Print mark contrast sensor, 11 mm detection range, RGB light parallel with the longitudinal direction of the housing, light/dark ON, external Teach-In, 2 push-pull outputs, M12 plug, Diffuse mode sensor for recording any print mark, Teach-in, static and dynamic, 50 µs response time, suitable for extremely rapid scanning processes, 3 emitter colors: green, red and bluefa
Photoelectric slot sensor, zinc pressure diecast housing, 30 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
Photoelectric slot sensor, zinc pressure diecast housing, 80 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: resistance thermometer, Signal: Resistancepa
1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, HART communication, Safety Integrity Level (SIL): SIL 3, Rated voltage: 0 ... 24 V DC , loop powered, Signal: 1 x 1 ... 20 mA, Signal [2]: 1 x HART, Device: 1 x fire alarm, Signal: 1 x 1 ... 20 mApa
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, HART communication, Trip relay, Safety Integrity Level (SIL): SIL 2pa
1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART-IP and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Signal: 2 x 4 ... 20 mA, Line fault detectionpa
2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART-IP and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Transfer direction: to the field, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Signal: 2 x 4 ... 20 mA, Line fault detectionpa
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x Transistor (passive)pa
Indisponível para compra: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Indisponível para compra: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Indisponível para compra: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Indisponível para compra: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Indisponível para compra: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Indisponível para compra: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Indisponível para compra: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Indisponível para compra: 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 65 mA at 9.8 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: 20 ... 35 V DC , loop powered, Type: field device supply, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarm, Current: ≤ 65 mA, Voltage: ≥ 9.8 Vpa
Indisponível para compra: 2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: logic input, Field device: 2 x Valve, Field device [2]: 2 x audible alarm, Field device [3]: 2 x visual alarm, Current: ≤ 45 mA, Voltage: ≥ 11.7 Vpa
Indisponível para compra: Universal thru-beam sensor, large housing design, 60 m detection range, infrared light, light/dark on, detection range adjuster, DC version, 2 push-pull outputs, adjustable timer functions, M12 plug, Cost-optimized series for standard tasks in a special design, Compact design, Wide range of mounting options thanks to cubic housing design with M30 thread, 360° high visibility LEDs, Programmable ON-delay, OFF-delay, and One-shot timersfa
Krifft & Zipsner GmbH supplies printing machines with automated logistics systems at delivery and in feed All operator-accessible points on the machine are monitored with safety light barriers and li ... system components. Configurable without PC Another important reason why the logistics specialist Krifft & Zipsner decided to use Safebox is that it can be commissioned and maintained without using a PC. No programming, linking of inputs and outputs ...
Pepperl+Fuchs' rotary encoders are used to slow and control the speed of a process, resulting in increased efficiency ... classic safety considerations that, when properly implemented, lead to productivity increases and cost optimization. Architecture also leads to savings potential by reducing external safety components. This is implemented using a drive-based safety concept ...
Pepperl+Fuchs' F61 industrial RFID reading head forms the basis for a track switch reading point on a conveyor system ... and transports goods to their destination. Featuring an extremely slim design, the F61 reading head is ideal for integrating in machines or installing in locations with limited space . The benefits of using industrial RFID in conveyor systems ...
Signal conditioners guarantee dependable conversion and transmission of signals in the vulcanization process during tire manufacturing Learn more about the application ... this module is particularly robust in harsh ambient conditions, especially at high ambient temperatures. When using a normal thermometer, the universal temperature converter KFD2-UT2-2 is also suitable. There is an additional advantage to this module ...
Elevadores de tesoura são usados em várias etapas da produção, da constr da carroceria à mont final Os sens de segurança indutivos são ideais para detecção confiável da posição final dos elev tes ... parte do corpo entre as peças do sistema, o trabalho nos elevadores de tesoura só pode ser realizado se os elevadores estiverem travados no lugar. A peça na mesa só pode ser liberada para usinagem quando essa posição final é sinalizada. A Solução Sensor ...
Ver Todos: Nossos sensores ultrassônicos apresentam a solução ideal para a medição de distância e posição sem contato em todas as áreas industriais Entre em contato conosco para esclarecer suas dúvid ... , os nossos acessórios prolongam seguramente a vida útil dos sensores. NOVIDADE: Proteção confiável de acordo com a Categoria 3 PL d Sistema de sensor ultrassônico de segurança USI O Sistema de sensor ultrassônico de segurança USI está abrindo novos caminhos ...
Pepperl+Fuchs' GOVAN provides you with sturdy, fully certified equipment for switching and monitoring in explosion-hazardous areas ... their own foundries. Using the highest manufacturing standards ensures that we are always able to meet our stringent quality, safety, and reliability standards. Choose Your GOVAN® Product Range If you are already familiar with GOVAN® products, and are ...
Pepperl+Fuchs' fieldbus handheld FDH-1 has comprehensive monitoring and diagnostics ... . Its comprehensive monitoring and diagnostics enables you to set up a reliable, top quality fieldbus physical layer . Check out five reasons on why using the FDH-1 makes fieldbus installation and maintenance as simple as possible. 1. Familiarity: Take ...
Pepperl+Fuchs' PXV absolute positioning system sets new benchmarks for reliability, noise immunity, and handling Discover the most reliable positioning system on the market ... the exact position in relation to the camera's center. Using Data Matrix codes as information carriers allows data to be redundantly mapped . Due to these multiple redundancies, the PXV is extremely resistant to interference. Even if one or more Data ...
Pepperl+Fuchs offers the inductive positioning systems PMI F90 and PMI F112 that feature comprehensive functions, paving the way for modern industry 40 applications ... information . High flexibility. Broad functionality. Diverse applications. Inductive positioning systems operate contact-free using an inductive sensor and a damping element . There is no need for a special target —a steel target or a machine part itself can ...
51-60/75Itens por Página:
Não encontrou nenhum resultado?
Dica: Digite o caractere * antes do termo a ser pesquisado, modifique sua pesquisa, verifique os termos ou entre em contato conosco.