Wsparcie Czujników Przemysłowych
Wsparcie Ochrony przed wybuchem

IO-Link motor control module ICA-8DIO4M1-G20-IO

ICA-8DIO4M1-G20-IO
  • Inputs for 2- and 3-wire sensors
  • Electronic PNP outputs
  • Connections for DC roller motors
  • Configuration and control via IO-Link
  • Function indicator for motors, inputs and outputs

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Pobierz pełną kartę katalogową w formie pliku PDF:


Dane techniczne  ICA-8DIO4M1-G20-IO

Opis produktu
G20 IO-Link module for digital inputs/outputs, 8 inputs and 8 outputs, 4 connections for roller motors
General specifications
UL File NumberE223772 "For use in NFPA 79 Applications only"
MTBF90 a
Compatible roller motorsInterroll EC310, Interroll EC5000 24V AI (20W / 35W / 50W), Rulmeca BL3, Itoh Denki PM500XK, Itoh Denki PM500XC , PULSEROLLER Senergy-IDC
Indicators/operating means
LED yellow/redIO1 ... IO8: IO-Link status
MOT1 ... MOT4: motor status
Electrical specifications
Auxiliary voltage18 ... 30 VDC PELV Max. 10 A
Current limitation of the supply max. 30 A
For UL: Z-type miniature circuit breaker in accordance with UL 1077, max. 20 A, required
Operating voltage18 ... 30 V DC, PELV
Max. 2.5 A (IO-Link)
Current limitation of the supply max. 4 A
No-load supply current≤ 25 mA
Operating currentmax. 2.5 A
Interface
Interface typeIO-Link
IO-Link revision1.1
Device profileIdentification and Diagnosis - I&D
Process data8 byte inputs (STD/EXT)
6 byte outputs (STD)
18 byte outputs (EXT)
Vendor ID1 (0x0001)
Device IDRev. A:
984066 (0x0F0402) (STD) - default
984065 (0x0F0401) (EXT)
Rev. B:
984066 (0x0F0402) (STD)
984065 (0x0F0401) (EXT)
984070 (0x0F0406) (STD) - default
984069 (0x0F0405) (EXT)
Data transfer rateCOM3 (230.4 kbits/s)
Min. cycle time1.2 ms (STD)
2 ms (EXT)
SIO mode supportno
Compatible master port typeClass A
Input
Number/Type8 Inputs for 3-wire sensors (PNP), DC (IO1 ... IO8)
Supplyfrom IO-Link
Current loading capacity200 mA , overload and short-circuit protected
Input current≤ 5 mA (limited internally)
Switching pointType 3 according to IEC 61131-2
Output 1
Number/Type8 electronic outputs, PNP (IO1 … IO8), overload proof and short-circuit proof
Supplyfrom IO-Link
Current200 mA per output
Voltage≥ (Ue - 1.5 V)
Output 2
Number/Type4 outputs for DC roller motors (MOT1 ... MOT4)
Supplyvia UPWR
Current loading capacity3.5 A (continuous), 5 A (< 2 s), max. 7.5 A (< 0.3 s) per motor
Total current (continuous) max. 10 A per device
Overload protectionFuse 5 A, I2t = 53.7 A2s per motor
Signal levelSpeed: US = 0.3 … 10 V in no-load operation
Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ
Direction of rotation: Digital output PNP
UD low = high resistance
UD high ≥ (UPWR -0.5 V)
Current-carrying capacity 400 mA, overload proof and short-circuit proof
Fault levelMotor fault: Digital input NPN
0 (no error) ≥ 125 µA
1 (error) ≤ 25 µA
Output 3
Number/Type4 electronic outputs, PNP (DIR/OUT1 … DIR/OUT4), overload and short-circuit proof
Supplyvia UPWR
Current400 mA per output
Voltage≥ (UPWR - 0.5 V)
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
EN 55011:2016
Standard conformity
Degree of protectionEN 60529:2000
Fieldbus standardEN 61131-9:2013
InputEN 61131-2:2007
Communication interfaceIEC 61131-9 / IO-Link V1.1.2
Emitted interferenceEN 61000-6-4:2007
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 70 °C (-13 ... 158 °F)
Relative humidity85 % non-condensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks
Vibration resistance0.35 mm / 5 g 5 ... 500 Hz
Pollution degree2
Mechanical specifications
Degree of protectionIP54 according to EN 60529
Connection24 V power (PWR): Piercing technology, black flat cable
IO-Link: M12 round plug connector in accordance with EN 61076-2-101, LM type (4-pin, connector contacts, screw-locking, A-coded)
Female connector: LF type or similar
Inputs/outputs (IO), motors (MOT): M8 round plug connector in accordance with EN 61076-2-104
IO: LF type (4-pin, bushing contacts, screw-locking, A-coded)
Female connector: LM type or similar
MOT: NF type (5-pin, bushing contacts, snap-locking, B-coded)
Female connector: NM type or similar
Mass310 g
Dimensions
Height27.5 mm
Width131.5 mm
Length54 mm
Mounting2 clips with ∅ 8 mm drill hole
The module must be secured to a solid, continuous surface using the two lugs
Cable length1 m (IO-Link)
0.5 m (IO1/2, IO5/6), 0.65 m (IO3/4, IO7/8)
0.5 m (MOT1, MOT3); 0.4 m (MOT2, MOT4)
max. 10 m
NoteThe flat cable routing is designed for 100 actuation cycles

