Non disponibile per l'acquisto: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Non disponibile per l'acquisto: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Non disponibile per l'acquisto: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Non disponibile per l'acquisto: Diffuse sensor with measurement core technology, large housing design, background suppression and 3 more adjustable operating modes, IO-Link interface, 800 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable, Cost-optimized series for standard tasks, Sensing-by-ranging functionality, IO-Link interface for service and process data, PowerBeam transmitter LED, Large adjustment range can be precisely definedfa
Non disponibile per l'acquisto: 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 65 mA at 9.8 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: 20 ... 35 V DC , loop powered, Type: field device supply, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarm, Current: ≤ 65 mA, Voltage: ≥ 9.8 Vpa
Non disponibile per l'acquisto: 2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: logic input, Field device: 2 x Valve, Field device [2]: 2 x audible alarm, Field device [3]: 2 x visual alarm, Current: ≤ 45 mA, Voltage: ≥ 11.7 Vpa
Il sistema di sensori a ultrasuoni di sicurezza USi sta rivoluzionando le applicazioni di sicurezza, sia in ambienti difficili o polverosi sia all'aperto Ulteriori informazioni sul sistema di sensori a ultrasuoni di sicurezza USi ... di sicurezza USi® in conformità alla Categoria 3 PL d Tecnologia a ultrasuoni per una sicurezza estesa a tutte le aree Il sistema di sensori a ultrasuoni di sicurezza USi sta rivoluzionando le applicazioni di sicurezza, sia in ambienti difficili o polverosi ...
In autonomous transport, the direction of travel and the side areas of AGVs must be monitored in order to avoid any collision with people and objects The USi-safety ultrasonic sensor systems reliably detect all obstacles in a defined safety area ... correspondingly large automated guided vehicles (AGV). Additionally, the routes are used by other vehicles, and also by people, either on foot or riding bicycles. The AGV is controlled using an electronic connection to a tag track . However, long tanks require ...
Esplorate la knowledge base (o base di conoscenza) di Pepperl+Fuchs per saperne di più sugli usi idonei dei sensori induttivi ... Esplorate la knowledge base (o base di conoscenza) di Pepperl+Fuchs per saperne di più sugli usi idonei dei sensori induttivi … ...
The German company Wohlenberg Buchbindesysteme (Wohlenberg Bookbinding Systems) is using vision sensors from Pepperl+Fuchs in collating machines and adhesive binders for the detection of incorrect sheets ... . Put into practice The German company Wohlenberg Buchbindesysteme (Wohlenberg Bookbinding Systems) is using Pepperl+Fuchs’ vision sensors in collating machines and adhesive binders to detect incorrect sheets . The sensor’s camera, lighting and ...
La tecnologia di purge e pressurizzazione protegge i dispositivi elettrici per usi generici dall'atmosfera pericolosa circostante collocandoli all'interno di una custodia dal peso leggero Scopri tutti i componenti di cui è composto un sistema ... La tecnologia di purge e pressurizzazione protegge i dispositivi elettrici per usi generici dall'atmosfera pericolosa circostante collocandoli all'interno di una custodia dal peso leggero. Scopri tutt ...