Fieldbus Diagnostic Handheld, Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, Europepa
Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa
Basic monitoring for power supply output and health, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa
Fiber optic sensor for glass fiber optic and plastic fiber optic, slim design, range up to 450 mm, red light, 3 response times available, self-diagnostic function, light/dark on, push-pull output, fixed cable with M8 plug, Basic line for DIN rail installation, Sleek design, 3 response times selectable, High switching frequency, Self diagnosis functionfa
Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa
Enlcosure leakage sensor for operation with FOUNDATION Fieldbus and PROFIBUS PA, Indication via LED and Advanced Diagnostics, Intrinsically safe, FISCO or Entity, For instrument or device coupler, Fits inside terminal compartment, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, USA, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa
Fieldbus Power Hub, Advanced Diagnostic Module with Relay Output
Diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa
1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for de-energized to safe function, Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC/EN 61508, Up to PL e acc. to EN/ISO 13849, Housing width: 20 mm, Number of channels: 1-channel, Diagnostics function, Line fault transparency, DTS function (de-energized to safe), Safety Integrity Level (SIL): SIL 3pa
1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC, Relay contact output for de-energized to safe function, Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC/EN 61508, Up to PL e acc. to EN/ISO 13849, Housing width: 20 mm, Number of channels: 1-channel, Diagnostics function, Line fault transparency, DTS function (de-energized to safe), Safety Integrity Level (SIL): SIL 3pa
1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Diagnostics function, Line fault transparency, ETS function (energized to safe), Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 26.4 V DCpa
Not available for purchase: Sensing range up to 10 m, 3-radial design, Beam spacing 400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputs, Connection: M16 cable gland , terminal compartment with cage-terminals, M12-connector for emitterfa
Not available for purchase: Sensing range up to 10 m, 3-radial design, Beam spacing 400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Not available for purchase: Sensing range up to 10 m, 3-radial design, Beam spacing 400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 relay outputs, force-guided NO-contactfa
Not available for purchase: Sensing range up to 10 m, 3-radial design, Beam spacing 400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 relay outputs, force-guided NO-contact, Connection: M16 cable gland , terminal compartment with cage-terminals, M12-connector for emitterfa
Not available for purchase: Sensing range up to 10 m, 4-radial design, Beam spacing 300 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputs, Connection: M16 cable gland , terminal compartment with cage-terminals, M12-connector for emitterfa
Not available for purchase: Sensing range up to 10 m, 4-radial design, Beam spacing 300 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Not available for purchase: Sensing range up to 10 m, 4-radial design, Beam spacing 300 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 relay outputs, force-guided NO-contactfa
Not available for purchase: Sensing range up to 10 m, 4-radial design, Beam spacing 300 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 relay outputs, force-guided NO-contact, Connection: M16 cable gland , terminal compartment with cage-terminals, M12-connector for emitterfa
Not available for purchase: Sensing range up to 30 m, 2-radial design, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputs, Connection: M16 cable gland , terminal compartment with cage-terminals, M12-connector for emitterfa
Not available for purchase: Sensing range up to 30 m, 2-radial design, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa