Print mark contrast sensor, 11 mm detection range, RGB light parallel with the longitudinal direction of the housing, light/dark ON, external Teach-In, 2 push-pull outputs, M12 plug, Diffuse mode sensor for recording any print mark, Teach-in, static and dynamic, 50 µs response time, suitable for extremely rapid scanning processes, 3 emitter colors: green, red and bluefa
Photoelectric slot sensor, zinc pressure diecast housing, 30 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
Photoelectric slot sensor, zinc pressure diecast housing, 80 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: resistance thermometer, Signal: Resistancepa
1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, HART communication, Safety Integrity Level (SIL): SIL 3, Rated voltage: 0 ... 24 V DC , loop powered, Signal: 1 x 1 ... 20 mA, Signal [2]: 1 x HART, Device: 1 x fire alarm, Signal: 1 x 1 ... 20 mApa
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, HART communication, Trip relay, Safety Integrity Level (SIL): SIL 2pa
1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART-IP and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Signal: 2 x 4 ... 20 mA, Line fault detectionpa
2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART-IP and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Transfer direction: to the field, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Signal: 2 x 4 ... 20 mA, Line fault detectionpa
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x Transistor (passive)pa
Indisponível para compra: Low-profile, high resolution light grid for monitoring locking edges on elevators and accesses, Thru-beam light grid with integrated controller, In accord with EN81-70 and EN12015/16, Dense monitoring field with up to 135 beams ensures that small objects are detected, Automatic beam crossing and beam suppression, Operating voltage: 11 ... 30 V DC, UL approval: cULus Listed, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection: M8 x 1 connector, 4-pin, Housing: Aluminumfa
Indisponível para compra: Optical data coupler, Compact, flat aluminum housing, 3 interfaces in a device can be selected via DIP switches, Infrared light, Mating connector with protective cover included deliveryfa
Indisponível para compra: Optical data coupler, Compact, flat aluminum housing, 3 interfaces in a device can be selected via DIP switches, Infrared light, Mating connector with protective cover included deliveryfa
Indisponível para compra: Print mark color sensor, stainless steel housing, 9.5 mm detection range, RGB light with rectangular light spot, external Teach-In, Teach-In button, NPN output, PNP output, M12 plug, Diffuse mode sensor for recording colored print marks on backgrounds with different colors, Teach-in procedure for automatic threshold value setting, 3 emitter colors: green, red and blue, Very short response time, Optical system exchangeable by 90°fa
O sistema de sensor ultrassônico de segurança USi está abrindo novos caminhos para aplicações de segurança, seja em ambientes desafiadores, empoeirados ou em áreas externas Saiba mais sobre o sistema de sensores ultrassônicos de segurança USi ... de Sensor USi®-safety de acordo com a Categoria 3 PL d Tecnologia ultrassônica para segurança em todas as áreas O sistema de sensor ultrassônico de segurança USi está abrindo novos caminhos para aplicações de segurança, seja em ambientes desafiadores ...
No transp autônomo, devem-se monitorar a direção de deslocamento e as laterais dos AGVs para evitar colisões Os sistemas de sensores ultrassônicos de segurança USi detectam todos os obstáculos em uma área de segurança definida ... interferências. A proteção deve estar em conformidade com a norma ISO 13849-1, categoria 3 PL d . Solução Sensor ultrassônico de segurança USi Vários sensores ultrassônicos de segurança USi são distribuídos em cada lado do veículo. Compacta, a unidade de sensor ...
Alinhamento preciso de heliostatos em usinas elétricas de torre solar usando codificadores rotativos e sensores de inclinação que detectam posições ao longo de dois eixos ... é direcionada a um receptor, uma pequena área no topo da torre. O calor resultante (até 800 °C ) é usado para gerar vapor para alimentar uma usina de turbina. A maioria das usinas está localizada em áreas desérticas ou com alto grau de radiação solar ...
Manter uma usina elétrica operacional e operando é fundamental A Pepperl+Fuchs oferece tecnologias inovadoras de barramento de campo e soluções eficientes para usinas elétricas ... + águas residuais Indústrias de energia Os setores de geração de energia contam com a Pepperl+Fuchs. Muitas usinas de energia nuclear e de combustíveis fósseis em todo o mundo estão envelhecendo rapidamente. Muitas dessas usinas de energia estão planejando ...
Seja em usinas parabólicas, sistemas Fresnel ou torres de energia solar: A tecnologia de sensor da Pepperl+Fuchs resiste facilmente às condições ambiente extremas em usinas solares de energia térmica Saiba mais ... Hidrogênio Armazenamento da bateria Movimentação de Material e Logística Indústria de embalagens Equipamentos de Processos Automação para Acesso Electronics Industry Usinas solares de energia térmica A temperatura da superfície do sol é de cerca de 5.800 °C ...
1-5/74Itens por Página:
Não encontrou nenhum resultado?
Dica: Digite o caractere * antes do termo a ser pesquisado, modifique sua pesquisa, verifique os termos ou entre em contato conosco.