Niedostępne w sprzedaży: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Niedostępne w sprzedaży: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Niedostępne w sprzedaży: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Niedostępne w sprzedaży: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Niedostępne w sprzedaży: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Niedostępne w sprzedaży: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Niedostępne w sprzedaży: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Niedostępne w sprzedaży: Diffuse sensor with measurement core technology, large housing design, background suppression and 3 more adjustable operating modes, IO-Link interface, 800 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable, Cost-optimized series for standard tasks, Sensing-by-ranging functionality, IO-Link interface for service and process data, PowerBeam transmitter LED, Large adjustment range can be precisely definedfa
Technologia SmartRunner pozwala firmie Pepperl+Fuchs połączyć dwa zaawansowane rozwiązania w produkt, który można stosować w wymagających zadaniach wykrywania ... small housing of 55 × 38 × 85 mm (L × W × H) allows easy mechanical integration, even in confined installation conditions. By using a deviation mirror, a virtual base length extension is realized, which makes the laser profile especially compact. The ...
Opis: Innovative measurement devices and other tools for maintenance work in hazardous areas ... indicates that the magnet is activated. The Magnet-Ex 12 comes with an integral test magnet that is securely fitted in such a way that it cannot be easily lost. Using this magnet, tests can be carried out to establish the working state of both unit and ...
Opis: Based on light section technology, the SmartRunner Explorer provides the innovative combination of height profile and 2-D image data in one sensor Discover the versatile sensor for profile dete ... applications by using raw data Highlights Unique combination of height profile and 2-D image output in one sensor Raw data output for flexible application implementation Easy integration via Ethernet TCP/IP and included DLL Przykłady zastosowań Precyzyjny ...
VisuNet RM Shell 5 to oprogramowanie sprzętowe najnowszej generacji przeznaczone do zdalnych monitorów VisuNet ... do wymogów danego zastosowania. Sprostaj przyszłym potrzebom With the introduction of VisuNet RM Shell 5, Pepperl+Fuchs presents the next generation firmware for VisuNet Remote Monitors that meets the demands of tomorrow in every detail. Using standard ...
Zapoznaj się z bazą wiedzy firmy Pepperl+Fuchs, aby dowiedzieć się więcej o rodzajach obudów czujników indukcyjnych ... wymagań termicznych. Właściwości: Odporność na wysokie temperatury, Odporność na zgrzewanie, Odporność na działanie paliwa Niska palność Bez halogenów Odporność na hydrolizę Odporność na działanie oleju Usieciowane cząsteczki Typowe zastosowania: przemysł ...
Firma Pepperl+Fuchs oferuje czujnik ultradźwiękowy do bezpiecznej obsługi systemów transportu automatycznego w szpitalach ... wykrywanie obszaru głowy i ramion personelu znajdującego się w pasie ruchu, aby zapobiec obrażeniom w wyniku kolizji. Rozwiązanie System czujników ultradźwiękowych USi®-safety, to system, który zapewnia bezpieczeństwo personelu. Czujnik, który niezawodnie ...
Firma Pepperl+Fuchs oferuje system czujników ultradźwiękowych zgodny z normą EN ISO 13849 kategorii 3 PL d do bezpiecznej nawigacji pojazdów AGV w magazynach ... środowiskowe , takie jak kurz, brud i wilgoć. Rozwiązanie USi®-safety to jedyny bezpieczny system czujników ultradźwiękowych zgodny z normą EN ISO 13849 kategorii 3 PL d. Umożliwia on niezawodne monitorowanie przestrzeni trójwymiarowych , dzięki czemu idealnie ...
Opis: Czujniki do monitorowania obszaru Pepperl+Fuchs, takie jak SmartRunner Detector, zostały zoptymalizowane pod kątem wysokiej precyzji monitorowania ... set as needed using Data Matrix control codes—all without the use of a PC. The laser profile sensor can also be quickly and easily aligned with natural objects such as a wall. This eliminates the additional effort of alignment as well as duplicate ...
Uniwersalny model Ex-Handy 10 jest opracowanym przez nas rozwiązaniem typu feature phone, wyposażonym w baterię o dużej pojemności i obsługiwanym zarówno za pomocą przycisków, jak i ekranu dotykowego ... products’ software and configurations and manage them using a remote firmware solution . It also enables customers to react quickly to the changing requirements of their individual applications by carrying out necessary adjustments. This saves time ...
Odkryj naszą kompleksową ofertę dla przemysłu motoryzacyjnego — od niezawodnego pozycjonowania i identyfikacji po zapewnienie płynności procesów w systemach przenośników i zastosowaniach o kluczowym z ... sensor system is breaking new ground for safety applications—whether in challenging, dusty environments or in outdoor areas. Machines and vehicles can be reliably protected using state-of-the-art ultrasonic technology and all of the advantages this brings ...
21-30/52Ilość elementów na stronie:
Brak efektów wyszukiwań?
Wskazówka: Użyj znaku * przed wpisanym hasłem, zmień hasło zapytania, sprawdź czy hasło jest poprawnie wpisane, albo skontaktuj się bezpośrednio z nami.