Dane techniczne
UDC-18GMA-400-3E3
General specifications |
Sensing range | 20 ... 60 mm , optimal distance: 45 mm |
Transducer frequency | 395 kHz |
Indicators/operating means |
LED green | indication: single sheet detected |
LED yellow | indication: no sheet detected (Air) |
LED red | indication: double sheet detected |
Electrical specifications |
Operating voltage | 18 ... 30 V DC , ripple 10 %SS |
No-load supply current | < 80 mA |
Time delay before availability | < 500 ms |
Input |
Input type | Function input 0-level: -UB ... -UB + 1V 1-level: +UB - 1 V ... +UB |
Pulse length | ≥ 100 ms |
Impedance | ≥ 4 kΩ |
Output |
Output type | 3 switch outputs PNP, NC |
Rated operating current | 3 x 100 mA , short-circuit/overload protected |
Voltage drop | ≤ 3 V |
Switch-on delay | approx. 15 ms (shorter response time on request) |
Switch-off delay | approx. 15 ms (shorter response time on request) |
Pulse extension | min. 120 ms programmable |
Compliance with standards and directives |
Standard conformity | |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
Approvals and certificates |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | 0 ... 60 °C (32 ... 140 °F) |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications |
Connection type | cable PVC , 2 m |
Core cross section | 0.14 mm2 |
Degree of protection | IP67 |
Material | |
| Housing | nickel plated brass; plastic components: PBT |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
Mass | 150 g |
Dimensions | |
| Length | 74 mm |
| Diameter | 18 mm |
General information |
Supplementary information | Switch settings of the external programming adapter: "output load": pull-down "output logic": inv |
Classifications
System | Classcode |
ECLASS 13.0 | 27272801 |
ECLASS 12.0 | 27272801 |
ECLASS 11.0 | 27272801 |
ECLASS 10.0.1 | 27272801 |
ECLASS 9.0 | 27272801 |
ECLASS 8.0 | 27272801 |
ECLASS 5.1 | 27272801 |
ETIM 9.0 | EC001847 |
ETIM 8.0 | EC001847 |
ETIM 7.0 | EC001847 |
ETIM 6.0 | EC001847 |
ETIM 5.0 | EC001847 |
UNSPSC 12.1 | 41111960 |
Details:
UDC-18GMA-400-3E3
Product Documentation:
UDC-18GMA-400-3E3
Design / Simulation:
UDC-18GMA-400-3E3
Approvals:
UDC-18GMA-400-3E3
Software:
UDC-18GMA-400-3E3
Produkty powiązane:
UDC-18GMA-400-3E3
Accessories |
|
|
|
Programming adapter, USB 2.0 interface, Simple insertion in the sensor connection leadfa |
|
|
|
|
Extension cable for UDB... and UDC...fa |
|
|
|
|
Extension cable for UDB... and UDC...fa |
|
|
|
|
Male cordset, M12, 5-pin, PUR cable with WAGO terminalsfa |
|
|
|
|
Ultrasonic -deflector, Clamp mounting, 90° sound deflection for difficult installation circumstances, Universal Orientationfa |
|
|
|
|
Plastic nuts with centering ring for the vibration-free mounting of cylindrical sensors, For insulated mountingfa |
|