458 mm x 382 mm x 215 mm, 316L Stainless Steel, Ex e, Ex ia and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Straight Edge Sealing, No Gland Plate, Customizable configuration of terminals, cable entries and cable gland types as per specification, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa
480 mm x 480 mm x 215 mm, 316L Stainless Steel, Ex e, Ex ia and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Straight Edge Sealing, No Gland Plate, Customizable configuration of terminals, cable entries and cable gland types as per specification, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa
500 mm x 350 mm x 215 mm, 316L Stainless Steel, Ex e, Ex ia and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Straight Edge Sealing, No Gland Plate, Customizable configuration of terminals, cable entries and cable gland types as per specification, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa
620 mm x 450 mm x 215 mm, 316L Stainless Steel, Ex e, Ex ia and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Straight Edge Sealing, No Gland Plate, Customizable configuration of terminals, cable entries and cable gland types as per specification, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa
762 mm x 508 mm x 215 mm, 316L Stainless Steel, Ex e, Ex ia and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Straight Edge Sealing, No Gland Plate, Customizable configuration of terminals, cable entries and cable gland types as per specification, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa
Aankoop niet mogelijk: For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Non-hazardous area: screw terminals, black, Number of modules: 8, Number of channels per module: 2 , 4, Signal type: Universal, Manufacturer: Universal, Control system type: Universalpa
Aankoop niet mogelijk: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Aankoop niet mogelijk: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Aankoop niet mogelijk: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Aankoop niet mogelijk: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Aankoop niet mogelijk: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Aankoop niet mogelijk: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Aankoop niet mogelijk: Surge protection for 2 supply lines, Type 3 acc. to EN 61643-11, Nominal voltage 120 V AC, Pre-wired unit, Operating state and fault indication of every protected line, Fault indication output, DIN rail mountable, Device type: type 3 acc. to EN 61643-11:2013 class III acc. to IEC 61643-1:2011, Number of protected supply lines: 2pa
Het nieuwe, vooruitstrevendeBebcoEPS® purge- en overdruksysteem werd ontwikkeld voor ClassI- of II/Div3- en Zone2/22-omgevingen Als manueel of automatischsysteem, beschikt het over alle vereistekenmerken voor een betrouwbarebescherming van de Ex-omgeving ... purgeandpressurizationsystem is asolutionthatenablesconventionalelectricalequipmenttobeused in hazardousareas. Devicesthatrequireprotectionareinstalled in anenclosurewithapressurethat is higherthanthat of thesurrounding ...
Een ontwikkelingsteam van zeven bedrijvenwerktmomenteel aan een nieuwegeneratie van AS-interface die prestaties tot een volledignieuwniveau zal optrekkenLeer meer over de kostenefficiëntiecommunicatietechnologie voor sensoren en actuators ... . 2EMC-bestendig Het robuusteAS-i-systeem is volledigbestand tegen elektromagnetischestoringen en vereist geen dureafscherming. 3VrijheidquanetwerktopologieGezienASi-5 geen dureschakelaars of actieveverdelersvereist, kunnen apparaten ...
TheNeoceptionAssetTracker is acloud-basedassetmanagementsystemandconsists of RFIDtechnologyfromPepperl+FuchscombinedwithagatewayandtheinnovativesoftwareservicesfromNeoception ... number of timesanassethascycledthroughtheprocess. Youwillreceivecustomizedalertsoncethepreconfiguredthresholdvaluehasbeenreachedsoinspectionandmaintenancecanbescheduledontime. Yourbenefit: youcanbuyNeoceptionsoftwareasa ...
De nieuwe5500-serie is de meest recentetoevoeging aan Pepperl+Fuchs' BebcoEPSassortimentbeproefdepurge- en overdruksystemen ... ExternemontageInternemontageExternemontageInternemontage5500SeriesonYouTube In thisYouTubevideo, ourProductPortfolioManagerChrisRomanogivesyouanintroductiontothe5500series. Heexplainsthedifferentmountingconcepts, technical ...
De ENA58IL-seriemagnetische, roterendeencoders maakt indruk met hogeresoluties en een nauwkeurigheid van <0,1° Ontdek de nieuwenorm voor roterendeencoders! ... wijze de positie en snelheid van de robotarm en zorgen ze voor een vlotlopendeprocesstroom. De uiterstrobuustemagnetischeencoderserie42H is berekend voor zwaarwerk en zorgtzelfs bij hevigeschokken of trillingen voor een nauwkeurigepositionering ...
1-5/1152Items per pagina:
Niet gevonden ?
Hint: plaats een * voor uw zoekwoord, verander uw zoekterm, controleer uw zoekterm op spellingsfouten, of neem contact met ons op.