Adapter Set CAN/USB-Configuration-Kit

CAN/USB-Configuration-Kit
  • Plug & Play connection of CAN bus network components
  • Transmission rate CAN bus up to 1 MBit/s
  • Integrated, switchable bus terminal resistor
  • Degree of protection IP20
  • Galvanic isolation

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

De complete datasheet als PDF downloaden:


Technische gegevens  CAN/USB-Configuration-Kit

Productbeschrijving
CAN/USB configuration kit containing CAN/USB converter, power supply and adapter/connection cables
Electrical specifications
Operating voltage5 V via USB
Operating current500 mA via USB
Galvanic isolation1000 V DC / 1 sec
500 V AC / 1 min
Interface
Interface typeHi-Speed USB 2.0
CAN 2.0 A/B
Data transfer rateCAN baud rate: 10 kbit/s ... 1 Mbit/s
System requirements
Hardware requirementsPC
Operating systemMicrosoft Windows 10 (32 and 64 Bit)

Classifications

SystemClasscode
ECLASS 13.027060390
ECLASS 12.027060390
ECLASS 11.027060390
ECLASS 10.0.127060390
ECLASS 9.027060390
ECLASS 8.027060390
ECLASS 5.127279201
ETIM 9.0EC000310
ETIM 8.0EC000310
ETIM 7.0EC000310
ETIM 6.0EC000310
ETIM 5.0EC002585
UNSPSC 12.131251501

Details: CAN/USB-Configuration-Kit

Product Documentation: CAN/USB-Configuration-Kit

Taalkeuze:
Brief InstructionsTaalBestandstypeBestandsgrootte
Brief instructionsENGPDF66 KB

Approvals: CAN/USB-Configuration-Kit

Taalkeuze:
Declaration of ConformityCertificaatnummerTaalBestandstypeBestandsgrootte
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-6858ALLPDF116 KB

Software: CAN/USB-Configuration-Kit

Taalkeuze:
Software ToolsVrijgave-informatieBestandstypeBestandsgrootte
CANopen Parameterization Tool / CANopen ParametriertoolV1.00.001 / 2022-07-05ZIP149071 KB

Aanverwante producten: CAN/USB-Configuration-Kit

Accessory of

Radar sensor for distance and velocity measuring up to 25 m sensing range, with M12 connector, CANopen interface, Sensing range up to 25 m, Degree of protection IP68 / IP69fa
Inertial measurement unit for inclination, acceleration and rotation rate measurement in 3-axis each, Dynamic inclination measurement despite external acceleration, Adjustable ranges for compensation of external accelerations, disturbances, Adjustable thresholds for detection of measured value overruns, Measurement of inclination, acceleration and rotation rate in 3 axis each, CAN bus with CANopenfa
Single head system, CANopen interface, E1-Type approval, High EMC resistance, Series: -L2M, Interface type: CAN, Communication protocol: CANopen, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, UN/ECE Regulation No. 10 (E1): Type-approval number: 10R-069608, Connection type: Connector plug, Housing: PA-GF35, Threading: M12fa
Single head system, CANopen interface, E1-Type approval, High EMC resistance, Series: -L2M, Interface type: CAN, Communication protocol: CANopen, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, UN/ECE Regulation No. 10 (E1): Type-approval number: 10R-069608, Connection type: Connector plug, Housing: PA-GF35, Threading: M12fa
Single head system, CANopen interface, E1-Type approval, High EMC resistance, Series: -L2M, Interface type: CAN, Communication protocol: CANopen, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, UN/ECE Regulation No. 10 (E1): Type-approval number: 10R-069608, Connection type: Connector plug, Housing: PA-GF35, Threading: M12fa
Inertial measurement unit for inclination, acceleration and rotation rate measurement in 3-axis each, Dynamic inclination measurement despite external acceleration, Adjustable ranges for compensation of external accelerations, disturbances, Adjustable thresholds for detection of measured value overruns, Measurement of inclination, acceleration and rotation rate in 3 axis each, CAN bus with SAE J1939 protocolfa
Radar sensor for distance and velocity measuring up to 25 m sensing range, with AMP connector, CANopen interface, Sensing range up to 25 m, Degree of protection IP68 / IP69fa
Radar sensor for distance and velocity measuring up to 25 m sensing range, with DEUTSCH connector, CANopen interface, Sensing range up to 25 m, Degree of protection IP68 / IP69fa
Radar sensor for distance and velocity measuring up to 25 m sensing range, with 2m cable, CANopen interface, Sensing range up to 25 m, Degree of protection IP68 / IP69fa
Kit component
DeviceNet/CANOpen bus cable M12 socket straight to M12 socket straight A-coded, 5-pin, PUR cable violet, shielded, UL approved, drag chain suitable, salt water resistantfa
Adapter Sub-D straight 9-pin to M12 plug / M12 socket straight A-coded 4-pinfa
Adapter cable M12 plug straight A-coded 4-pin to DC socket straight 2-pin, PUR cable black, drag chain suitable, torsion resistantfa
24 V DC power supplyfa
Gratis Download: Whitepaper over TCP-gebaseerde communicatieprotocollen (pdf)

Dit gratis whitepaper vergelijkt de verschillende TCPgebaseerde -communicatieprotocollen (AMQP, OPC UA, MQTT, REST API) die zich overal hebben ingeburgerd en als sleuteltechnologieën voor IIoT en Industrie 4.0 worden beschouwd. Download uw gratis exemplaar!

As-interface productportfolio

Ontdek ons volledig As-interface productportfolio.