Classifications

SystemClasscode
ECLASS 13.027242604
ECLASS 12.027242604
ECLASS 11.027242604
ECLASS 10.0.127242604
ECLASS 9.027242604
ECLASS 8.027242604
ECLASS 5.127242604
ETIM 9.0EC001597
ETIM 8.0EC001597
ETIM 7.0EC001597
ETIM 6.0EC001597
ETIM 5.0EC001597
UNSPSC 12.132151705

Details: ICA-8DIO4M1-G20-IO

Function

The rollerdrive motor control module ICA-8DIO4M1-G20-IO* is a field module with 8 combined sensor inputs or electronic outputs. The 4 outputs for controlling DC rollerdrive motors are optimized for:

  • Interroll EC310.

  • Interroll EC5000 24V AI (20W / 35W / 50W)

  • Rulmeca BL3

  • Itoh Denki PM500XK

  • Itoh Denki PM500XC

  • PULSEROLLER Senergy-IDC

The compact housing can be mounted directly into support profiles or cable ducts. The power supply U PWR is connectedby piercing technology via the black AS-Interface flat cable. The swiveling flat cable guide locks without tools by a snap-fit.

The combined inputs and outputs and the motor outputs are connected using cable outputs with M8 round connectors. The inputs and outputs have 4-pin female connectors with locking nut, the motor outputs have 5-pin snap-on female connectors. IO-Link is connected using a cable output with M12 4-pin round plug connector.The inputs and outputs are supplied via IO-Link. The motor outputs are supplied via U PWR.

The LEDs IO display the current switching state and as well a fault condition of the combined inputs/outputs. The LEDs M display the operating state of the motors (stop/run/fault).

The module is configured via IO-Link.

Product Documentation: ICA-8DIO4M1-G20-IO

Language Selection:
Brief InstructionsJęzykTyp plikuRozmiar pliku
Instruction leaflet / BeipackzettelALLPDF187 KB
Manuals
Manual ICA-8DIO4M1-G20-IO Extended VersionENGPDF1788 KB
Manual ICA-8DIO4M1-G20-IO Standard VersionENGPDF1800 KB
Parameter Information
IO-Link Parameter Datasheet ICA-8DIO4M1-G20-IO Extended Version / IO-Link Parameter Datasheet ICA-8DIO4M1-G20-IO Extended VersionALLPDF936 KB
IO-Link Parameter Datasheet ICA-8DIO4M1-G20-IO Standard Version / IO-Link Parameter Datasheet ICA-8DIO4M1-G20-IO Standard-VersionALLPDF946 KB

Design / Simulation: ICA-8DIO4M1-G20-IO

Language Selection:
CADJęzykTyp plikuRozmiar pliku
CAD 3-D / CAD 3-DALLSTP3418 KB

Approvals: ICA-8DIO4M1-G20-IO

Language Selection:
CertificatesNr. certyfikatuJęzykTyp plikuRozmiar pliku
IO-Link Manufacturer DeclarationCERT-5779AALLPDF173 KB
US CA ULE223772ALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4980ALLPDF163 KB

Software: ICA-8DIO4M1-G20-IO

Language Selection:
Device Description Files/DriversInformacja o wersjiTyp plikuRozmiar pliku
IODD for ICA-8DIO4M1-G20-IO (EXT) / IODD für ICA-8DIO4M1-G20-IO (EXT)V1.01.000 / 2023-11-02ZIP172 KB
IODD for ICA-8DIO4M1-G20-IO (EXT) Rev. B / IODD für ICA-8DIO4M1-G20-IO (EXT) Rev. BV1.00.000 / 2023-11-02ZIP172 KB
IODD for ICA-8DIO4M1-G20-IO (STD) / IODD für ICA-8DIO4M1-G20-IO (STD)V1.01.000 / 2023-11-02ZIP171 KB
IODD for ICA-8DIO4M1-G20-IO (STD) Rev. B / IODD für ICA-8DIO4M1-G20-IO (STD) Rev. BV1.00.000 / 2023-11-02ZIP172 KB
Software Tools
IO-Link Offline Parameterization Tool / IO-Link Offline-ParametriertoolV1.00.006 / 2022-07-10ZIP96138 KB

Produkty powiązane: ICA-8DIO4M1-G20-IO

Accessories
Mounting aidfa
Zestaw startowy IoT

Podłącz czujniki do chmury i rozpocznij transformację cyfrową, korzystając z nowych zestawów startowych IIoT