Print mark contrast sensor, 11 mm detection range, RGB light parallel with the longitudinal direction of the housing, light/dark ON, external Teach-In, 2 push-pull outputs, M12 plug, Diffuse mode sensor for recording any print mark, Teach-in, static and dynamic, 50 µs response time, suitable for extremely rapid scanning processes, 3 emitter colors: green, red and bluefa
Photoelectric slot sensor, zinc pressure diecast housing, 30 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
Photoelectric slot sensor, zinc pressure diecast housing, 80 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: resistance thermometer, Signal: Resistancepa
1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, HART communication, Safety Integrity Level (SIL): SIL 3, Rated voltage: 0 ... 24 V DC , loop powered, Signal: 1 x 1 ... 20 mA, Signal [2]: 1 x HART, Device: 1 x fire alarm, Signal: 1 x 1 ... 20 mApa
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, HART communication, Trip relay, Safety Integrity Level (SIL): SIL 2pa
1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART-IP and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Signal: 2 x 4 ... 20 mA, Line fault detectionpa
2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART-IP and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Transfer direction: to the field, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Signal: 2 x 4 ... 20 mA, Line fault detectionpa
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x Transistor (passive)pa
Indisponível para compra: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Indisponível para compra: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Indisponível para compra: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Indisponível para compra: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Indisponível para compra: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Indisponível para compra: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Indisponível para compra: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Indisponível para compra: 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 65 mA at 9.8 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: 20 ... 35 V DC , loop powered, Type: field device supply, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarm, Current: ≤ 65 mA, Voltage: ≥ 9.8 Vpa
Indisponível para compra: 2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: logic input, Field device: 2 x Valve, Field device [2]: 2 x audible alarm, Field device [3]: 2 x visual alarm, Current: ≤ 45 mA, Voltage: ≥ 11.7 Vpa
Indisponível para compra: Universal thru-beam sensor, large housing design, 60 m detection range, infrared light, light/dark on, detection range adjuster, DC version, 2 push-pull outputs, adjustable timer functions, M12 plug, Cost-optimized series for standard tasks in a special design, Compact design, Wide range of mounting options thanks to cubic housing design with M30 thread, 360° high visibility LEDs, Programmable ON-delay, OFF-delay, and One-shot timersfa
O sistema de sensor ultrassônico de segurança USi está abrindo novos caminhos para aplicações de segurança, seja em ambientes desafiadores, empoeirados ou em áreas externas Saiba mais sobre o sistema de sensores ultrassônicos de segurança USi ... de Sensor USi®-safety de acordo com a Categoria 3 PL d Tecnologia ultrassônica para segurança em todas as áreas O sistema de sensor ultrassônico de segurança USi está abrindo novos caminhos para aplicações de segurança, seja em ambientes desafiadores ...
No transp autônomo, devem-se monitorar a direção de deslocamento e as laterais dos AGVs para evitar colisões Os sistemas de sensores ultrassônicos de segurança USi detectam todos os obstáculos em uma área de segurança definida ... interferências. A proteção deve estar em conformidade com a norma ISO 13849-1, categoria 3 PL d . Solução Sensor ultrassônico de segurança USi Vários sensores ultrassônicos de segurança USi são distribuídos em cada lado do veículo. Compacta, a unidade de sensor ...
Alinhamento preciso de heliostatos em usinas elétricas de torre solar usando codificadores rotativos e sensores de inclinação que detectam posições ao longo de dois eixos ... é direcionada a um receptor, uma pequena área no topo da torre. O calor resultante (até 800 °C ) é usado para gerar vapor para alimentar uma usina de turbina. A maioria das usinas está localizada em áreas desérticas ou com alto grau de radiação solar ...
Manter uma usina elétrica operacional e operando é fundamental A Pepperl+Fuchs oferece tecnologias inovadoras de barramento de campo e soluções eficientes para usinas elétricas ... + águas residuais Indústrias de energia Os setores de geração de energia contam com a Pepperl+Fuchs. Muitas usinas de energia nuclear e de combustíveis fósseis em todo o mundo estão envelhecendo rapidamente. Muitas dessas usinas de energia estão planejando ...
A segurança contra poeira de carvão em usinas a carvão é um desafio físico para os operadores de usinas de energia A Pepperl+Fuchs oferece produtos que suportam maior segurança e menor risco em usinas elétricas ... + águas residuais Usinas elétricas de energia – Carvão, óleo, gás natural Usina a carvão A segurança contra poeira de carvão em usinas a carvão é um desafio físico para os operadores de usinas de energia . As poeiras de carvão têm um potencial de incêndio ...
Seja em usinas parabólicas, sistemas Fresnel ou torres de energia solar: A tecnologia de sensor da Pepperl+Fuchs resiste facilmente às condições ambiente extremas em usinas solares de energia térmica Saiba mais ... Hidrogênio Armazenamento da bateria Movimentação de Material e Logística Indústria de embalagens Equipamentos de Processos Automação para Acesso Electronics Industry Usinas solares de energia térmica A temperatura da superfície do sol é de cerca de 5.800 °C ...
A Pepperl+Fuchs oferece um portfólio abrangente de tecnologia de sensores industriais para a produção automatizada de wafers PV, células PV e módulos PV Saiba mais ... Mercados+Aplicações Máquinas e Instalações Indústria automotiva Equipamentos Móveis Energia renovável Energia solar Sistemas de rastreamento em usinas fotovoltaicas Produção de sistemas fotovoltaicos Usinas solares de energia térmica Energia eólica ...
Os sensores da Pepperl+Fuchs suportam a operação eficiente de sistemas fotovoltaicos, bem como usinas solares de energia térmica Saiba mais ... solar em energia elétrica, as usinas solares de energia térmica usam o calor do sol para isso. Tanto os sistemas PV como as usinas solares de energia térmica contêm módulos ou espelhos que capturam a energia do sol. Quanto mais precisamente ...
A Pepperl+Fuchs oferece codificadores rotativos incrementais resistentes para usinas eólicas costeiras ... do que as usinas terrestres comparáveis. Isso envolve uma ampla gama de aplicações de medição e posicionamento que são resolvidas por componentes elétricos. A medição de velocidade dos geradores de turbina de vento é uma das aplicações padrão desta indústria ...
A Pepperl+Fuchs oferece sensores industriais para garantir o alinhamento preciso dos módulos fotovoltaicos, maximizando a produção solar Saiba mais ... Hidrogênio Armazenamento da bateria Movimentação de Material e Logística Indústria de embalagens Equipamentos de Processos Automação para Acesso Electronics Industry Sistemas de rastreamento em usinas fotovoltaicas Os sistemas fotovoltaicos geram eletricidade ...
1-10/74Itens por Página:
Não encontrou nenhum resultado?
Dica: Digite o caractere * antes do termo a ser pesquisado, modifique sua pesquisa, verifique os termos ou entre em contato conosco.