Print mark contrast sensor, 11 mm detection range, RGB light parallel with the longitudinal direction of the housing, light/dark ON, external Teach-In, 2 push-pull outputs, M12 plug, Diffuse mode sensor for recording any print mark, Teach-in, static and dynamic, 50 µs response time, suitable for extremely rapid scanning processes, 3 emitter colors: green, red and bluefa
Photoelectric slot sensor, zinc pressure diecast housing, 30 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
Photoelectric slot sensor, zinc pressure diecast housing, 80 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: resistance thermometer, Signal: Resistancepa
1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, HART communication, Safety Integrity Level (SIL): SIL 3, Rated voltage: 0 ... 24 V DC , loop powered, Signal: 1 x 1 ... 20 mA, Signal [2]: 1 x HART, Device: 1 x fire alarm, Signal: 1 x 1 ... 20 mApa
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, HART communication, Trip relay, Safety Integrity Level (SIL): SIL 2pa
1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART-IP and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Signal: 2 x 4 ... 20 mA, Line fault detectionpa
2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART-IP and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Transfer direction: to the field, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Signal: 2 x 4 ... 20 mA, Line fault detectionpa
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x Transistor (passive)pa
Indisponível para compra: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Indisponível para compra: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Indisponível para compra: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Indisponível para compra: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Indisponível para compra: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Indisponível para compra: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Indisponível para compra: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Indisponível para compra: 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 65 mA at 9.8 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: 20 ... 35 V DC , loop powered, Type: field device supply, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarm, Current: ≤ 65 mA, Voltage: ≥ 9.8 Vpa
Indisponível para compra: 2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: logic input, Field device: 2 x Valve, Field device [2]: 2 x audible alarm, Field device [3]: 2 x visual alarm, Current: ≤ 45 mA, Voltage: ≥ 11.7 Vpa
Indisponível para compra: Universal thru-beam sensor, large housing design, 60 m detection range, infrared light, light/dark on, detection range adjuster, DC version, 2 push-pull outputs, adjustable timer functions, M12 plug, Cost-optimized series for standard tasks in a special design, Compact design, Wide range of mounting options thanks to cubic housing design with M30 thread, 360° high visibility LEDs, Programmable ON-delay, OFF-delay, and One-shot timersfa
A Pepperl+Fuchs oferece um sensor ultrassônico para operação segura de sistemas automatizados de transporte guiado em hospitais° ... e do ombro do pessoal na pista seja detectada para evitar lesões por colisões. A Solução A segurança USi® é um sistema de sensor ultrassônico que mantém a segurança do pessoal. Sua unidade de sensor que detecta obstáculos de forma confiável é pequena ...
A Pepperl+Fuchs oferece um sistema de sensores ultrassônicos em conformidade com a norma EN ISO 13849 categoria 3 PL d para navegação segura de AGVs em depósitos° ... 13849-1 categoria 3 PL d é necessária para esses requisitos de aplicação. Deve ser possível usar esses dispositivos em espaços confinados e eles devem ser resistentes a influências ambientais , como poeira, sujeira e umidade. A Solução A segurança USi ...
Ver Todos: Os sensores de monitoramento de área da Pepperl+Fuchs, como o Detector SmartRunner, são otimizados para um monitoramento altamente preciso ... set as needed using Data Matrix control codes—all without the use of a PC. The laser profile sensor can also be quickly and easily aligned with natural objects such as a wall. This eliminates the additional effort of alignment as well as duplicate ...
Explore a base de conhecimento da Pepperl+Fuchs para saber mais sobre os designs de invólucro dos sensores indutivos ... para correntes de esteiras Certificações: CE, UL/CSA Retardante de chamas Livre de halogênio Resistente à hidrólise Aplicações típicas: correntes de esteira, ferramentas de usinagem, construção de instalação, processamento de pintura, indústria automotiva ...
Explore a base de conhecimento da Pepperl+Fuchs para saber mais sobre as condições ambiente dos sensores indutivos ... ou ferramentas de usinagem. A Pepperl+Fuchs tem uma ampla linha de sensores à prova de solda em seu portfólio de produtos. Robustez Os sensores com invólucro de aço inoxidável hermeticamente vedado são usados especialmente para aplicações de lavagem , nas quais ...
De posicionamento e identificação confiáveis à garantia de processos fáceis em tecnologia de transportadoras e aplicações críticas de segurança, conheça nosso abrangente portfólio para a indústria aut ... protected using state-of-the-art ultrasonic technology and all of the advantages this brings. IO-Link Infraestrutura completa para aplicativos de IoT Com a aquisição dos negócios da Comtrol Corporation, a Pepperl+Fuchs aprimora seu portfólio para comunicação ...
O versátil Ex-Handy 10 é uma solução de telefone com recursos básicos completamente desenvolvida por nós, que vem com uma bateria potente e pode operar com botão de chamada e tela sensível ao toque C ... from application engineering consulting, customer-specific pre-configuration, and mobile device commissioning to mobile device management . With this tool, users can view their products’ software and configurations and manage them using a remote ...
Ver Todos: Você está procurando uma solução móvel para uso em ambientes industriais adversos até Zona 1/21 e Divisão 1? Obtenha uma visão geral da linha completa de tablets Android e Windows intrinsec ... proves to be the ideal companion for mobile workers in the field and for implementing IIoT applications. The tablet can be connected to a large screen and a keyboard using Samsung's Desktop Experience (DeX) feature. As an Android Enterprise recommended ...
... switching distances by generating an electromagnetic field and using changes in the magnetic field to determine whether an object is in the sensor’s detection range . Metallic components around a sensor weaken the magnetic field and thus the sensor’s range ...
Krifft & Zipsner GmbH supplies printing machines with automated logistics systems at delivery and in feed All operator-accessible points on the machine are monitored with safety light barriers and li ... system components. Configurable without PC Another important reason why the logistics specialist Krifft & Zipsner decided to use Safebox is that it can be commissioned and maintained without using a PC. No programming, linking of inputs and outputs ...
41-50/74Itens por Página:
Não encontrou nenhum resultado?
Dica: Digite o caractere * antes do termo a ser pesquisado, modifique sua pesquisa, verifique os termos ou entre em contato conosco.