762 mm x 508 mm x 215 mm, 316L Stainless Steel, Ex e, Ex ia and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Straight Edge Sealing, No Gland Plate, Customizable configuration of terminals, cable entries and cable gland types as per specification, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa
Non disponibile per l'acquisto: For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Non-hazardous area: screw terminals, black, Number of modules: 8, Number of channels per module: 2 , 4, Signal type: Universal, Manufacturer: Universal, Control system type: Universalpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Non disponibile per l'acquisto: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Non disponibile per l'acquisto: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Non disponibile per l'acquisto: Funzione di commutazione: Normalmente aperto/chiuso (NO/NC) programmabile, Tipo di uscita: Interfaccia AS, Montaggio incorporato: non incorporab., Tipo di uscita: 2-fili, Tipo di costruzione: VariKont L®, Serie: VariKont L®, Tensione di esercizio: 26,5 ... 31,9 V Con sistema bus AS-i, Tipo di tensione: DC, Tipo di collegamento: Connettore a spina M12 x 1 , 4 poli, Materiale della scatola: PA, Grado di protezione: IP67fa
Non disponibile per l'acquisto: Funzione di commutazione: Normalmente aperto/chiuso (NO/NC) programmabile, Tipo di uscita: Interfaccia AS, Montaggio incorporato: non incorporab., Tipo di uscita: 2-fili, Stampo filettato: M12, Tipo di costruzione: Cilindrico, filo, Serie: cilindrico, altro, Tensione di esercizio: 26,5 ... 31,9 V Con sistema bus AS-i, Tipo di tensione: DC, Tipo di collegamento: Connettore a spina M12 x 1 , 4 poli, Materiale della scatola: Acciaio inox 1.4305 / AISI 303, Grado di protezione: IP67fa
Il sensore ad ultrasuoniWILSEN di Pepperl+Fuchs, basato su LoRaWAN, è una soluzionerobusta per il monitoraggio del livello di riempimento e la misurazione della distanza ... sensorsfromPepperl+Fuchs via thedownlinkchannel ? In thisvideo, ourexpertshowsyouhowtosetitupquicklyandeasily. LoRaWAN® IoT per una tecnologia dai numerosivantaggi Come membro della LoRaAlliance®, Pepperl+Fuchs si impegna a garantire ...
Pepperl+Fuchsoffre una soluzione IO-Linkend-to-end che comprende una gamma di sensori e un'infrastruttura IO-Link ... comuni. Supporta, ad esempio, PROFINET, EtherNet/IP, EtherCAT, CC-LinkIEFieldBasic e MODBUSTCP. Inoltre è estremamentepotente, e può essere utilizzato per applicazioni in tempo reale con tempi di ciclo fin nell'arco dei microsecondi, a seconda ...
Scopril'ampiagamma di sistemiHMI di Pepperl+Fuchs per le industrie di processo ... UltraHD (4K) a 60Hz. Dispone, inoltre, di un'interfacciaUSB di tipo C 3.2Gen. 1 e due interfacceUSB di tipo A 2.0. BTC14 Con la sua custodiachiusaIP4x , il thinclient con custodiaindustrialeBTC14 è estremamenterobusto e garantisce la massima ...
Oltre a funzioniormaicollaudate, i tabletTab-Ex® presentanocaratteristicheinnovative, come l'integrazione di applicazioni di realtàaumentata, che semplificanol'implementazione delle applicazioniIndustry40/IIoT ... °C IPratingTab-Ex® 02DZ1: IP64 / IP65Tab-Ex® 02DZ2: IP64 / IP68IP68Battery4,450mAhbatteryforupto11operatinghoursReplaceable7400mAhbatteryforupto14operatinghoursCamera (rearandfront) Rear: 8MPwithflash; front: 5MPoptional ...
LearnmoreaboutthesafeabsolutelinearpositioningsystemsfromPepperl+FuchsforsafetyapplicationsuptoSIL3andPL e ... thepositionandspeedofthevehicles, thereforecreatinganessentialbasisforfunctionalsafety. ThesafePXV/PUSisalsoanidealsolutionforapplicationssuchaselectricmonorailsystemsorstorageandretrievalmachineswhenitcomestosafe ...