Print mark contrast sensor, 11 mm detection range, RGB light parallel with the longitudinal direction of the housing, light/dark ON, external Teach-In, 2 push-pull outputs, M12 plug, Diffuse mode sensor for recording any print mark, Teach-in, static and dynamic, 50 µs response time, suitable for extremely rapid scanning processes, 3 emitter colors: green, red and bluefa
Photoelectric slot sensor, aluminum housing, 10 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
Photoelectric slot sensor, zinc pressure diecast housing, 121 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
Photoelectric slot sensor, aluminum housing, 20 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
Photoelectric slot sensor, zinc pressure diecast housing, 30 mm slot width, infrared light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Infrared lightfa
Photoelectric slot sensor, zinc pressure diecast housing, 30 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
Photoelectric slot sensor, zinc pressure diecast housing, 50 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
Photoelectric slot sensor, zinc pressure diecast housing, 80 mm slot width, infrared light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Infrared lightfa
Photoelectric slot sensor, zinc pressure diecast housing, 80 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
Non disponibile per l'acquisto: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Non disponibile per l'acquisto: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Non disponibile per l'acquisto: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Non disponibile per l'acquisto: Diffuse sensor with measurement core technology, large housing design, background suppression and 3 more adjustable operating modes, IO-Link interface, 800 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable, Cost-optimized series for standard tasks, Sensing-by-ranging functionality, IO-Link interface for service and process data, PowerBeam transmitter LED, Large adjustment range can be precisely definedfa
Non disponibile per l'acquisto: Industrial standard housing ∅58 mm, 200 ppr, Servo flange, 10 V ... 30 V with short-circuit proof push-pull output, Fault indication output*, Enclosure type: 58 mm, Type of shaft: Solid shaft, Interface: push-pull, incremental, Output type: push-pull, incrementalfa
Non disponibile per l'acquisto: Industrial standard housing ∅58 mm, 200 ppr, Servo flange, 10 V ... 30 V with short-circuit proof push-pull output, Fault indication output*, Enclosure type: 58 mm, Type of shaft: Solid shaft, Interface: push-pull, incremental, Output type: push-pull, incrementalfa
Pepperl+Fuchs' rotary encoders are used to slow and control the speed of a process, resulting in increased efficiency ... classic safety considerations that, when properly implemented, lead to productivity increases and cost optimization. Architecture also leads to savings potential by reducing external safety components. This is implemented using a drive-based safety concept ...
In hazardous and industrial environments, documentation of hose checks can be easily done with RFID handhelds from Pepperl+Fuchs and ecom, paired with application-specific software developed by Neocep ... . The integrated 2-D imager allows users to assign additional information to particular components using barcodes or QR codes. When reading the tags, this data can be linked to the other test results. This way, “Mobile Workers” can retrieve ...
In questa pagina sono presenti tutte le note sul rilascio del software thin client Pepperl+Fuchs ... Note sul rilascio del software thin client Pepperl+Fuchs Usi il software thin client Pepperl+Fuchs ? In questa pagina sarà sempre possibile trovare gli ultimi aggiornamenti software per VisuNet RM Shell e VisuNet Control Center . Distinguiamo ...
Vedi panoramica dei prodotti: I nostri sensori a ultrasuoni rappresentano la soluzione ideale per la misurazione della posizione e della distanza senza contatto in tutte le aree industriali Contattac ... per estendere il ciclo di vita dei sensori. NOVITÀ! Misure di sicurezza affidabili in conformità alla Categoria 3 PL d Sistema di sensori a ultrasuoni di sicurezza USi Il sistema di sensori a ultrasuoni di sicurezza USi sta rivoluzionando le applicazioni ...
Pepperl+Fuchs' GOVAN provides you with sturdy, fully certified equipment for switching and monitoring in explosion-hazardous areas ... their own foundries. Using the highest manufacturing standards ensures that we are always able to meet our stringent quality, safety, and reliability standards. Choose Your GOVAN® Product Range If you are already familiar with GOVAN® products, and are ...
Il nuovo e avanzato sistema di purge e pressurizzazione Bebco EPS® è progettato per la Classe I o II/Div 3 e Zona 2/22 Che sia un sistema manuale o automatico, offre tutte le funzionalità necessarie ... costantemente agli utilizzatori un modo sicuro ed economico per installare delle apparecchiature elettriche nelle zone pericolose (classificate). Enviro-Line Volumi della custodia fino a 250 ft 3 (7,08 m 3 ) Usi generici Serie 3000 Volumi della custodia ...
Pepperl+Fuchs' fieldbus handheld FDH-1 has comprehensive monitoring and diagnostics ... . Its comprehensive monitoring and diagnostics enables you to set up a reliable, top quality fieldbus physical layer . Check out five reasons on why using the FDH-1 makes fieldbus installation and maintenance as simple as possible. 1. Familiarity: Take ...
Erfahren Sie mehr zu den Haftungshinweisen zur Nutzung der Pepperl+Fuchs Website ... this Website (the “Information” ) are subject to the following terms of use. 1. Acceptance of Terms By using or visiting the Website (other than to read the “terms of use” for the first time), you agree to comply with all of the terms and conditions ...
Data Matrix ECC 200 from Pepperl+Fuchs allows for fast processing and accurate product identification in pharmaceutical packaging applications ... reading under the stack using an angled optical system and on the reverse side during the traverse. The code has 16 modules and a data content of 16 alphanumeric characters. A module size of 0.4 mm was chosen. This guarantees perfect reading results, even ...
La nuova serie 5500 è la più recente integrazione della linea di sistemi di spurgo e pressurizzazione Bebco EPS di Pepperl+Fuchs ... assoluta, Pepperl+Fuchs offre costantemente agli utilizzatori un modo sicuro ed economico per installare delle apparecchiature elettriche nelle zone pericolose (classificate). Enviro-Line Volumi della custodia fino a 250 ft 3 (7,08 m 3 ) Usi generici Serie ...
41-50/55Elementi per pagina:
Nessun risultato trovato?
Suggerimento: usa il carattere * prima del tuo termine di ricerca, modifica la tua ricerca, verificare i termini di ricerca per gli errori ortografici, contattaci per le tue specifiche richieste.