Ultrasonic sensor UB500-F54-H3-V1

UB500-F54-H3-V1
  • Separate evaluation
  • Direct detection mode

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Dane techniczne  UB500-F54-H3-V1

Opis produktu
Single head system
General specifications
Sensing range60 ... 500 mm
Dead band0 ... 60 mm 1)
Standard target plate100 mm x 100 mm
Transducer frequencyapprox. 380 kHz
Electrical specifications
Operating voltage10 ... 30 V DC , ripple 10 %SS
No-load supply current≤ 30 mA (typ. 20 mA)
Input
Input type1 pulse input for transmission pulse (clock)
level 0 (active): < 1.5 V
level 1 (inactive): 3.5 V ... +UB
Pulse length5 ... 100 µs (typ. 50 µs) 2)
Pause length≥ 100 x pulse length
Impedance5 kOhm
Output
Output type1 pulse output for echo run time, short-circuit proof
open collector PNP with pulldown resistor = 22 kOhm
level 0 (no echo): -UB
level 1 (echo detected): ≥ (+UB-2 V)
Output current15 mA
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
IEC 60947-5-2:2007
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 4-pin
Degree of protectionIP65
Material
HousingABS
Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam
Mass110 g
Dimensions
Height31 mm
Width105 mm
Length25 mm

Classifications

SystemClasscode
ECLASS 13.027272803
ECLASS 12.027272803
ECLASS 11.027272803
ECLASS 10.0.127272803
ECLASS 9.027272803
ECLASS 8.027272803
ECLASS 5.127272803
ETIM 9.0EC001849
ETIM 8.0EC001849
ETIM 7.0EC001849
ETIM 6.0EC001849
ETIM 5.0EC001847
UNSPSC 12.141111960

Details: UB500-F54-H3-V1

Datasheet: UB500-F54-H3-V1

DatasheetTyp plikuRozmiar pliku
Datasheet UB500-F54-H3-V1PDF177 KB
Fiche de données UB500-F54-H3-V1PDF181 KB
Datenblatt UB500-F54-H3-V1PDF181 KB
Hoja de datos UB500-F54-H3-V1PDF182 KB

Documents: UB500-F54-H3-V1

Instruction leafletsTyp plikuRozmiar pliku
Instruction leaflet / BeipackzettelPDF184 KB

CAD+CAE: UB500-F54-H3-V1

CADTyp plikuRozmiar pliku
CAD 3-D / CAD 3-DSTP140 KB

Approvals+Certificates: UB500-F54-H3-V1

CertificatesTyp plikuRozmiar pliku
Canada USA CSA Ordinary LocationPDF99 KB
Canada USA UL Ordinary LocationLINK---

Produkty powiązane: UB500-F54-H3-V1

Accessories

Female cordset single-ended M12 straight A-coded, 4-pin, PVC cable greyfa
System czujników USi-safety

System czujników ultradźwiękowych USi-safety stanowi przełom w zastosowaniach związanych z bezpieczeństwem. Czujniki można stosować zarówno w trudnych warunkach, w zapylonym środowisku, jak i na zewnątrz.

Firma Pepperl+Fuchs oferuje różne dokumenty do pobrania zawierające informacje na temat czujników ultradźwiękowych.