Sensing range up to 30 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Sturdy housing, Waterproof, degree of protection IP67, Operation on SB4-series control units (SafeBox), Construction type(S2): Rectangular type, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Connection: M12 connector, 4-pin
Sensing range up to 65 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Sturdy housing, Waterproof, degree of protection IP67, Operation on control units of SB4 (SafeBox), Construction type(S2): Rectangular type, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Connection: M12 connector, 4-pin
Sensing range up to 30 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Extended temperature range up to -35 °C with heated front panel, Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Operation of control units of Series SB4, Construction type(S2): Rectangular type, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Connection: M12 connector, 5 pin
Sensing range up to 10 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Sturdy housing, Waterproof, degree of protection IP67, Operation on control units of SB4 (SafeBox), Construction type(S2): Miniature housing, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Connection: 2.5 m, 5-wire, fixed cable, Euronorm
Sensing range up to 10 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Sturdy housing, Waterproof, degree of protection IP67, Operation on control units of SB4 (SafeBox), Construction type(S2): Miniature housing, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Connection: 5-pin M12 x 1 connector with metal thread, 90° rotatable
Sensing range up to 30 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Sturdy housing, Waterproof, degree of protection IP67, Operation on control units of SB4 (SafeBox), Construction type(S2): Rectangular type, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Connection: terminal compartment
Sensing range up to 65 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Sturdy housing, Waterproof, degree of protection IP67, Operation on control units of SB4 (SafeBox), Construction type(S2): Rectangular type, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Connection: terminal compartment
Sensing range 12 m, Visible red light, pulsed LASER light, Laser class 1, eyesafe, Performance Level PL e, Clearly visible LED functional display and pre-fault indicator on the receiver, Sturdy housing, Waterproof, degree of protection IP67, Operation on SB4-series control units (SafeBox), Construction type(S2): Miniature housing, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Connection: 5-pin M12 x 1 connector with metal thread, 90° rotatable
Sensing range 30 m, Visible red light, pulsed LASER light, Laser class 1, eyesafe, Performance Level PL e, Clearly visible LED functional display and pre-fault indicator on the receiver, Sturdy housing, Waterproof, degree of protection IP67, Operation on control units of SB4 (SafeBox), Construction type(S2): Miniature housing, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Connection: 5-pin M12 x 1 connector with metal thread, 90° rotatable
Sensing range up to 65 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Extended temperature range up to -35 °C with heated front panel, Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Operation on control units of SB4 (SafeBox), Construction type(S2): Rectangular type, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Connection: M12 connector, 5 pin
Sturdy housing, Sensing range 20 m, Sleek design, Simple alignment, Indicator LED on the front, Function: Secure, Sensor principle: Thru-beam sensor, Operating voltage: 10 ... 24 V DC, Output type: OSE, Signal output: 900 Hz , transistor output loadable with max. 20 mA, short-circuit protected, Connection: fixed black cable , Emitter: 0.14 mm2 , 3 conductor , Receiver: 0.14 mm2 , 3 conductor
Sturdy housing, Sensing range 20 m, Sleek design, Simple alignment, Indicator LED on the front, Function: Secure, Sensor principle: Thru-beam sensor, Operating voltage: 10 ... 30 V DC, Output type: relay, change-over contact, Connection: fixed black cable , Emitter: 0.25 mm2 , 3 conductor , Receiver: 0.25 mm2 , 5-wire
Sensor module, 6 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housing, Connection: screw terminals , lead cross section 0.2 ... 2 mm2
Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Micro-Controller controls, Operating mode can be selected by means of DIP switches, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housing, Connection: screw terminals , lead cross section 0.2 ... 2 mm2
Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housing
Safety control unit, Safety category 3 in accordance with ISO 13849-1, Power/function indicator LEDs, Signaling contacts with wiper function, one OSE input, Function: Switch device for sensor supply, Operating voltage: , 230 V AC ± 10 %, Output type: relay, NO contact, Connection: screw terminals , lead cross section 2 x 1 mm2
