Nedostupné pro prodej: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Nedostupné pro prodej: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Nedostupné pro prodej: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Nedostupné pro prodej: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Nedostupné pro prodej: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Nedostupné pro prodej: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Nedostupné pro prodej: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Nedostupné pro prodej: Diffuse sensor with measurement core technology, large housing design, background suppression and 3 more adjustable operating modes, IO-Link interface, 800 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable, Cost-optimized series for standard tasks, Sensing-by-ranging functionality, IO-Link interface for service and process data, PowerBeam transmitter LED, Large adjustment range can be precisely definedfa
The WILSEN platform offers three LoRa-based, battery-powered sensor solutions for a wide range of M+O applications ... transmitted directly to message queues in the IoT platforms TTN (The Things Network) and ChirpStack (v3 and v4) via the Network API Key. Alternatively, the devices can be parameterized directly on site via Bluetooth® LE using a mobile device app for Android or ...
Get an overview of Pepperl+Fuchs' broad portfolio of HMI systems for process industries ... hazardous areas. VisuNet RM Shell 6 VisuNet RM Shell 6 is the latest generation firmware for VisuNet Remote Monitors and Box Thin Clients from Pepperl+Fuchs. Using standard Ethernet technology , the software communicates with the process control system or ...
Případ použití „řešení problémů“ – Inteligentní řešení pro aplikace IIoT založené na průmyslové komunikaci v prostředích s nebezpečím výbuchu ... via the HART communication protocol . In the event of a planned plant shutdown , the valve can be replaced by a technician using work order management. The technician can effectively schedule the installation into his route. An image documentation of ...
Senzory používané v mobilním zařízení musí spolehlivě fungovat v náročných podmínkách, ať už na silnici nebo v terénu Společnost Pepperl+Fuchs nabízí široké portfolio senzorových řešení pro mobilní s ... , nebo sleduje oblast. Miniaturní senzorová jednotka, která je oddělená od řídicího rozhraní, umožňuje používat systém USi-safety i ve stísněných instalacích. Zabránění kolizím Mobilní stroje, jako jsou rypadla, poskytují často značně omezený výhled dozadu ...
During the manufacturing of battery modules for electric vehicles, several prismatic battery cells are welded together To do this, the cells must be positioned correctly The VOS 2-D universal vision ... data should also be fully documented. The Solution VOS5000 in C-Mount Version with External Bar Lighting With the VOS 2-D universal vision sensor, all tasks can be completed using a single device. In the C-mount version VOS5000 , the device can be ...
6-10/43Položek na stránku::
Nic nenalezeno?
Rada: Použijte tento znak * před začátkem vyhledávání, upravte vyhledáváný text, zkontrolujte pravopis, nebo nás pro další dotazy kontaktujte.