Niedostępne w sprzedaży: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Niedostępne w sprzedaży: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Niedostępne w sprzedaży: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Niedostępne w sprzedaży: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Niedostępne w sprzedaży: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Niedostępne w sprzedaży: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Niedostępne w sprzedaży: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Niedostępne w sprzedaży: Diffuse sensor with measurement core technology, large housing design, background suppression and 3 more adjustable operating modes, IO-Link interface, 800 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable, Cost-optimized series for standard tasks, Sensing-by-ranging functionality, IO-Link interface for service and process data, PowerBeam transmitter LED, Large adjustment range can be precisely definedfa
Data Matrix ECC 200 from Pepperl+Fuchs allows for fast processing and accurate product identification in pharmaceutical packaging applications ... . Data Matrix reading under the stack using an angled optical system and on the reverse side during the traverse. The code has 16 modules and a data content of 16 alphanumeric characters. A module size of 0.4 mm was chosen. This guarantees perfect reading ...
Pepperl+Fuchs offers a wide variety of industrial sensors for sheet fed printing applications ... : Detects media directly while ignoring reflective surfaces close to the target Enhanced edge detection using background suppression sensors Fast response time Cylinder and Part Position Sensor Solution: Inductive sensors, encoders Customer Benefits ...
Pepperl+Fuchs has industrial sensors for customized or standard solutions for digital printing and ATM machines ... identifies consumables by tracking and tracing. Ink substances are also detected through toner cartridges using capacitive sensors . Click on the green numbers to jump to your application in digital printing or ATM! Feeder system applications Double Sheet ...
Pepperl+Fuchs offers a broad range of sensors and sensor systems for print and paper industry applications ... using ultrasonic sensors has proven itself in the printing, paper, and packaging industry. Printing machine downtime and high repair costs due to double sheet events can now be eliminated due to the ultrasonic series UDC-18GM . Additionally, the UGB ...
The new FieldConnex® fieldbus diagnostic handheld device (FDH-1) from Pepperl+Fuchs greatly simplifies fieldbus installation ... handling represents a real advantage and no special knowledge is required . As a stand-alone solution, no PC is needed . Instead, the device can be easily connected to any fieldbus segment . Testing begins using "single-click operation." Integrated expert ...
Opis: For power supply, installation, and configuration of SC-System modules, various components of the Power Bus as well as an adapter cable are available ... 3 A. One device is able to supply up to 75 modules. By using a number of power feed modules, the power supply can be ensured redundant. ...
Opis: Odbiciowe i refleksyjne czujniki ultradźwiękowe firmy Pepperl+Fuchs zawierają nadajnik i odbiornik w jednej obudowie ... bez powodowania wzajemnych zakłóceń NOWOŚĆ! Niezawodne zabezpieczenie zgodnie z kategorią 3 PL d System ultradźwiękowych czujników USi-safety System czujników ultradźwiękowych USI-Safety stanowi przełom w zastosowaniach bezpieczeństwa . Czujniki można stosować ...
Looking for a manual on a Pepperl+Fuchs product? Start your search here ... Download a Manual Looking for a manual explaining how to setup, install, or program a product? Manuals and model numbers go together! Many of our products have a manual providing detailed information. You can always search for a manual using the ...
Looking for an agency approval or certification on a Pepperl+Fuchs product? Start your search here ... can always search for a model number using the search box located in the upper right corner of our website, or use the products menu to navigate to specific product families and their models. You can also start searching here: ...
Looking for a datasheet or cut sheet on a Pepperl+Fuchs product? Start your search here ... Download a Datasheet Looking for a datasheet or cut sheet on a product? Datasheets and model numbers go together! Each of our products has a datasheet providing technical data. You can always search for a model number using the search box located in ...
41-50/52Ilość elementów na stronie:
Brak efektów wyszukiwań?
Wskazówka: Użyj znaku * przed wpisanym hasłem, zmień hasło zapytania, sprawdź czy hasło jest poprawnie wpisane, albo skontaktuj się bezpośrednio z nami.