Safety thru-beam sensor, Evaluation via safety control unit PSE4-SC-01, Modulated infrared light, For mounting in sensor strip PSE4-RUB and -ROI, No additional mounting materials required, Component of PSE4 modular system
Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Micro-Controller controls, Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housing
Safety control unit, For evaluating safety thru-beam sensors PSE4-SL, Safety category 4 according to EN61496-1, 24 V DC supply voltage, 2 safe output contacts, Performance level PLe (EN13849-1) is attainable, Component of PSE4 modular system, Number of channels: 1-channel, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC +20/-10 %, Connection: screw terminals , Cable cross-section 0.2 ... 2.5 mm2
Safety control unit, For evaluating safety thru-beam sensors PSE4-SL, Safety category 3 according to EN61496-1, 24 V DC supply voltage, 1 safe output contact, Performance level PLd (EN13849-1) is attainable, Component of PSE4 modular system, Number of channels: 4-channel, Performance level (PL): PL d, Category: Cat. 3, Operating voltage: 24 V DC +20/-10 % , 24 V AC ± 10 %, Connection: screw terminals , lead cross section 2 x 1 mm2
Sensor module, 4 sensor channels, Operating mode can be selected by means of DIP switches, Individual module for SLA5(S), SLA20, SLA25, SLA28 and SLA40 security through-beam sensors; for SLP safety light grids, for SLC safety light curtains; for switching pads and emergency stop buttons of categories 2 or 4, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housing
Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), 4 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Stability alarm indication, Clearly visible LED functional display, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC, ± 20 %
Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), 8 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Stability alarm indication, Clearly visible LED functional display, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC, ± 20 %
Safety thru-beam sensor, Modulated infrared light, No additional mounting materials required, For mounting GP series rubber profiles, Comprehensive accessories, Function: Secure, Sensor principle: Thru-beam sensor, Operating voltage: battery operated 3 ... 6 V DC , Coiled Cable: 9 ... 27 V DC, Output type: OSE, Signal output: 900 Hz , transistor output loadable with max. 20 mA, short-circuit protected, Connection: PUR cable , 0.14 mm2 3 conductor , halogen-free
Sensor module, 4 sensor channels, Micro-Controller controls, Operating mode can be selected by means of DIP switches, Individual module for SLA5(S), SLA20, SLA25, SLA28 and SLA40 security through-beam sensors; for SLP safety light grids, for SLC safety light curtains; for switching pads and emergency stop buttons of categories 2 or 4, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4
Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4, 4 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Stability alarm indication, Clearly visible LED functional display, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e
Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4, 8 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Stability alarm indication, Clearly visible LED functional display, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e
closing edge monitoring for industrial doors up to 12 m width, for use in GP series rubber profiles, Safety thru-beam sensor with OSE output, Comprehensive accessories, Function: Secure, Sensor principle: Thru-beam sensor, Operating voltage: battery operated 3 ... 6 V DC , Coiled Cable: 9 ... 27 V DC, Output type: OSE, Signal output: 900 Hz , Transistor output loadable with max. 20 mA , short-circuit protected
Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), 4 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Sequential and parallel muting in various operating modes, Double muting, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC, ± 20 %
Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4, 4 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Sequential and parallel muting in various operating modes, Double muting, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e
closing edge monitoring for industrial doors up to 12 m width, for use in GP series rubber profiles, Safety thru-beam sensor with OSE output, Extremely low quiescent current, Comprehensive accessories, Function: Secure, Sensor principle: Thru-beam sensor, Operating voltage: battery operated 3 ... 6 V DC , Coiled Cable: 9 ... 27 V DC, Output type: OSE, Signal output: 900 Hz , Transistor output loadable with max. 20 mA , short-circuit protected
Compact fire protection photoelectric sensor for safety devices on fire barriers, Approval in accordance with VdS Test Report FSA and externally monitored manufacture (Ü Symbol), Not sensitive to ambient light, even with switched energy saving lamps, Light source: LED, Light type: modulated visible red light , 660 nm, Operating voltage: 12 ... 240 V AC/DC, Switching type: light/dark on, switchable (selectable, light/dark switching is only activated if the receiver has 'dark on' selected.)
