theindustrialFMCWradarsensorsfromPepperl+Fuchscanbeoperatedinthreedifferentmeasurementmodes. TherespectivemodeisconvenientlysetupviaPACTwarewithouttheneed for additionalparameterizationtools. In ...
1-5/919Itens por Página:
Não encontrou nenhum resultado?
Dica: Digite o caractere * antes do termo a ser pesquisado, modifique sua pesquisa, verifique os termos ou entre em contato conosco.