Compact fire protection photoelectric sensor for safety devices on fire barriers, Approval in accordance with VdS Test Report FSA and externally monitored manufacture (Ü Symbol), Not sensitive to ambient light, even with switched energy saving lamps, Light source: LED, 660 nm and IRED, 880 nm, Light type: modulated visible red light and modulated infrared light, Control elements: Light-on/dark-on changeover switch ; Time adjuster, Operating voltage: 12 ... 240 V AC/DC
Small fire protection photoelectric sensor for safety devices on fire barriers, Approval in accordance with VdS Test Report FSA and externally monitored manufacture (Ü Symbol), High protection against contact, Not sensitive to ambient light, even with switched energy saving lamps, Effective detection range: 0 ... 2.1 m (with H60 reflector), Light source: LED 645 nm, Light type: modulated visible red light, Operating voltage: 10 ... 30 V DC, Switching type: light/dark on switchable
OSSD-R/E-stop-module, Safety outputs OSSD, external status displays OSSD, 2 sensor channels, Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Stop function Cat.0 or Cat.1 and central stop function Cat.0, Time function, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , , 24 V DC ± 20 % , via SB4 Housing
Safety control unit, Signaling contacts with wiper function, one OSE input, force-guided safety relay, Power/function indicator LEDs, Function: Switch device for sensor supply, Operating voltage: , 24 V AC/DC ± 10 %, Output type: relay, NO contact, Connection: screw terminals , lead cross section 2 x 1 mm2
Safety control unit, 2-channel interpreter, for two optical closing edge protection devices, two "TWIN-PRO" pull-in protection devices, or two LIGIs with OSE outputs, Two OSE inputs or 8k2 inputs, one safety circuit, Function: Switch device for sensor supply, Operating voltage: , 230 V AC ± 10 %, Output type: relay, NO contact, Connection: screw terminals , lead cross section 2 x 1 mm2
Safety control unit, 2-channel interpreter, for two optical closing edge protection devices, two "TWIN-PRO" pull-in protection devices, or two LIGIs with OSE outputs, Two OSE inputs or 8k2 inputs, one safety circuit, Function: Switch device for sensor supply, Operating voltage: , 24 V AC/V DC ± 10 %, Output type: relay, NO contact, Connection: screw terminals , lead cross section 2 x 1 mm2
Safety control unit, one OSE input, LED display indicators, for door leaf mounting, relay output and test input, Function: Switch device for sensor supply, Operating voltage: 19 ... 35 V DC , 19 ... 30 V AC, Output type: relay, change-over contact, Connection: screw terminals , lead cross section 2 x 1 mm2
Muting module, 4 sensor channels, Double muting, Emergency muting for the correction of the material jam, Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , , 24 V DC ± 20 % , via SB4 Housing
Muting module, 4 sensor channels, Double muting, Continuous muting with no time limit, Emergency muting for the correction of the material jam, Operating mode can be selected by means of DIP switches, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , , 24 V DC ± 20 % , via SB4 Housing, Connection: screw terminals , lead cross section 0.2 ... 2 mm2
Aluminum mounting strip, For mounting rubber sensor strips PSE4-RUB and -ROI, Simple to customize to application, Possible to connect in series, Component of PSE4 modular system
Aluminum mounting strip, For mounting rubber sensor strips PSE4-RUB-30EPDM, Simple to customize to application, Possible to connect in series, Component of PSE4 modular system
Eight grooves for mounting photoelectric sensors or accessories, three on the inside and five on the outside, Corner mounting of photoelectric sensors with a directional difference of 90°, Cover prepared for indicator light mounting, Safety Series: SLCT / SLCS
50 / 56
SISTEMA - Safety Integrity Software Tool for the Evaluation of Machine Applications EN ISO 13849-1
Combined sensor for opening and securing automatic sliding doors, Radar opening impulse, Closing edge safety mechanism with diffuse sensor, Safety mechanism in accordance with EN 16005, Extra-large, adjustable protection field in front of the door, Function: Open and secure, Sensor principle: Area scanner, Operating voltage: 12 ... 24 V DC / 12 ... 24 V AC +/- 10%, 50 - 60 Hz, Switching type: light/dark on selectable programmable, Output type: Radar, relay
Weld immune proximity sensors, Switching function: 2 x normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Construction type: Rectangular, Series: Rectangular type, Operating voltage: 10 ... 30 V DC, Type of voltage: DC, Connection type: Connector plug, Housing material: amplifier; PBT, PA6 + GD-ZN AL4, oscillators; PBT, Degree of protection: IP65, Threading: M12 x 1
Switching function: 2 x normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 4-wire, Construction type: VariKont L ®, Series: VariKont L ®, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: Connector plug, Housing material: PA-GF35 , powder coated metal mounting flange, Degree of protection: IP68 / IP69, Threading: M12 x 1
Switching function: 2 x normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Construction type: VariKont L ®, Series: VariKont L ®, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: Connector plug, Housing material: PA-GF35 , powder coated metal mounting flange, Degree of protection: IP68 / IP69, Threading: M12 x 1
Evaluation unit exclusively for the ultrasonic sensor system USi-safety, Categorie 3 PL d (EN ISO 13849) for each ultrasonic transducer without redundancy, Multiple device installation possible, no mutual interference (no cross-talk), Safety outputs OSSD, Sensing range: 1 ... 250 cm , typ. 200 cm, Series: USi-safety, Performance level (PL): PL d, Operating voltage: 21 ... 28 V DC , typ. 24 V DC, Interface type: USB 2.0
Output type: NAMUR, Safety Integrity Level (SIL): SIL 2
Fan-shaped detection field with up to 12 beams, Closing safety monitoring over the complete door width, Adjustable detection fields for different door widths, Automatic drift compensation, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 36 V DC, Signal output: Relay, 1 alternator, Connection: 5 m fixed cable
Extended temperature range, Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Output type: 2-wire, Construction type: Slot, Series: Slot type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Da: IECEx PTB 11.0092X, Equipment protection level Mb: IECEx PTB 11.0092X
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Output type: 2-wire, Construction type: Slot, Series: Slot type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Da: IECEx PTB 11.0092X, Equipment protection level Mb: IECEx PTB 11.0092X, Equipment protection level Ga: PTB 00 ATEX 2049 X
Extended temperature range, Suitable for 2:1 technology, Switching function: Normally open (NO), Output type: NAMUR with safety function, Output type: 2-wire, Construction type: Slot, Series: Slot type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Da: IECEx PTB 11.0092X, Equipment protection level Mb: IECEx PTB 11.0092X
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Output type: 2-wire, Construction type: Slot, Series: Slot type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Da: IECEx PTB 11.0092X, Equipment protection level Mb: IECEx PTB 11.0092X, Equipment protection level Gb: PTB 00 ATEX 2049 X, Equipment protection level Da: PTB 00 ATEX 2049 X
Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: non-flush, Output type: 2-wire, Construction type: Rectangular, Series: Rectangular type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Da: IECEx PTB 11.0092X, Equipment protection level Mb: IECEx PTB 11.0092X, Equipment protection level Gb: PTB 00 ATEX 2049 X, Equipment protection level Da: PTB 00 ATEX 2049 X
Fan-shaped detection field with up to 12 beams, Closing safety monitoring over the complete door width, Adjustable detection fields for different door widths, Automatic drift compensation, Version with test input, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 36 V DC, Signal output: 1 PNP, short-circuit protected, reverse polarity protected, open collector, Connection: 5 m fixed cable
Fan-shaped detection field with up to 12 beams, Closing safety monitoring over the complete door width, Adjustable detection fields for different door widths, Automatic drift compensation, Version with test input, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 36 V DC, Signal output: relay, 1 NO, Connection: 5 m fixed cable
Temperature sensor exclusively for the USi-safety evaluation unit, Compact design, Universal orientation, Mounting holes for simple installation, Ambient temperature: movable cable: -25 ... 80 °C (-13 ... 176 °F) , cable, fixed installation: -40 ... 80 °C (-40 ... 176 °F), Connection type: fixed cable with plug, Housing: TPU, Threading: M8 x 1
Series: Performance Plus Line, Measured variable: Vibration velocity, Frequency range: 10 ... 1000 Hz, Averaging time: for v-rms: 2 s, Ambient temperature: -40 ... 60 °C (-40 ... 140 °F), Measuring head temperature: -40 ... 125 °C (-40 ... 257 °F) directly at the mounting point, Storage temperature: -40 ... 60 °C (-40 ... 140 °F), Connection type: plug, Housing material: Stainless steel 1.4305 / AISI 303 - Vibration sensor with analog current output, increased temperature resistance, suitable up to Zone 1/21 with type of protection intrinsic safety, Series: Performance Plus Line, Measured variable: Vibration velocity, Output type: analog output, current , output of the vibration variable, Equipment protection level Gb: IECEx CSAE 22.0042X, Equipment protection level Db: IECEx CSAE 22.0042X, Equipment protection level Gb: CSANe 21 ATEX 1074 X, Equipment protection level Db: CSANe 21 ATEX 1074 X
Switching function: 2 x normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 4-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: cable, Housing material: brass, nickel-plated, Degree of protection: IP68 / IP69, Material: PUR
Switching function: 2 x normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 4-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: cable, Housing material: brass, nickel-plated, Degree of protection: IP68 / IP69, Material: PVC
Switching function: 2 x normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 4-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: cable, Housing material: brass, nickel-plated, Degree of protection: IP68 / IP69, Material: PUR
Switching function: 2 x normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 4-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: cable, Housing material: brass, nickel-plated, Degree of protection: IP68 / IP69, Material: PVC
Switching function: 2 x normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: cable, Housing material: brass, nickel-plated, Degree of protection: IP68 / IP69, Material: PUR
Switching function: 2 x normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: cable, Housing material: brass, nickel-plated, Degree of protection: IP68 / IP69, Material: PUR
Switching function: 2 x normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: cable, Housing material: brass, nickel-plated, Degree of protection: IP68 / IP69, Material: PUR
Switching function: 2 x normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 4-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: cable, Housing material: brass, nickel-plated, Degree of protection: IP68 / IP69, Material: PUR
Switching function: 2 x normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: cable, Housing material: brass, nickel-plated, Degree of protection: IP68 / IP69, Material: PVC
Switching function: 2 x normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 4-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: cable, Housing material: brass, nickel-plated, Degree of protection: IP68 / IP69, Material: PVC
Switching function: 2 x normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: cable, Housing material: brass, nickel-plated, Degree of protection: IP68 / IP69, Material: PVC
Switching function: 2 x normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Performance level (PL): PL d, Type of voltage: DC, Connection type: cable, Housing material: brass, nickel-plated, Degree of protection: IP68 / IP69, Material: PVC
Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: non-flush, Output type: 2-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017X, Equipment protection level Da: IECEx PTB 11.0092X
Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Construction type: Cylindrical, flat, Series: Cylindrical type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017X
Extended temperature range, Switching function: Normally open (NO), Output type: NAMUR with safety function, Installation: flush in mild steel, Output type: 2-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017X
Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017X, Equipment protection level Da: IECEx PTB 11.0092X
Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017X
Suitable for 2:1 technology, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Thread mold: M14, Construction type: Cylindrical, thread, Series: Cylindrical type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017X
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017X, Equipment protection level Da: IECEx PTB 11.0092X
Extended temperature range, Suitable for 2:1 technology, Switching function: Normally open (NO), Output type: NAMUR with safety function, Installation: flush in mild steel, Output type: 2-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: non-flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017X, Equipment protection level Da: IECEx PTB 11.0092X
Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR with safety function, Installation: flush, Output type: 2-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 3, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0092X, Equipment protection level Gb: IECEx PTB 11.0092X, Equipment protection level Gc (ec): IECEx TUR 21.0017X, Equipment protection level Da: IECEx PTB 11.0092X